47 research outputs found

    Sensor array and gas chromatographic detection of the blood serum volatolomic signature of COVID-19

    Get PDF
    Volatolomics is gaining consideration as a viable approach to diagnose several diseases, and it also shows promising results to discriminate COVID-19 patients via breath analysis. This paper extends the study of the relationship between volatile compounds (VOCs) and COVID-19 to blood serum. Blood samples were collected from subjects recruited at the emergency department of a large public hospital. The VOCs were analyzed with a gas chromatography mass spectrometer (GC/MS). GC/MS data show that in more than 100 different VOCs, the pattern of abundances of 17 compounds identifies COVID-19 from non-COVID with an accuracy of 89% (sensitivity 94% and specificity 83%). GC/MS analysis was complemented by an array of gas sensors whose data achieved an accuracy of 89% (sensitivity 94% and specificity 80%)

    analysis of exhaled breath fingerprints and volatile organic compounds in copd

    Get PDF
    Exhaled air contains many volatile organic compounds (VOCs) produced during human metabolic processes, in both healthy and pathological conditions. Analysis of breath allows studying the modifications of the profile of the exhaled VOCs due to different disease states, including chronic obstructive pulmonary disease (COPD). The early diagnosis of COPD is complicated and the identification of specific metabolic profiles of exhaled air may provide useful indication to better identify the disease. The aim of our study was to characterize the specific exhaled VOCs by means of the electronic nose and by solid phase micro-extraction associated to gas chromatography–mass spectrometry (SPME GC-MS). Exhaled air was collected and measured in 34 subjects, 7 healthy and 27 former smokers affected by COPD (GOLD 1–4). The signals of the electronic nose sensors were higher in COPD patients with respect to controls, and allowed to accurately classify the studied subjects in healthy or COPD. GC-MS analysis identified 37 VOCs, nine of which were significantly correlated with COPD. In particular the concentration of two of these were positively correlated whereas seven were negatively correlated with COPD. The partial least squares discriminant analysis (PLS-DA) carried out with these nine VOCs produced a significant predictive model of disease. This study shows that COPD patients exhibit qualitative and quantitative differences in the chemical compositions of exhale. These differences are detectable both by the GC-MS and the six-sensor e-nose. The use of electronic nose may represent a suitable, non-invasive diagnostic tool for characterization of COPD

    Differential Detection of Potentially Hazardous Fusarium Species in Wheat Grains by an Electronic Nose

    Get PDF
    Fungal infestation on wheat is an increasingly grave nutritional problem in many countries worldwide. Fusarium species are especially harmful pathogens due to their toxic metabolites. In this work we studied volatile compounds released by F. cerealis, F. graminearum, F. culmorum and F. redolens using SPME-GC/MS. By using an electronic nose we were able to differentiate between infected and non-infected wheat grains in the post-harvest chain. Our electronic nose was capable of distinguishing between four wheat Fusaria species with an accuracy higher than 80%

    Corroles-Porphyrins: A Teamwork for Gas Sensor Arrays

    No full text
    Porphyrins provide an excellent material for chemical sensors, and they have been used for sensing species both in air and solution. In the gas phase, the broad selectivity of porphyrins is largely dependant on molecular features, such as the metal ion complexed at the core of the aromatic ring and the peripheral substituents. Although these features have been largely exploited to design gas sensor arrays, so far, little attention has been devoted to modify the sensing properties of these macrocycles by variation of the molecular aromatic ring. In this paper, the gas sensing properties of a porphyrin analog, the corrole, are studied in comparison with those of the parent porphyrin. Results show that changes in the aromatic ring have important consequences on the sensitivity and selectivity of the sensors and that porphyrins and corroles can positively cooperate to enhance the performance of sensor arrays

