40 research outputs found

    Infrapatellar Straps Decrease Patellar Tendon Strain at the Site of the Jumper’s Knee Lesion

    Full text link
    Background: The impetus for the use of patellar straps in the treatment of patellar tendinopathy has largely been based on empirical evidence and not on any mechanistic rationale. A computational model suggests that patellar tendinopathy may be a result of high localized tendon strains that occur at smaller patella–patellar tendon angles (PPTAs). Hypothesis: Infrapatellar straps will decrease the mean localized computational strain in the area of the patellar tendon commonly involved in jumper’s knee by increasing the PPTA. Study Design: Controlled laboratory study. Methods: Twenty adult males had lateral weightbearing and nonweightbearing radiographs of their knees taken with and without 1 of 2 infrapatellar straps at 60° of knee flexion. Morphologic measurements of PPTA and patellar tendon length with and without the straps were used as input data into a previously described computational model to calculate average and maximum strain at the common location of the jumper’s knee lesion during a simulated jump landing. Results: The infrapatellar bands decreased the predicted localized strain (average and maximum) in the majority of participants by increasing PPTA and/or decreasing patellar tendon length. When both PPTA and patellar tendon length were altered by the straps, there was a strong and significant correlation with the change in predicted average localized strain with both straps. Conclusion: Infrapatellar straps may limit excessive patella tendon strain at the site of the jumper’s knee lesion by increasing PPTA and decreasing patellar tendon length rather than by correcting some inherent anatomic or functional abnormality in the extensor apparatus. Clinical Relevance: The use of infrapatellar straps may help prevent excessive localized tendon strains at the site of the jumper’s knee lesion during a jump landing

    Tendon mechanobiology: Current knowledge and future research opportunities: TENDON MECHANOBIOLOGY

    Get PDF
    Tendons mainly function as load-bearing tissues in the muscloskeletal system, transmitting loads from muscle to bone. Tendons are dynamic structures that respond to the magnitude, direction, frequency, and duration of physiologic as well as pathologic mechanical loads via complex interactions between cellular pathways and the highly specialized extracellular matrix. This paper reviews the evolution and current knowledge of mechanobiology in tendon development, homeostasis, disease, and repair. In addition, we review several novel mechanotransduction pathways that have been identified recently in other tissues and cell types, providing potential research opportunities in the field of tendon mechanobiology. We also highlight current methods, models, and technologies being used in a wide variety of mechanobiology research that could be investigated in the context of their potential applicability for answering some of the fundamental unanswered questions in this field. The article concludes with a review of the major questions and future goals discussed during the recent ORS/ISMMS New Frontiers in Tendon Research Conference held September 10–11, 2014 in New York City

    Biomanufacturing Organized Collagen-Based Microfibers as a Tissue ENgineered Device (TEND) for Tendon Regeneration

    Get PDF
    Approximately 800,000 surgical repairs are performed annually in the U.S. for debilitating injuries to ligaments and tendons of the foot, ankle, knee, wrist, elbow and shoulder, presenting a significant healthcare burden. To overcome current treatment shortcomings and advance the treatment of tendon and ligament injuries, we have developed a novel electrospun Tissue ENgineered Device (TEND), comprised of type I collagen and poly(D,L-lactide) (PDLLA) solubilized in a benign solvent, dimethyl sulfoxide (DMSO). TEND fiber alignment, diameter and porosity were engineered to enhance cell infiltration leading to promote tissue integration and functional remodeling while providing biomechanical stability. TEND rapidly adsorbs blood and platelet-rich-plasma (PRP), gradually releases growth factors over two weeks. TEND further supported cellular alignment and upregulation of tenogenic genes from clinically relevant human stem cells within three days of culture. TEND implanted in a rabbit Achilles tendon injury model showed new in situ tissue generation, maturation, and remodeling of dense, regularly oriented connective tissue in vivo. In all, TEND\u27s organized microfibers, biological fluid and cell compatibility, strength and biocompatiblility make significant progress towards clinically translating electrospun collagen-based medical devices for improving the clinical outcomes of tendon injuries

    Microvasculature of the human meniscus

    No full text

    Tendon cell ciliary length as a biomarker of in situ cytoskeletal tensional homeostasis

    Get PDF
    To determine if tendon cell ciliary length could be used as a biomarker of cytoskeletal tensional homeostasis, 20 mm long adult rat tail tendons were placed in double artery clamps set 18 mm apart to create a 10% laxity. The tendons were allowed to contract over a 7 day period under culture conditions. At 0, 1, 5, and 7 days the tendon cell cilia were stained and ciliary length measured using confocal imaging. There was a significant (p<0.001) increase in ciliary length at 1 day. At day 5 (when the tendon became visibly taut) there was a significant (p<0.001) decrease in ciliary length compared to day 1. By day 7 the tendon remained taut and ciliary length returned to day zero values (p=0.883). These results suggest that cilia length reflects the local mechanobiological environment of tendon cells and could be used as a potential in situ biomarker of altered cytoskeletal tensional homeostasi
    corecore