249 research outputs found
Upturn observed in heavy nuclei to iron ratios by the ATIC-2 experiment
The ratios of fluxes of heavy nuclei from sulfur (Z=16) to chromium (Z=24) to
the flux of iron were measured by the ATIC-2 experiment. The ratios are
decreasing functions of energy from 5 GeV/n to approximately 80 GeV/n, as
expected. However, an unexpected sharp upturn in the ratios are observed for
energies above 100 GeV/n for all elements from Z=16 to Z=24. Similar upturn but
with lower amplitude was also discovered in the ATIC-2 data for the ratio of
fluxes of abundant even nuclei (C, O, Ne, Mg, Si) to the flux of iron.
Therefore the spectrum of iron is significantly different from the spectra of
other abundant even nuclei.Comment: 4 pages, LaTeX2e, a paper for 23rd European Cosmic Ray Symposium
(2012
Latin adjectives with the meaning of similarity in medical terminology
The article describes Latin adjectives with the meaning of similarity in medical terminology. As a result of the analysis, characteristic features are revealed, according to which it is possible to differentiate and classify these words, their βbehaviorβ in terms is studied. In addition, the article provides a comparative analysis of the terms of anatomical and clinical terminology, as well as a contrastive analysis of Russian Federationn and Latin adjectivesΠ ΡΡΠ°ΡΡΠ΅ ΠΎΠΏΠΈΡΡΠ²Π°ΡΡΡΡ Π»Π°ΡΠΈΠ½ΡΠΊΠΈΠ΅ ΠΏΡΠΈΠ»Π°Π³Π°ΡΠ΅Π»ΡΠ½ΡΠ΅ ΡΠΎ Π·Π½Π°ΡΠ΅Π½ΠΈΠ΅ΠΌ ΠΏΠΎΠ΄ΠΎΠ±ΠΈΡ Π² ΠΌΠ΅Π΄ΠΈΡΠΈΠ½ΡΠΊΠΎΠΉ ΡΠ΅ΡΠΌΠΈΠ½ΠΎΠ»ΠΎΠ³ΠΈΠΈ. Π ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠ΅ Π°Π½Π°Π»ΠΈΠ·Π° Π²ΡΡΠ²Π»ΡΡΡΡΡ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠ½ΡΠ΅ ΠΏΡΠΈΠ·Π½Π°ΠΊΠΈ, ΠΏΠΎ ΠΊΠΎΡΠΎΡΡΠΌ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½Π° Π΄ΠΈΡΡΠ΅ΡΠ΅Π½ΡΠΈΠ°ΡΠΈΡ ΠΈ ΠΊΠ»Π°ΡΡΠΈΡΠΈΠΊΠ°ΡΠΈΡ Π΄Π°Π½Π½ΡΡ
ΡΠ»ΠΎΠ², ΠΈΡ
Β«ΠΏΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠ΅Β» Π² ΡΠ΅ΡΠΌΠΈΠ½Π°Ρ
. ΠΡΠΎΠΌΠ΅ ΡΠΎΠ³ΠΎ, Π² ΡΡΠ°ΡΡΠ΅ ΠΏΡΠΎΠ²ΠΎΠ΄ΠΈΡΡΡ ΡΡΠ°Π²Π½ΠΈΡΠ΅Π»ΡΠ½ΡΠΉ Π°Π½Π°Π»ΠΈΠ· ΡΠ΅ΡΠΌΠΈΠ½ΠΎΠ² Π°Π½Π°ΡΠΎΠΌΠΈΡΠ΅ΡΠΊΠΎΠΉ ΠΈ ΠΊΠ»ΠΈΠ½ΠΈΡΠ΅ΡΠΊΠΎΠΉ ΡΠ΅ΡΠΌΠΈΠ½ΠΎΠ»ΠΎΠ³ΠΈΠΈ, Π° ΡΠ°ΠΊΠΆΠ΅ ΠΊΠΎΠ½ΡΡΠ°ΡΡΠΈΠ²Π½ΡΠΉ Π°Π½Π°Π»ΠΈΠ· ΡΡΡΡΠΊΠΈΡ
ΠΈ Π»Π°ΡΠΈΠ½ΡΠΊΠΈΡ
ΠΏΡΠΈΠ»Π°Π³Π°ΡΠ΅Π»ΡΠ½ΡΡ
Relative abundances of cosmic ray nuclei B-C-N-O in the energy region from 10 GeV/n to 300 GeV/n. Results from ATIC-2 (the science flight of ATIC)
The ATIC balloon-borne experiment measures the energy spectra of elements
from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is
comprised of a fully active bismuth germanate calorimeter, a carbon target with
embedded scintillator hodoscopes, and a silicon matrix that is used as the main
charge detector. The silicon matrix produces good charge resolution for protons
and helium but only partial resolution for heavier nuclei. In the present
paper, the charge resolution of ATIC was improved and backgrounds were reduced
in the region from Be to Si by using the upper layer of the scintillator
hodoscope as an additional charge detector. The flux ratios of nuclei B/C, C/O,
N/O in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon obtained
from this high-resolution, high-quality charge spectra are presented, and
compared with existing theoretical predictions.Comment: 4 pages,2 figures, a paper for 30-th International Cosmic Rays
Conferenc
Possible structure in the cosmic ray electron spectrum measured by the ATIC-2 and ATIC-4 experiments
A strong excess in a form of a wide peak in the energy range of 300-800 GeV
was discovered in the first measurements of the electron spectrum in the energy
range from 20 GeV to 3 TeV by the balloon-borne experiment ATIC (J. Chang et
al. Nature, 2008). The experimental data processing and analysis of the
electron spectrum with different criteria for selection of electrons,
completely independent of the results reported in (J. Chang et al. Nature,
2008) is employed in the present paper. The new independent analysis generally
confirms the results of (J. Chang et al. Nature, 2008), but shows that the
spectrum in the region of the excess is represented by a number of narrow
peaks. The measured spectrum is compared to the spectrum of (J. Chang et al.
