285 research outputs found
Advanced data extraction infrastructure: Web based system for management of time series data
During operation of high energy physics experiments a big amount of slow control data is recorded. It is necessary to examine all collected data checking the integrity and validity of measurements. With growing maturity of AJAX technologies it becomes possible to construct sophisticated interfaces using web technologies only. Our solution for handling time series, generally slow control data, has a modular architecture: backend system for data analysis and preparation, a web service interface for data access and a fast AJAX web display. In order to provide fast interactive access the time series are aggregated over time slices of few predefined lengths. The aggregated values are stored in the temporary caching database and, then, are used to create generalizing data plots. These plots may include indication of data quality and are generated within few hundreds of milliseconds even if very high data rates are involved. The extensible export subsystem provides data in multiple formats including CSV, Excel, ROOT, and TDMS. The search engine can be used to find periods of time where indications of selected sensors are falling into the specified ranges. Utilization of the caching database allows performing most of such lookups within a second. Based on this functionality a web interface facilitating fast (Google-maps style) navigation through the data has been implemented. The solution is at the moment used by several slow control systems at Test Facility for Fusion Magnets (TOSKA) and Karlsruhe Tritium Neutrino (KATRIN)
Technical design and commissioning of the KATRIN large-volume air coil system
The KATRIN experiment is a next-generation direct neutrino mass experiment
with a sensitivity of 0.2 eV (90% C.L.) to the effective mass of the electron
neutrino. It measures the tritium -decay spectrum close to its endpoint
with a spectrometer based on the MAC-E filter technique. The -decay
electrons are guided by a magnetic field that operates in the mT range in the
central spectrometer volume; it is fine-tuned by a large-volume air coil system
surrounding the spectrometer vessel. The purpose of the system is to provide
optimal transmission properties for signal electrons and to achieve efficient
magnetic shielding against background. In this paper we describe the technical
design of the air coil system, including its mechanical and electrical
properties. We outline the importance of its versatile operation modes in
background investigation and suppression techniques. We compare magnetic field
measurements in the inner spectrometer volume during system commissioning with
corresponding simulations, which allows to verify the system's functionality in
fine-tuning the magnetic field configuration. This is of major importance for a
successful neutrino mass measurement at KATRIN.Comment: 32 pages, 16 figure
A pulsed, mono-energetic and angular-selective UV photo-electron source for the commissioning of the KATRIN experiment
The KATRIN experiment aims to determine the neutrino mass scale with a
sensitivity of 200 meV/c^2 (90% C.L.) by a precision measurement of the shape
of the tritium -spectrum in the endpoint region. The energy analysis of
the decay electrons is achieved by a MAC-E filter spectrometer. To determine
the transmission properties of the KATRIN main spectrometer, a mono-energetic
and angular-selective electron source has been developed. In preparation for
the second commissioning phase of the main spectrometer, a measurement phase
was carried out at the KATRIN monitor spectrometer where the device was
operated in a MAC-E filter setup for testing. The results of these measurements
are compared with simulations using the particle-tracking software
"Kassiopeia", which was developed in the KATRIN collaboration over recent
years.Comment: 19 pages, 16 figures, submitted to European Physical Journal
Forward Beam Monitor for the KATRIN experiment
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to measure the neutrino mass with a sensitivity of 0.2 eV (90 % CL). This will be achieved by a precision measurement of the endpoint region of the β-electron spectrum of tritium decay. The β-electrons are produced in the Windowless Gaseous Tritium Source (WGTS) and guided magnetically through the beamline. In order to accurately extract the neutrino mass the source activity is required to be stable and known to a high precision. The WGTS therefore undergoes constant extensive monitoring from several measurement systems. The Forward Beam Monitor (FBM) is one such monitoring system. The FBM system comprises a complex mechanical setup capable of inserting a detector board into the KATRIN beamline with a positioning precision of better than 0.3 mm. The electron flux density at that position is on the order of 10 s mm. The detector board contains two silicon detector chips of p-i-n diode type which can measure the β-electron flux from the source with a precision of 0.1 % within 60 s with an energy resolution of FWHM = 2 keV. The unique challenge in developing the FBM arises from its designated operating environment inside the Cryogenic Pumping Section which is a potentially tritium contaminated ultra-high vacuum chamber at cryogenic temperatures in the presence of a 1 T strong magnetic field. Each of these parameters do strongly limit the choice of possible materials which e.g. caused difficulties in detector noise reduction, heat dissipation and lubrication. In order to completely remove the FBM from the beam tube a 2 m long traveling distance into the beamline is needed demanding a robust as well as highly precise moving mechanism
Focal-plane detector system for the KATRIN experiment
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation
- …