769 research outputs found

    Resonant effects in a SQUID qubit subjected to non adiabatic changes

    Get PDF
    By quickly modifying the shape of the effective potential of a double SQUID flux qubit from a single-well to a double-well condition, we experimentally observe an anomalous behavior, namely an alternance of resonance peaks, in the probability to find the qubit in a given flux state. The occurrence of Landau-Zener transitions as well as resonant tunneling between degenerate levels in the two wells may be invoked to partially justify the experimental results. A quantum simulation of the time evolution of the system indeed suggests that the observed anomalous behavior can be imputable to quantum coherence effects. The interplay among all these mechanisms has a practical implication for quantum computing purposes, giving a direct measurement of the limits on the sweeping rates possible for a correct manipulation of the qubit state by means of fast flux pulses, avoiding transitions to non-computational states.Comment: 6 pages and 6 figures. The paper, as it is, has been accepted for publication on PRB on March 201

    Microwave-induced thermal escape in Josephson junctions

    Full text link
    We investigate, by experiments and numerical simulations, thermal activation processes of Josephson tunnel junctions in the presence of microwave radiation. When the applied signal resonates with the Josephson plasma frequency oscillations, the switching current may become multi-valued in a temperature range far exceeding the classical to quantum crossover temperature. Plots of the switching currents traced as a function of the applied signal frequency show very good agreement with the functional forms expected from Josephson plasma frequency dependencies on the bias current. Throughout, numerical simulations of the corresponding thermally driven classical Josephson junction model show very good agreement with the experimental data.Comment: 10 pages and 4 figure

    Venous Pulse Wave Velocity variation in response to a simulated fluid challenge in healthy subjects

    Get PDF
    Purpose: The evaluation of a mini or simulated fluid challenge is still a complex and open issue in the clinical setting and it is of paramount significance for the fluid therapy optimization. We here investigated the capacity of a new hemodynamic parameter, the venous Pulse Wave Velocity (vPWV), to detect the effect of passive leg raising (PLR). Materials and methods: In 15 healthy volunteers (7 M, 8 F, age 26 ± 3) venous pressure pulses were elicited by pneumatic compressions of the left hand and proximally detected by ultrasound for calculation of the vPWV. We also non-invasively measured the basilic vein (BV) cross-sectional perimeter, and peripheral venous pressure (PVP). The PLR manoeuvre was performed twice to evaluate reliability of the assessment. Results: The PLR had an overall statistically significant effect on the entire set of variables (MANOVA, p < 0.05): vPWV increased from 2.11 ± 0.46 to 2.30 ± 0.47 m/s (p = 0.01; average increase: 10%). This effect was transient and dropped below 5% after about 3 min. A significant increase was also exhibited by BV size and PVP. In consecutive measurements vPWV showed little intra-subject variability (CoV = 8%) and good reliability (ICC = 0.87). Finally, the vPWV responses to the two PLRs exhibited good agreement (paired T-test: p = 0.96), and moderate reliability (ICC = 0.57). Conclusion: These results demonstrated that vPWV can be non-invasively, objectively and reliably measured in healthy subjects and that it is adequate to detect small pressure/volume variations, as induced by PLR-from-supine. These characteristics make it suitable for clinical applications

    Superconducting tunable flux qubit with direct readout scheme

    Full text link
    We describe a simple and efficient scheme for the readout of a tunable flux qubit, and present preliminary experimental tests for the preparation, manipulation and final readout of the qubit state, performed in incoherent regime at liquid Helium temperature. The tunable flux qubit is realized by a double SQUID with an extra Josephson junction inserted in the large superconducting loop, and the readout is performed by applying a current ramp to the junction and recording the value for which there is a voltage response, depending on the qubit state. This preliminary work indicates the feasibility and efficiency of the scheme.Comment: 10 pages, 5 figure

    Ten years of lateral flow immunoassay technique applications: Trends, challenges and future perspectives

    Get PDF
    The Lateral Flow Immunoassay (LFIA) is by far one of the most successful analytical platforms to perform the on-site detection of target substances. LFIA can be considered as a sort of lab-in-a-hand and, together with other point-of-need tests, has represented a paradigm shift from sample-to-lab to lab-to-sample aiming to improve decision making and turnaround time. The features of LFIAs made them a very attractive tool in clinical diagnostic where they can improve patient care by enabling more prompt diagnosis and treatment decisions. The rapidity, simplicity, relative cost-effectiveness, and the possibility to be used by nonskilled personnel contributed to the wide acceptance of LFIAs. As a consequence, from the detection of molecules, organisms, and (bio)markers for clinical purposes, the LFIA application has been rapidly extended to other fields, including food and feed safety, veterinary medicine, environmental control, and many others. This review aims to provide readers with a 10-years overview of applications, outlining the trends for the main application fields and the relative compounded annual growth rates. Moreover, future perspectives and challenges are discussed

    Return current in hysteretic Josephson junctions: Experimental distribution in the thermal activation regime

    Get PDF
    We present an experimental study on the retrapping process of a hysteretic, high-quality Josephson junction; namely, we have measured the distribution of the values at which the junction switches back from the voltage state to the zero-voltage state, as a function of the applied magnetic field. While the opposite process (escape from the zero-voltage state) has been extensively studied in the past, both from the theoretical and the experimental point of view, little is found in the literature on the retrapping process. In terms of the tilted washboard potential, the process corresponds to the retrapping from the running state to a locked state in a potential well. The interest of the measurements is in the fact that the value of the return current can be directly related to the dissipation in the junction. While the deterministic behavior, experimentally measured through the I–V curve, appears to be in agreement with the theoretical predictions, even in minor details, the statistical behavior is strongly different from what is expected. The disagreement is found even in zero-applied magnetic field and it cannot be attributed to external noise in the system. From the experimental statistical properties, we find values for the effective dissipation much lower than those obtained from the deterministic curves, a result which could be of interest in experiments on the observation of macroscopic quantum phenomena

    NanoMIP-based solid phase extraction of fluoroquinolones from human urine: A proof-of-concept study

    Get PDF
    NanoMIPs that are prepared by solid phase synthesis have proven to be very versatile, but to date only limited attention has been paid to their use in solid phase extraction. Thus, since nanoMIPs show close similarities, in terms of binding behavior, to antibodies, it seems relevant to verify if it is possible to use them as mimics of the natural antibodies that are used in immunoextraction methods. As a proof-of-concept, we considered prepared nanoMIPs against fluoroquinolone ciprofloxacin. Several nanoMIPs were prepared in water with polymerization mixtures of different compositions. The polymer with the highest affinity towards ciprofloxacin was then grafted onto a solid support and used to set up a solid phase extraction–HPLC method with fluorescence detection, for the determination of fluoroquinolones in human urine. The method resulted in successful selection for the fluoroquinolone antibiotics, such that the nanoMIPs were suitable for direct extraction of the antibiotics from the urine samples at the µg mL−1 level. They required no preliminary treatment, except for a 1 + 9 (v/v) dilution with a buffer of pH 4.5 and they had good analyte recovery rates; up to 85% with precision in the range of 3 to 4.5%, without interference from the matrix. These experimental results demonstrate, for the first time, the feasibility of the use of nanoMIPs to develop solid phase extraction methods
    • …
    corecore