Nature, 2008) and to the spectrum of the Fermi/LAT experiment.Comment: LaTeX2e, 10 pages, 4 figures, a paper for ECRS 2010 (Turku, Finland);
http://www.astrophys-space-sci-trans.net/7/119/2011
Simulation of the ATIC-2 Silicon Matrix for Protons and Helium GCR Primaries at 0.3, 10, and 25 TeV/Nucleon
The energy deposition distribution for protons and helium galactic cosmic ray primaries at 0.3, 10, and 25 TeV/nucleon in the ATIC-2 silicon matrix detector are simulated with GEANT4. The GEANT3 geometrical model of ATIC developed by the University of Maryland was combined with a GEANT4 application developed for the Deep Space Test Bed (DSTB) detector package. The new code included relatively minor modifications to completely describe the ATIC materials and a more detailed model of the Silicon Matrix detector. For this analysis all particles were started as a unidirectional beam at a single point near the center of the Silicon Matrix front surface. The point was selected such that each primary passed through at least two of the overlapping silicon pixels
A Detailed FLUKA-2005 Monte Carlo Simulation for the ATIC Detector
We have performed a detailed Monte Carlo (MC) calculation for the Advanced thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2005 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon Bight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy; using a fully active Bismuth Germanate @GO) calorimeter. It is equipped with a large mosaic of silicon detector pixels capable of charge identification and as a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target. Our calculations are part of an analysis package of both A- and energy-dependences of different nuclei interacting with the ATIC detector. The MC simulates the responses of different components of the detector such as the Simatrix, the scintillator hodoscopes and the BGO calorimeter to various nuclei. We also show comparisons of the FLUKA-2005 MC calculations with a GEANT calculation and data for protons, He and CNO
Energy dependence of Ti/Fe ratio in the Galactic cosmic rays measured by the ATIC-2 experiment
Titanium is a rare, secondary nucleus among Galactic cosmic rays. Using the
Silicon matrix in the ATIC experiment, Titanium has been separated. The energy
dependence of the Ti to Fe flux ratio in the energy region from 5 GeV per
nucleon to about 500 GeV per nucleon is presented.Comment: 8 pages, 4 figures, accepted for publication in Astronomy Letter
Mesenchymal stem (stromal) cells in myocardial infarction treatment
The article deals with some properties of mesenchymal stem (stromal) cells (MSC) and with possibility of application of MSC in cellular therapy of myocardial infarction.Π ΡΡΠ°ΡΡΠ΅ ΡΠ°ΡΡΠΌΠΎΡΡΠ΅Π½Ρ Π½Π΅ΠΊΠΎΡΠΎΡΡΠ΅ ΡΠ²ΠΎΠΉΡΡΠ²Π° ΠΌΠ΅Π·Π΅Π½Π·ΠΈΠΌΠ°Π»ΡΠ½ΡΡ
ΡΡΠ²ΠΎΠ»ΠΎΠ²ΡΡ
(ΡΡΡΠΎΠΌΠ°Π»ΡΠ½ΡΡ
) ΠΊΠ»Π΅ΡΠΎΠΊ (ΠΠ‘Π), Π° ΡΠ°ΠΊΠΆΠ΅ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡΡ ΠΈΡ
ΠΏΡΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡ Π² ΠΊΠ»Π΅ΡΠΎΡΠ½ΠΎΠΉ ΡΠ΅ΡΠ°ΠΏΠΈΠΈ ΠΈΠ½ΡΠ°ΡΠΊΡΠ° ΠΌΠΈΠΎΠΊΠ°ΡΠ΄
Electrocardiographic parameters and magnesium level relations in laboratory rabbits treated with levofloxacin
The purpose of the study is to investigate interrelations between electrocardiographic parameters and serum magnesium levels in laboratory rabbits treated with levofloxacin.Π¦Π΅Π»Ρ ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΡ β ΠΈΠ·ΡΡΠΈΡΡ Π²Π·Π°ΠΈΠΌΠΎΡΠ²ΡΠ·Ρ ΡΠ»Π΅ΠΊΡΡΠΎΠΊΠ°ΡΠ΄ΠΈΠΎΠ³ΡΠ°ΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΏΠ°ΡΠ°ΠΌΠ΅ΡΡΠΎΠ² ΠΈ ΡΡΠ²ΠΎΡΠΎΡΠΎΡΠ½ΠΎΠ³ΠΎ ΡΡΠΎΠ²Π½Ρ ΠΌΠ°Π³Π½ΠΈΡ Ρ Π»Π°Π±ΠΎΡΠ°ΡΠΎΡΠ½ΡΡ
ΠΊΡΠΎΠ»ΠΈΠΊΠΎΠ², ΠΏΠΎΠ»ΡΡΠ°ΡΡΠΈΡ
Π»Π΅Π²ΠΎΡΠ»ΠΎΠΊΡΠ°ΡΠΈΠ½
- β¦