    Load calculations of radiant cooling systems for sizing the plant

    Get PDF
    AbstractThe aim of this study was, by using a building simulation software, to prove that a radiant cooling system should not be sized based on the maximum cooling load but at a lower value. For that reason six radiant cooling models were simulated with two control principles using 100%, 70% and 50% of the maximum cooling load. It was concluded that all tested systems were able to provide an acceptable thermal environment even when the 50% of the maximum cooling load was used. From all the simulated systems the one that performed the best under both control principles was the ESCS ceiling system. Finally it was proved that ventilation systems should be sized based on the maximum cooling load

    Experimental study of energy performance in low-temperature hydronic heating systems

    Get PDF
    Energy consumption, thermal environment and environmental impacts were analytically and experimentally studied for different types of heat emitters. The heat emitters studied were conventional radiator, ventilation radiator, and floor heating with medium-, low-, and very-low-temperature supply, respectively. The ventilation system in the lab room was a mechanical exhaust ventilation system that provided one air change per hour of fresh air through the opening in the external wall with a constant temperature of 5 °C, which is the mean winter temperature in Copenhagen. The parameters studied in the climate chamber were supply and return water temperature from the heat emitters, indoor temperature, and heat emitter surface temperature. Experiments showed that the mean supply water temperature for floor heating was the lowest, i.e. 30 °C, but it was close to the ventilation radiator, i.e. 33 °C. The supply water temperature in all measurements for conventional radiator was significantly higher than ventilation radiator and floor heating; namely, 45 °C. Experimental results indicated that the mean indoor temperature was close to the acceptable level of 22 °C in all cases. For energy calculations, it was assumed that all heat emitters were connected to a ground-source heat pump. Analytical calculations showed that using ventilation radiator and floor heating instead of conventional radiator resulted in a saving of 17% and 22% in heat pump's electricity consumption, respectively. This would reduce the CO2 emission from the building's heating system by 21 % for the floor heating and by 18% for the ventilation radiator compared to the conventional radiator.QC 20160128</p

    Laboratory study of subjective perceptions to low temperature heating systems with exhaust ventilation in Nordic countries

    Get PDF
    Given the global trends of rising energy demand and the increasing utilization of low-grade renewable energy, low-temperature heating systems can play key roles in improving building energy efficiency while providing a comfortable indoor environment. To meet the need to retrofit existing buildings in Nordic countries for greater energy efficiency, this study focused on human subjects’ thermal sensation, thermal comfort, thermal acceptability, draft acceptability, and perceived air quality when three low-temperatureheating systems were used: conventional radiator, ventilation radiator, or floor heating with exhaust ventilation. Human subject tests were carried out in the climate chamber at the Technical University of Denmark. In total, 24 human subjects, 12 females and 12 males, participated in the tests during the winter season. The results show that no significant differences in thermal sensation and thermal comfort between the three heating systems. Ventilation radiator promised a comfortable indoor environment with a decreased watersupply temperature and floor heating with exhaust ventilation can provide a basic thermal comfort level. Thermal acceptability and draft acceptability show variations in different heating systems. Gender has significant influences on thermal sensation, draft acceptability, and preference of clo values. Personal thermal preference is observed between males and females. The males prefer to dress lighter than the females, but both can get the same thermal comfort level. It is concluded that low-temperature heating systems using exhaust air ventilation are a potentially solution when buildings are being retrofitted for improved energy efficiency and comfort of the occupants
    corecore