6,964 research outputs found
Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented
Modified POF Sensor for Gaseous Hydrogen Fluoride Monitoring in the Presence of Ionizing Radiations
This paper describes the development of a sensor designed to detect low concentrations of hydrogen fluoride (HF) in gas mixtures. The sensor employs a plastic optical fiber (POF) covered with a thin layer of glass- like material. HF attacks the glass and alters the fiber transmission capability so that the detection simply requires a LED and a photodiode. The coated POF is obtained by means of low-pressure plasma-enhanced chemical vapor deposition that allows the glass-like film to be deposited at low temperature without damaging the fiber core. The developed sensor will be installed in the recirculation gas system of the resistive plate chamber muon detector of the Compact Muon Solenoid experiment at the Large Hadron Collider accelerator of the European Organization for Nuclear Research (CERN
Fiber Bragg Grating sensors for deformation monitoring of GEM foils in HEP detectors
Fiber Bragg Grating (FBG) sensors have been so far mainly used in high energy
physics (HEP) as high precision positioning and re-positioning sensors and as
low cost, easy to mount, radiation hard and low space- consuming temperature
and humidity devices. FBGs are also commonly used for very precise strain
measurements. In this work we present a novel use of FBGs as flatness and
mechanical tensioning sensors applied to the wide Gas Electron Multiplier (GEM)
foils of the GE1/1 chambers of the Compact Muon Solenoid (CMS) experiment at
Large Hadron Collider (LHC) of CERN. A network of FBG sensors has been used to
determine the optimal mechanical tension applied and to characterize the
mechanical stress applied to the foils. The preliminary results of the test
performed on a full size GE1/1 final prototype and possible future developments
will be discussed.Comment: Four pages, seven figures. Presented by Michele Caponero at IWASI
2015, Gallipoli (Italy
Eco-friendly gas mixtures for Resistive Plate Chambers based on Tetrafluoropropene and Helium
Due to the recent restrictions deriving from the application of the Kyoto
protocol, the main components of the gas mixtures presently used in the
Resistive Plate Chambers systems of the LHC experiments will be most probably
phased out of production in the coming years. Identifying possible replacements
with the adequate characteristics requires an intense R&D, which was recently
started, also in collaborations across the various experiments. Possible
candidates have been proposed and are thoroughly investigated. Some tests on
one of the most promising candidate - HFO-1234ze, an allotropic form of
tetrafluoropropane- have already been reported. Here an innovative approach,
based on the use of Helium, to solve the problems related to the too elevate
operating voltage of HFO-1234ze based gas mixtures, is discussed and the
relative first results are shown.Comment: 9 pages, 6 figures, 1 tabl
Prodromal frontotemporal dementia: clinical features and predictors of progression
Background: The prodromal phase of frontotemporal dementia (FTD) is still not well characterized, and conversion rates to dementia and predictors of progression at 1-year follow-up are currently unknown. // Methods: In this retrospective study, disease severity was assessed using the global CDR plus NACC FTLD. Prodromal FTD was defined to reflect mild cognitive or behavioural impairment with relatively preserved functional independence (global CDR plus NACC = 0.5) as well as mild, moderate and severe dementia (classified as global CDR plus NACC = 1, 2, 3, respectively). Disease progression at 1-year follow-up and serum NfL measurements were acquired in a subgroup of patients. // Results: Of 563 participants, 138 were classified as prodromal FTD, 130 as mild, 175 as moderate and 120 as severe FTD. In the prodromal and mild phases, we observed an early increase in serum NfL levels followed by behavioural disturbances and deficits in executive functions. Negative symptoms, such as apathy, inflexibility and loss of insight, predominated in the prodromal phase. Serum NfL levels were significantly increased in the prodromal phase compared with healthy controls (average difference 14.5, 95% CI 2.9 to 26.1 pg/mL), but lower than in patients with mild FTD (average difference -15.5, 95% CI -28.4 to -2.7 pg/mL). At 1-year follow-up, 51.2% of patients in the prodromal phase had converted to dementia. Serum NfL measurements at baseline were the strongest predictors of disease progression at 1-year follow-up (OR 1.07, 95% CI 1.03 to 1.11, p < 0.001). // Conclusions: Prodromal FTD is a mutable stage with high rate of progression to fully symptomatic disease at 1-year follow-up. High serum NfL levels may support prodromal FTD diagnosis and represent a helpful marker to assess disease progression
Cms gem detector material study for the hl-lhc
A study on the Gaseous Electron Multiplier (GEM) foil material is performed to determine the moisture diffusion rate, moisture saturation level and the effects on its mechanical properties. The study is focused on the foil contact with ambient air and moisture to determine the value of the diffusion coefficient of water in the foil material. The presence of water inside the detector foil can determine the changes in its mechanical and electrical properties. A simulated model is developed with COMSOL Multiphysics v. 4.3 [1] by taking into account the real GEM foil (hole dimensions, shapes and material), which describes the adsorption of water. This work describes the model, its experimental verification, the water diffusion within the entire sheet geometry of the GEM foil, thus gaining concentration profiles and the time required to saturate the system and the effects on the mechanical properties
Properties of potential eco-friendly gas replacements for particle detectors in high-energy physics
Gas detectors for elementary particles require F-based gases for optimal performance.
Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or
banned. This work studies properties of potential eco-friendly gas replacements by computing the
physical and chemical parameters relevant for use as detector media, and suggests candidates to be
considered for experimental investigation
Properties of potential eco-friendly gas replacements for particle detectors in high-energy physics
Modern gas detectors for detection of particles require F-based gases for
optimal performance. Recent regulations demand the use of environmentally
unfriendly F-based gases to be limited or banned. This review studies
properties of potential eco-friendly gas candidate replacements.Comment: 38 pages, 9 figures, 8 tables. To be submitted to Journal of
Instrumentatio
Candidate eco-friendly gas mixtures for MPGDs
Modern gas detectors for detection of particles require F-based gases for optimal performance.Recent regulations demand the use of environmentally unfriendly F-based gases t o be limited or banned. This review studies properties of potential eco-friendly gas candidate replacements
A study of gas contaminants and interaction with materials in RPC closed loop systems
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC)
experiments use gas recirculation systems to cope with large gas mixture
volumes and costs. In this paper a long-term systematic study about gas
purifiers, gas contaminants and detector performance is discussed. The study
aims at measuring the lifetime of purifiers with unused and used cartridge
material along with contaminants release in the gas system. During the
data-taking the response of several RPC double-gap detectors was monitored in
order to characterize the correlation between dark currents, filter status and
gas contaminants
- âŠ