13 research outputs found
Col11a2 Deletion Reveals the Molecular Basis for Tectorial Membrane Mechanical Anisotropy
The tectorial membrane (TM) has a significantly larger stiffness in the radial direction than other directions, a prominent mechanical anisotropy that is believed to be critical for the proper functioning of the cochlea. To determine the molecular basis of this anisotropy, we measured material properties of TMs from mice with a targeted deletion of Col11a2, which encodes for collagen XI. In light micrographs, the density of TM radial collagen fibers was lower in Col11a2 –/– mice than wild-types. Tone-evoked distortion product otoacoustic emission and auditory brainstem response measurements in Col11a2 –/– mice were reduced by 30–50 dB independent of frequency as compared with wild-types, showing that the sensitivity loss is cochlear in origin. Stress-strain measurements made using osmotic pressure revealed no significant dependence of TM bulk compressibility on the presence of collagen XI. Charge measurements made by placing the TM as an electrical conduit between two baths revealed no change in the density of charge affixed to the TM matrix in Col11a2 –/– mice. Measurements of mechanical shear impedance revealed a 5.5 ± 0.8 dB decrease in radial shear impedance and a 3.3 ± 0.3 dB decrease in longitudinal shear impedance resulting from the Col11a2 deletion. The ratio of radial to longitudinal shear impedance fell from 1.8 ± 0.7 for TMs from wild-type mice to 1.0 ± 0.1 for those from Col11a2 –/– mice. These results show that the organization of collagen into radial fibrils is responsible for the mechanical anisotropy of the TM. This anisotropy can be attributed to increased mechanical coupling provided by the collagen fibrils. Mechanisms by which changes in TM material properties may contribute to the threshold elevation in Col11a2 –/– mice are discussed.National Institutes of Health (U.S.) (Grant R01-DC00238
Computer Microvision for Microelectromechanical Systems
Contains table of contents for Section 3 and reports on five research projects.Charles S. Draper Laboratory Contract DL-H-496015Defense Advanced Research Project Agency Grant F30602-97-2-0106W.M. Keck Foundation Career Development ProfessorshipAlfred P. Sloan Foundation Instrumentation Gran
Signal Transmission in the Auditory System
Contains table of contents for Section 3 and reports on four research projects.National Institutes of Health Grant R01 DC00194National Institutes of Health Grant P01 DC00119National Science Foundation Grant IBN 96-04642W.M. Keck Foundation Career Development ProfessorshipNational Institutes of Health Grant R01 DC00238Thomas and Gerd Perkins Award ProfessorshipAlfred P Sloan Foundation Instrumentation GrantJohn F. and Virginia B. Taplin Award in Health Sciences and TechnologyNational Institutes of Health/National Institute of Deafness and Other Communication DisordersNational Institutes of Health/National Institute of Deafness and Other Communication Disorders Grant PO1 DC0011
Signal Transmission in the Auditory System
Contains table of contents for Section 3, an introduction and reports on five research projects.National Institutes of Health Grant R01-DC-00194National Institutes of Health Grant P01-DC-00119Charles S. Draper Laboratory Contract DL-H-496015National Institutes of Health Grant R01 DC00238National Institutes of Health Grant R01-DC02258National Institutes of Health Grant T32-DC00038National Institutes of Health Grant RO1 DC00235National Institutes of Health Grant P01-DC00361National Institutes of Health Contract N01-DC-6-210
Signal Transmission in the Auditory System
Contains table of contents for Section 3, an introduction and reports on six research projects.National Institutes of Health Grant RO1-DC-00194-11National Institutes of Health Grant PO1-DC00119 Sub-Project 1National Institutes of Health Grant F32-DC00073-3National Institutes of Health Contract P01-DC00119National Institutes of Health Grant R01 DC00238National Institutes of Health Grant P01-DC00119National Institutes of Health Grant T32-DC00038National Institutes of Health Contract P01-DC00361National Institutes of Health Grant R01-DC00235National Institutes of Health Contract NO1-DC2240
Signal Transmission in the Auditory System
Contains table of contents for Section 3, an introduction and reports on seven research projects.National Institutes of Health Grant P01-DC-00119National Institutes of Health Grant R01-DC-00194National Institutes of Health Grant R01 DC00238National Institutes of Health Grant R01-DC02258National Institutes of Health Grant T32-DC00038National Institutes of Health Grant P01-DC00361National Institutes of Health Grant 2RO1 DC00235National Institutes of Health Contract N01-DC2240
Tunable Nanostructured Coating for the Capture and Selective Release of Viable Circulating Tumor Cells
A layer-by-layer gelatin nanocoating is presented for use as a tunable, dual response biomaterial for the capture and release of circulating tumor cells (CTCs) from cancer patient blood. The entire nanocoating can be dissolved from the surface of microfluidic devices through biologically compatible temperature shifts. Alternatively, individual CTCs can be released through locally applied mechanical stress
Recommended from our members
Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat
Wearable sweat sensors rely either on electronics for electrochemical detection or on colorimetry for visual readout. Non-ideal form factors represent disadvantages of the former, while semiquantitative operation and narrow scope of measurable biomarkers characterize the latter. Here, we introduce a battery-free, wireless electronic sensing platform inspired by biofuel cells that integrates chronometric microfluidic platforms with embedded colorimetric assays. The resulting sensors combine advantages of electronic and microfluidic functionality in a platform that is significantly lighter, cheaper, and smaller than alternatives. A demonstration device simultaneously monitors sweat rate/loss, pH, lactate, glucose, and chloride. Systematic studies of the electronics, microfluidics, and integration schemes establish the key design considerations and performance attributes. Two-day human trials that compare concentrations of glucose and lactate in sweat and blood suggest a potential basis for noninvasive, semi-quantitative tracking of physiological status.Air Force Research Laboratory (AFRL) Human Signatures Branch [FA8650-14-D-6516]; Soft and Hybrid Nanotechnology Experimental (SHyNE) Resource [NSF ECCS-1542205]; Materials Research Science and Engineering Center [DMR-1720139]; State of Illinois; Northwestern UniversityOpen access journalThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]