    Aspergillus Species Discrimination Using a Gas Sensor Array

    No full text
    The efficiency of electronic noses in detecting and identifying microorganisms has been proven by several studies. Since volatile compounds change with the growth of colonies, the identification of strains is highly dependent on the growing conditions. In this paper, the effects of growth were investigated with different species of Aspergillus, which is one of the most studied microorganisms because of its implications in environmental and food safety. For this purpose, we used an electronic nose previously utilized for volatilome detection applications and based on eight porphyrins-functionalized quartz microbalances. The volatile organic compounds (VOCs) released by cultured fungi were measured at 3, 5, and 10 days after the incubation. The signals from the sensors showed that the pattern of VOCs evolve with time. In particular, the separation between the three studied strains progressively decreases with time. The three strains could still be identified despite the influence of culture time. Linear Discriminant Analysis (LDA) showed an overall accuracy of 88% and 71% in the training and test sets, respectively. These results indicate that the presence of microorganisms is detectable with respect to background, however, the difference between the strains changes with the incubation time

    Sensors for Lung Cancer Diagnosis

    No full text
    The positive outcome of lung cancer treatment is strongly related to the earliness of the diagnosis. Thus, there is a strong requirement for technologies that could provide an early detection of cancer. The concept of early diagnosis is immediately extended to large population screening, and then, it is strongly related to non-invasiveness and low cost. Sensor technology takes advantage of the microelectronics revolution, and then, it promises to develop devices sufficiently sensitive to detect lung cancer biomarkers. A number of biosensors for the detection of cancer-related proteins have been demonstrated in recent years. At the same time, the interest is growing towards the analysis of volatile metabolites that could be measured directly from the breath. In this paper, a review of the state-of-the-art of biosensors and volatile compound sensors is presented

    An exploration of the metal dependent selectivity of a metalloporphyrins coated quartz microbalances array

    No full text
    Several studies in the last two decades have demonstrated that metalloporphyrins coated quartz microbalances can be fruitfully used in many diverse applications, spanning from medical diagnosis to environmental control. This large versatility is due to the combination of the flexibility of metalloporphyrins molecular design with the independence of the quartz microbalance signal from the interaction mechanisms. The nature of the metal atom in the metalloporphyrins is often indicated as one of the most effective tools to design differently selective sensors. However, the properties of sensors are also strongly affected by the characteristics of the transducer. In this paper, the role of the metal atom is investigated studying the response, to various volatile compounds, of six quartz microbalance sensors that are based on the same porphyrin but with different metals. Results show that, since quartz microbalances (QMB) transducers can sense all the interactions between porphyrin and volatile compounds, the metal ion does not completely determine the sensor behaviour. Rather, the sensors based on the same molecular ring but with different metal ions show a non negligible common behaviour. However, even if limited, the different metals still confer peculiar properties to the sensors and might drive the sensor array identification of the pool of tested volatile compounds. © 2016 by the authors; licensee MDPI, Basel, Switzerland

    An Exploration of the Metal Dependent Selectivity of a Metalloporphyrins Coated Quartz Microbalances Array

    No full text
    Several studies in the last two decades have demonstrated that metalloporphyrins coated quartz microbalances can be fruitfully used in many diverse applications, spanning from medical diagnosis to environmental control. This large versatility is due to the combination of the flexibility of metalloporphyrins molecular design with the independence of the quartz microbalance signal from the interaction mechanisms. The nature of the metal atom in the metalloporphyrins is often indicated as one of the most effective tools to design differently selective sensors. However, the properties of sensors are also strongly affected by the characteristics of the transducer. In this paper, the role of the metal atom is investigated studying the response, to various volatile compounds, of six quartz microbalance sensors that are based on the same porphyrin but with different metals. Results show that, since quartz microbalances (QMB) transducers can sense all the interactions between porphyrin and volatile compounds, the metal ion does not completely determine the sensor behaviour. Rather, the sensors based on the same molecular ring but with different metal ions show a non-negligible common behaviour. However, even if limited, the different metals still confer peculiar properties to the sensors and might drive the sensor array identification of the pool of tested volatile compounds

    Sensing mechanisms of supramolecular porphyrin aggregates: a teamwork task for the detection of gaseous analytes

    No full text
    7nonenoneNardis S; POMARICO G; Tortora L; Capuano R; D’Amico A; Di Natale C; Paolesse RNardis, S; Pomarico, G; Tortora, L; Capuano, R; D’Amico, A; Di Natale, C; Paolesse,
    corecore