249 research outputs found

    Upturn observed in heavy nuclei to iron ratios by the ATIC-2 experiment

    Get PDF
    The ratios of fluxes of heavy nuclei from sulfur (Z=16) to chromium (Z=24) to the flux of iron were measured by the ATIC-2 experiment. The ratios are decreasing functions of energy from 5 GeV/n to approximately 80 GeV/n, as expected. However, an unexpected sharp upturn in the ratios are observed for energies above 100 GeV/n for all elements from Z=16 to Z=24. Similar upturn but with lower amplitude was also discovered in the ATIC-2 data for the ratio of fluxes of abundant even nuclei (C, O, Ne, Mg, Si) to the flux of iron. Therefore the spectrum of iron is significantly different from the spectra of other abundant even nuclei.Comment: 4 pages, LaTeX2e, a paper for 23rd European Cosmic Ray Symposium (2012

    Latin adjectives with the meaning of similarity in medical terminology

    Get PDF
    The article describes Latin adjectives with the meaning of similarity in medical terminology. As a result of the analysis, characteristic features are revealed, according to which it is possible to differentiate and classify these words, their β€œbehavior” in terms is studied. In addition, the article provides a comparative analysis of the terms of anatomical and clinical terminology, as well as a contrastive analysis of Russian Federationn and Latin adjectivesΠ’ ΡΡ‚Π°Ρ‚ΡŒΠ΅ ΠΎΠΏΠΈΡΡ‹Π²Π°ΡŽΡ‚ΡΡ латинскиС ΠΏΡ€ΠΈΠ»Π°Π³Π°Ρ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ со Π·Π½Π°Ρ‡Π΅Π½ΠΈΠ΅ΠΌ подобия Π² мСдицинской Ρ‚Π΅Ρ€ΠΌΠΈΠ½ΠΎΠ»ΠΎΠ³ΠΈΠΈ. Π’ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Π΅ Π°Π½Π°Π»ΠΈΠ·Π° Π²Ρ‹ΡΠ²Π»ΡΡŽΡ‚ΡΡ Ρ…Π°Ρ€Π°ΠΊΡ‚Π΅Ρ€Π½Ρ‹Π΅ ΠΏΡ€ΠΈΠ·Π½Π°ΠΊΠΈ, ΠΏΠΎ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹ΠΌ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½Π° диффСрСнциация ΠΈ классификация Π΄Π°Π½Π½Ρ‹Ρ… слов, ΠΈΡ… Β«ΠΏΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠ΅Β» Π² Ρ‚Π΅Ρ€ΠΌΠΈΠ½Π°Ρ…. ΠšΡ€ΠΎΠΌΠ΅ Ρ‚ΠΎΠ³ΠΎ, Π² ΡΡ‚Π°Ρ‚ΡŒΠ΅ проводится ΡΡ€Π°Π²Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ Π°Π½Π°Π»ΠΈΠ· Ρ‚Π΅Ρ€ΠΌΠΈΠ½ΠΎΠ² анатомичСской ΠΈ клиничСской Ρ‚Π΅Ρ€ΠΌΠΈΠ½ΠΎΠ»ΠΎΠ³ΠΈΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ контрастивный Π°Π½Π°Π»ΠΈΠ· русских ΠΈ латинских ΠΏΡ€ΠΈΠ»Π°Π³Π°Ρ‚Π΅Π»ΡŒΠ½Ρ‹Ρ…

    Relative abundances of cosmic ray nuclei B-C-N-O in the energy region from 10 GeV/n to 300 GeV/n. Results from ATIC-2 (the science flight of ATIC)

    Full text link
    The ATIC balloon-borne experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germanate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as the main charge detector. The silicon matrix produces good charge resolution for protons and helium but only partial resolution for heavier nuclei. In the present paper, the charge resolution of ATIC was improved and backgrounds were reduced in the region from Be to Si by using the upper layer of the scintillator hodoscope as an additional charge detector. The flux ratios of nuclei B/C, C/O, N/O in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon obtained from this high-resolution, high-quality charge spectra are presented, and compared with existing theoretical predictions.Comment: 4 pages,2 figures, a paper for 30-th International Cosmic Rays Conferenc

    Possible structure in the cosmic ray electron spectrum measured by the ATIC-2 and ATIC-4 experiments

