13 research outputs found

    One Year Assessment of the Hearing Preservation Potential of the EVO Electrode Array.

    No full text
    International audienceBackground: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. Methods: Fifteen adults presenting indications of electro-acoustic stimulation (pure-tone audiometry (PTA) thresholds ≤70 dB below 750 Hz) were implanted with the EVO™ electrode array. Hearing thresholds were collected at five time-points from CI activation to twelve months (12M) after activation. Hearing thresholds and hearing preservation profiles (HEARRING group classification) were assessed. Results: All subjects had measurable hearing thresholds at follow-up. No case of complete loss of hearing or minimal hearing preservation was reported at any time point. At activation (Nact = 15), five participants had complete hearing preservation, and ten participants had partial hearing preservation. At the 12M time point (N12m = 6), three participants had complete hearing preservation, and three participants had partial hearing preservation. Mean hearing loss at activation was 11 dB for full range PTA and 25 dB for PTAs low-frequency (125–500 Hz). Conclusions: This study provides the first longitudinal follow-up on associated hearing profiles to the EVO™ electrode array, which are comparable to the literature. However, other studies on larger populations should be performed

    The Development of the “Telislife” Questionnaire for the Evaluation of Telephone Use in Cochlear Implant Users

    No full text
    Purpose For cochlear implant users, the ability to use the telephone is often seen as an important landmark during rehabilitation and an indicator of cochlear implant benefit. The goal of this study was to develop a short questionnaire exploring the ability to use the telephone in cochlear implant users, named Telislife, and test it in a group of experienced users. Method This prospective multicenter study was based on the completion of self-administrated questionnaires. The Telislife includes 20 items using a 5-point Likert scale for answers. Speech recognition scores were obtained with monosyllabic word lists at 70 dB HL. Quality of life was evaluated with the Nijmegen Cochlear Implant Questionnaire. This study included 55 adult patients wearing a cochlear implant for over 1 year. Results The Telislife questionnaire showed excellent reliability (Cronbach's α = .91). A significant correlation was found between Telislife scores and Nijmegen Cochlear Implant Questionnaire scores (r = .69, p < .001) and speech recognition scores (r = .35, p = .007). Conclusion Given significant correlations between Telislife scores and both speech recognition and quality of life and given its short form, the Telislife questionnaire appears to be a reliable tool to evaluate cochlear implant outcomes in clinical practice

    Adult Users of the Oticon Medical Neuro Cochlear Implant System Benefit from Beamforming in the High Frequencies

    No full text
    The Oticon Medical Neuro cochlear implant system includes the modes Opti Omni and Speech Omni, the latter providing beamforming (i.e., directional selectivity) in the high frequencies. Two studies compared sentence identification scores of adult cochlear implant users with Opti Omni and Speech Omni. In Study 1, a double-blind longitudinal crossover study, 12 new users trialed Opti Omni or Speech Omni (random allocation) for three months, and their sentence identification in quiet and noise (+10 dB signal-to-noise ratio) with the trialed mode were measured. The same procedure was repeated for the second mode. In Study 2, a single-blind study, 11 experienced users performed a speech identification task in quiet and at relative signal-to-noise ratios ranging from -3 to +18 dB with Opti Omni and Speech Omni. The Study 1 scores in quiet and in noise were significantly better with Speech Omni than with Opti Omni. Study 2 scores were significantly better with Speech Omni than with Opti Omni at +6 and +9 dB signal-to-noise ratios. Beamforming in the high frequencies, as implemented in Speech Omni, leads to improved speech identification in medium levels of background noise, where cochlear implant users spend most of their day.Funding Agencies|Oticon Medical; Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (Coordination for the Improvement of Higher Education Personnel) from the Ministry of Education of Brazil</p

    One Year Assessment of the Hearing Preservation Potential of the EVO Electrode Array

    No full text
    Background: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. Methods: Fifteen adults presenting indications of electro-acoustic stimulation (pure-tone audiometry (PTA) thresholds &le;70 dB below 750 Hz) were implanted with the EVO&trade; electrode array. Hearing thresholds were collected at five time-points from CI activation to twelve months (12M) after activation. Hearing thresholds and hearing preservation profiles (HEARRING group classification) were assessed. Results: All subjects had measurable hearing thresholds at follow-up. No case of complete loss of hearing or minimal hearing preservation was reported at any time point. At activation (Nact = 15), five participants had complete hearing preservation, and ten participants had partial hearing preservation. At the 12M time point (N12m = 6), three participants had complete hearing preservation, and three participants had partial hearing preservation. Mean hearing loss at activation was 11 dB for full range PTA and 25 dB for PTAs low-frequency (125&ndash;500 Hz). Conclusions: This study provides the first longitudinal follow-up on associated hearing profiles to the EVO&trade; electrode array, which are comparable to the literature. However, other studies on larger populations should be performed