7,306 research outputs found
Monolithic Pixel Sensors in Deep-Submicron SOI Technology
Monolithic pixel sensors for charged particle detection and imaging
applications have been designed and fabricated using commercially available,
deep-submicron Silicon-On-Insulator (SOI) processes, which insulate a thin
layer of integrated full CMOS electronics from a high-resistivity substrate by
means of a buried oxide. The substrate is contacted from the electronics layer
through vias etched in the buried oxide, allowing pixel implanting and reverse
biasing. This paper summarizes the performances achieved with a first prototype
manufactured in the OKI 0.15 micrometer FD-SOI process, featuring analog and
digital pixels on a 10 micrometer pitch. The design and preliminary results on
the analog section of a second prototype manufactured in the OKI 0.20
micrometer FD-SOI process are briefly discussed.Comment: Proceedings of the PIXEL 2008 International Workshop, FNAL, Batavia,
IL, 23-26 September 2008. Submitted to JINST - Journal of Instrumentatio
Electron-Positron Annihilation into Hadron-Antihadron Pairs
The reactions of electron-positron to nucleon-antinucleon pairs are studied
in a non-perturbative quark model. The work suggests that the two-step process,
in which the primary quark-antiquark pair forms first a vector meson which in
turn decays into a hadron pair, is dominant over the one-step process in which
the primary quark-antiquark pair is directly dressed by additional
quark-antiquark pairs to form a hadron pair. To reproduce the experimental data
of the reactions of electron-positron to proton-antiproton and
electron-positron to neutron-antineutron a D-wave omega-like vector meson with
a mass of around 2 GeV has to be introduced.Comment: 15 pages, 6 figure
On Electron-Positron Annihilation into Nucleon-Antinucleon Pairs
We discuss the puzzling experimental results on baryon-antibaryon production
in e+e- annihilation close to the threshold, in particular the fact that
sigma(e+e- --> nbar n) >~ sigma(e+e- --> pbar p). We discuss an interpretation
in terms of a two-step process, via an intermediate coherent isovector state
serving as an intermediary between e+e- and the baryon-antibaryon system. We
provide evidence that the isovector channel dominates both e+e- --> pions and
from Nbar N annihilation at rest, and show that the observed ratio of
sigma(e+e- --> nbar n)/sigma(e+e- --> pbarp p) can be understood quantitatively
in this picture.Comment: 13 pages, 4 figure
Detection of Cherenkov light from air showers with Geiger-APDs
We have detected Cherenkov light from air showers with Geiger-mode APDs
(G-APDs). G-APDs are novel semiconductor photon-detectors, which offer several
advantages compared to conventional photomultiplier tubes in the field of
ground-based gamma-ray astronomy. In a field test with the MAGIC telescope we
have tested the efficiency of a G-APD / light catcher setup to detect Cherenkov
light from air showers. We estimate a detection efficiency, which is 60% higher
than the efficiency of a MAGIC camera pixel. Ambient temperature dark count
rates of the tested G-APDs are below the rates of the night sky light
background. According to these recent tests G-APDs promise a major progress in
ground-based gamma-ray astronomy.Comment: 4 pages, 5 figures, to appear in the proceedings of the 30th
International Cosmic Ray Conference, Merida, July 200
Electromagnetic form factors in the J/\psi mass region: The case in favor of additional resonances
Using the results of our recent analysis of e^+e^- annihilation, we plot the
curves for the diagonal and transition form factors of light hadrons in the
time-like region up to the production threshold of an open charm quantum
number. The comparison with existing data on the decays of J/\psi into such
hadrons shows that some new resonance structures may be present in the mass
range between 2 GeVand the J/\psi mass. Searching them may help in a better
understanding of the mass spectrum in both the simple and a more sophisticated
quark models, and in revealing the details of the three-gluon mechanism of the
OZI rule breaking in K\bar K channel.Comment: Formulas are added, typo is corrected, the text is rearranged.
Replaced to match the version accepted in Phys Rev
Dispersion-theoretical analysis of the nucleon electromagnetic form factors: Inclusion of time-like data
We update a recent dispersion--theoretical fit to the nucleon electromagnetic
form factors by including the existing data in the time--like region. We show
that while the time--like data for the proton can be described consistently
with the existing world space--like data, this is not the case for the neutron.
Another measurement of the process is called for. We
furthermore sharpen the previous estimate of the separation between the
perturbative and the non--perturbative regime, which is characterized by a
scale parameter GeV.Comment: 7 pp, LaTeX, uses epsf, 2 figures in separate file, four data points
changed, slight changes in the fits, conclusions unchange
LNL irradiation facilities for radiation damage studies on electronic devices
In this paper we will review the wide range of irradiation facilities installed at the INFN Legnaro National Laboratories and routinely used for radiation damage studies on silicon detectors, electronic components and systems. The SIRAD irradiation facility, dedicated to Single Event Effect (SEE) and bulk damage studies, is installed at the 14MV Tandem XTU accelerator and can deliver ion beams from H up to Au in the energy range from 28MeV to 300 MeV. An Ion Electron Emission Microscope, also installed at SIRAD, allows SEE testing with micrometric sensitivity. For total dose tests, two facilities are presently available: an X-rays source and a 60Co γ-ray source. The 7MV Van de Graaff CN accelerator provides 1H beams in the energy range 2–7MeV and currents up to few μA for both total dose and bulk damage studies. At this facility, very high dose rates (up to ∼100 krad/s (SiO2)) can be achieved. Finally, also neutron beams are available,
produced at the CN accelerator, by the reaction d + Be ⇒ n+B
Total dose effects on deep-submicron SOI technology for Monolithic Pixel Sensor development
We developed and characterized Monolithic pixel detectors in deep-submicron Fully Depleted (FD) Silicon On Insulator (SOI) technology. This paper presents the first studies of total dose effects from ionizing radiation performed on single transistor test structures. This work shows how the substrate bias condition during irradiation heavily affects the resulting radiation damage
Isoscalar resonances with J^{PC}=1^{--} in e^+e^-annihilation
The analysis of the vector isoscalar excitations in the energy range between
1 and 2 GeV of the annihilation is presented for the final states
, , , and
. The effects of both the resonance mixing and the
successive opening of multiparticle channels, with the energy dependent partial
widths, are taken into account. The work extends our previous analysis
hep-ph/9609216 of the vector isovector excitations and is aimed to compare the
existing data with the predictions of the model. It is shown that
this hypothesis does not contradict the data.Comment: 16 pages, revtex, 6 ps figures. Clarifying remarks, a table, and
references are added. Accepted in Phys. Rev.
Precise method for the determination of the neutron electric form factor based on a relativistic analysis of the process $d(e,e'n)p
We generalize the recoil polarization method for the determination of the
proton form factor to the case of the disintegration of vector polarized
deuterons by longitudinally polarized electrons, . We
suggest to measure for this reaction, in the kinematics of quasi-elastic
-scattering, the ratio of the asymmetries induced by the
- and -components of the deuteron vector polarization. In the framework
of the relativistic impulse approximation the ratio is sensitive to
in a wide interval of momentum transfer squared, whereas it depends
weakly on the details of the -interaction and on the choice of the deuteron
wave function. Moreover, in the range 1.5 GeV, the ratio
shows a smooth dependence on , making the analysis simpler.Comment: 7 pages, 4 figs, 1 tabl
- …