    Get PDF
    A strong excess in a form of a wide peak in the energy range of 300-800 GeV was discovered in the first measurements of the electron spectrum in the energy range from 20 GeV to 3 TeV by the balloon-borne experiment ATIC (J. Chang et al. Nature, 2008). The experimental data processing and analysis of the electron spectrum with different criteria for selection of electrons, completely independent of the results reported in (J. Chang et al. Nature, 2008) is employed in the present paper. The new independent analysis generally confirms the results of (J. Chang et al. Nature, 2008), but shows that the spectrum in the region of the excess is represented by a number of narrow peaks. The measured spectrum is compared to the spectrum of (J. Chang et al. Nature, 2008) and to the spectrum of the Fermi/LAT experiment.Comment: LaTeX2e, 10 pages, 4 figures, a paper for ECRS 2010 (Turku, Finland); http://www.astrophys-space-sci-trans.net/7/119/2011

    Simulation of the ATIC-2 Silicon Matrix for Protons and Helium GCR Primaries at 0.3, 10, and 25 TeV/Nucleon

    Get PDF
    The energy deposition distribution for protons and helium galactic cosmic ray primaries at 0.3, 10, and 25 TeV/nucleon in the ATIC-2 silicon matrix detector are simulated with GEANT4. The GEANT3 geometrical model of ATIC developed by the University of Maryland was combined with a GEANT4 application developed for the Deep Space Test Bed (DSTB) detector package. The new code included relatively minor modifications to completely describe the ATIC materials and a more detailed model of the Silicon Matrix detector. For this analysis all particles were started as a unidirectional beam at a single point near the center of the Silicon Matrix front surface. The point was selected such that each primary passed through at least two of the overlapping silicon pixels

    A Detailed FLUKA-2005 Monte Carlo Simulation for the ATIC Detector

    Get PDF
    We have performed a detailed Monte Carlo (MC) calculation for the Advanced thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2005 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon Bight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy; using a fully active Bismuth Germanate @GO) calorimeter. It is equipped with a large mosaic of silicon detector pixels capable of charge identification and as a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target. Our calculations are part of an analysis package of both A- and energy-dependences of different nuclei interacting with the ATIC detector. The MC simulates the responses of different components of the detector such as the Simatrix, the scintillator hodoscopes and the BGO calorimeter to various nuclei. We also show comparisons of the FLUKA-2005 MC calculations with a GEANT calculation and data for protons, He and CNO

    Energy dependence of Ti/Fe ratio in the Galactic cosmic rays measured by the ATIC-2 experiment

    Get PDF
    Titanium is a rare, secondary nucleus among Galactic cosmic rays. Using the Silicon matrix in the ATIC experiment, Titanium has been separated. The energy dependence of the Ti to Fe flux ratio in the energy region from 5 GeV per nucleon to about 500 GeV per nucleon is presented.Comment: 8 pages, 4 figures, accepted for publication in Astronomy Letter

    Mesenchymal stem (stromal) cells in myocardial infarction treatment

    Get PDF
    The article deals with some properties of mesenchymal stem (stromal) cells (MSC) and with possibility of application of MSC in cellular therapy of myocardial infarction.Π’ ΡΡ‚Π°Ρ‚ΡŒΠ΅ рассмотрСны Π½Π΅ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ свойства ΠΌΠ΅Π·Π΅Π½Π·ΠΈΠΌΠ°Π»ΡŒΠ½Ρ‹Ρ… стволовых (ΡΡ‚Ρ€ΠΎΠΌΠ°Π»ΡŒΠ½Ρ‹Ρ…) ΠΊΠ»Π΅Ρ‚ΠΎΠΊ (МБК), Π° Ρ‚Π°ΠΊΠΆΠ΅ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ ΠΈΡ… примСнСния Π² ΠΊΠ»Π΅Ρ‚ΠΎΡ‡Π½ΠΎΠΉ Ρ‚Π΅Ρ€Π°ΠΏΠΈΠΈ ΠΈΠ½Ρ„Π°Ρ€ΠΊΡ‚Π° ΠΌΠΈΠΎΠΊΠ°Ρ€Π΄

    Electrocardiographic parameters and magnesium level relations in laboratory rabbits treated with levofloxacin

    Get PDF
    The purpose of the study is to investigate interrelations between electrocardiographic parameters and serum magnesium levels in laboratory rabbits treated with levofloxacin.ЦСль исслСдования – ΠΈΠ·ΡƒΡ‡ΠΈΡ‚ΡŒ взаимосвязь элСктрокардиографичСских ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠ² ΠΈ сывороточного уровня магния Ρƒ Π»Π°Π±ΠΎΡ€Π°Ρ‚ΠΎΡ€Π½Ρ‹Ρ… ΠΊΡ€ΠΎΠ»ΠΈΠΊΠΎΠ², ΠΏΠΎΠ»ΡƒΡ‡Π°ΡŽΡ‰ΠΈΡ… лСвофлоксацин
    • …
    corecore