    SENSE and simultaneous multislice imaging

    Get PDF
    PurposeSimultaneous multislice (SMS) acquisitions play an important role in the challenge of increasing single-shot imaging speed. We show that sensitivity encoding in two spatial dimensions (two-dimensional sensitivity encoding [2D-SENSE]) can be used to reconstruct SMS acquisitions with periodic but otherwise arbitrary undersampling patterns. Theory and MethodsBy adopting a 3D k-space representation of the SMS sampling process, the accelerated in-plane and slice-encoding directions form a 2D-reconstruction problem that is equivalent to volumetric controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). 2D-SENSE does not otherwise distinguish between standard volumetric and SMS imaging with arbitrary CAIPIRINHA sampling. ResultsUse of the SENSE algorithm is demonstrated for in vivo brain data obtained with blipped-CAIPRINHA sampling in 2D SMS-echo planar imaging (EPI) and rapid acquisition with relaxation enhancement (RARE) acquisitions as well as 3D-EPI with various in-plane and through-plane acceleration factors and CAIPIRINHA shifts. The proposed SENSE reconstruction works for any combination of SMS-factor and CAIPIRINHA shift by the addition of dummy slices that allow for noninteger undersampling in the slice direction. Images with commonly used slice-generalized autocalibrating partially parallel acquisitions reconstruction are shown for reference. ConclusionSENSE is conceptually simple and provides a one-step reconstruction along both undersampled dimensions. It also provides a contrast-independent parallel imaging reconstruction for SMS. Magn Reson Med 74:1356-1362, 2015. (c) 2014 Wiley Periodicals, Inc

    Sensitivity to local dipole fields in the CRAZED Experiment: An approach to bright spot MRI

    No full text
    Local dipole fields such as those created by small iron-oxide particles are used to produce regions of low intensity (dark contrast) in many molecular magnetic resonance imaging applications. We have investigated, with computer simulations and experiments at 17.6 T, how the COSY revamped with asymmetric z-gradient echo detection (CRAZED) experiment that selects intermolecular double-quantum coherences can also be used to visualize such local dipole fields. Application of the coherence-selection gradient pulses parallel to the main magnetic field produced similar, dark contrast as conventional gradient echo imaging. Application of the gradient along the magic angle leads to total loss of signal intensity in homogeneous samples. In the presence of local dipole fields, the contrast was inverted and bright signals from the dipoles were observed over a very low background. Both simulations and experiments showed that the signal strongly decreased when a phase-cycle suppressing single-quantum coherences was employed. Therefore, we conclude that most of the signal comes from directly refocused magnetization or intermolecular single-quantum coherences. Finally, we demonstrate that bright contrast from local dipole fields can also be obtained, when the pair of coherence-selection gradient pulses is deliberately mismatched. Both methods allowed visualization of local dipole fields in phantoms in experimental times of about 3 min

    MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T.

    No full text
    PurposeTo develop a 7T simultaneous multi-slice (SMS) 2D gradient-echo sequence for susceptibility contrast imaging, and to compare its quality to 3D imaging.MethodsA frequency modulated and phase cycled RF pulse was designed to simultaneously excite multiple slices in multi-echo 2D gradient-echo imaging. The imaging parameters were chosen to generate images with susceptibility contrast, including T2*-weighted magnitude/phase images, susceptibility-weighted images and quantitative susceptibility/R2* maps. To compare their image quality with 3D gradient-echo imaging, both 2D and 3D imaging were performed on 11 healthy volunteers and 4 patients with multiple sclerosis (MS). The signal to noise ratio (SNR) in gray and white matter and their contrast to noise ratio (CNR) was simulated for the 2D and 3D magnitude images using parameters from the imaging. The experimental SNRs and CNRs were measured in gray/white matter and deep gray matter structures on magnitude, phase, R2* and QSM images from volunteers and the visibility of MS lesions on these images from patients was visually rated. All SNRs and CNRs were compared between the 2D and 3D imaging using a paired t-test.ResultsAlthough the 3D magnitude images still had significantly higher SNRs (by 13.0~17.6%), the 2D magnitude and QSM images generated significantly higher gray/white matter or globus pallidus/putamen contrast (by 13.3~87.5%) and significantly higher MS lesion contrast (by 5.9~17.3%).Conclusion2D SMS gradient-echo imaging can serve as an alternative to often used 3D imaging to obtain susceptibility-contrast-weighted images, with an advantage of providing better image contrast and MS lesion sensitivity

    Spectral analysis of physiological brain pulsations affecting the BOLD signal

    No full text
    Abstract Physiological pulsations have been shown to affect the global blood oxygen level dependent (BOLD) signal in human brain. While these pulsations have previously been regarded as noise, recent studies show their potential as biomarkers of brain pathology. We used the extended 5 Hz spectral range of magnetic resonance encephalography (MREG) data to investigate spatial and frequency distributions of physiological BOLD signal sources. Amplitude spectra of the global image signals revealed cardiorespiratory envelope modulation (CREM) peaks, in addition to the previously known very low frequency (VLF) and cardiorespiratory pulsations. We then proceeded to extend the amplitude of low frequency fluctuations (ALFF) method to each of these pulsations. The respiratory pulsations were spatially dominating over most brain structures. The VLF pulsations overcame the respiratory pulsations in frontal and parietal gray matter, whereas cardiac and CREM pulsations had this effect in central cerebrospinal fluid (CSF) spaces and major blood vessels. A quasi-periodic pattern (QPP) analysis showed that the CREM pulsations propagated as waves, with a spatiotemporal pattern differing from that of respiratory pulsations, indicating them to be distinct intracranial physiological phenomenon. In conclusion, the respiration has a dominant effect on the global BOLD signal and directly modulates cardiovascular brain pulsations