306 research outputs found
Recent neutronics developments for reactor safety studies with SIMMER code at KIT
The SIMMER family of codes is applied for safety studies of sodium fast reactors and reactors of other types. Both neutronics and fluid-dynamics parts of SIMMER are under development. In the paper new neutronics capabilities are presented. In particular developments for neutron transport solvers and a new technique for taking into account thermal expansion effects are described. These new capabilities facilitate 3D simulations and improve accuracy of modelling for the initiation transient phase during a hypothetical severe accident
Analytical Parametric Model Used to Study the Influence of Electrostatic Force on Surface Coverage During Electrospinning of Polymer Fibers
Electrospinning (ES) can readily produce polymer fibers with cross-sectional dimensions ranging from tens of nanometers to tens of microns. Qualitative estimates of surface area coverage are rather intuitive. However, quantitative analytical and numerical methods for predicting surface coverage during ES have not been covered in sufficient depth to be applied in the design of novel materials, surfaces, and devices from ES fibers. This article presents a modeling approach to ES surface coverage where an analytical model is derived for use in quantitative prediction of surface coverage of ES fibers. The analytical model is used to predict the diameter of circular deposition areas of constant field strength and constant electrostatic force. Experimental results of polyvinyl alcohol fibers are reported and compared to numerical models to supplement the analytical model derived. The analytical model provides scientists and engineers a method for estimating surface area coverage. Both applied voltage and capillary-to-collection-plate separation are treated as independent variables for the analysis. The electric field produced by the ES process was modeled using COMSOL Multiphysics software to determine a correlation between the applied field strength and the size of the deposition area of the ES fibers. MATLAB scripts were utilized to combine the numerical COMSOL results with derived analytical equations. Experimental results reinforce the parametric trends produced via modeling and lend credibility to the use of modeling techniques for the qualitative prediction of surface area coverage from ES. (Copyright: 2014 American Vacuum Society.
Gas-Modified Electrospinning with a Portable Device
Project Objective
The objective of this work was to construct a miniaturized, portable electrospinning (ES) device for deposition on surfaces regardless of charge.
We hope this device can be used by doctors in rural areas to deliver drug delivery bandages.
Mathematical modeling was used to improve predictability of the completed portable ES device
Deposition of Drug-delivering Bandages via a Combined Electrostatic and Air-Driven Electrospinning Device
Electrospinning (ES) is an affordable manufacturing process to produce nanoscale, polymer fibers.
During ES, a high voltage differential is required to draw out polymer fibers from a polymer solution at a charged spinneret.
Fibers produced are then deposited onto an oppositely charged electrode.
ES typically requires large, immovable equipment and conductive surfaces for deposition of fibers.
Portability and on-demand ES of fiber mats onto non-conductive surfaces would enable use in re- mote locations with limited access to medicine
Infrared Thermography in Symptomatic Knee Osteoarthritis: Joint Temperature Differs Based on Patient and Pain Characteristics
The aim of this study was to evaluate osteoarthritis (OA) patients with infrared thermography to investigate imaging patterns as well as demographic and clinical characteristics that influence knee inflammation. Forty patients with one-sided symptomatic knee OA were included and evaluated through knee-specific PROMs and the PainDETECT Questionnaire for neuropathic pain evaluation. Thermograms were captured using a thermographic camera FLIR-T1020 and temperatures were extracted using the software ResearchIR for the overall knee and the five ROIs: medial, lateral, medial patella, lateral patella, and suprapatellar. The mean temperature of the total knee was 31.9 ± 1.6 °C. It negatively correlated with age (rho = −0.380, p = 0.016) and positively correlated with BMI (rho = 0.421, p = 0.007) and the IKDC objective score (tau = 0.294, p = 0.016). Men had higher temperatures in the knee medial, lateral, and suprapatellar areas (p = 0.017, p = 0.019, p = 0.025, respectively). Patients with neuropathic pain had a lower temperature of the medial knee area (31.5 ± 1.0 vs. 32.3 ± 1.1, p = 0.042), with the total knee negatively correlating with PainDETECT (p = 0.045). This study demonstrated that the skin temperature of OA symptomatic knees is influenced by demographic and clinical characteristics of patients, with higher joint temperatures in younger male patients with higher BMI and worst objective knee scores and lower temperatures in patients affected by neuropathic pain
Complications of Tranexamic Acid in Orthopedic Lower Limb Surgery: A Meta-Analysis of Randomized Controlled Trials
Objective. Tranexamic acid (TXA) is increasingly used in orthopedic surgery to reduce blood loss; however, there are concerns about the risk of venous thromboembolic (VTE) complications. The aim of this study was to evaluate TXA safety in patients undergoing lower limb orthopedic surgical procedures. Design. A meta-analysis was performed on the PubMed, Web of Science, and Cochrane Library databases in January 2020 using the following string (Tranexamic acid) AND ((knee) OR (hip) OR (ankle) OR (lower limb)) to identify RCTs about TXA use in patients undergoing every kind of lower limb surgical orthopedic procedures, with IV, IA, or oral administration, and compared with a control arm to quantify the VTE complication rates. Results. A total of 140 articles documenting 9,067 patients receiving TXA were identified. Specifically, 82 studies focused on TKA, 41 on THA, and 17 on other surgeries, including anterior cruciate ligament reconstruction, intertrochanteric fractures, and meniscectomies. The intravenous TXA administration protocol was studied in 111 articles, the intra-articular in 45, and the oral one in 7 articles. No differences in terms of thromboembolic complications were detected between the TXA and control groups neither in the overall population (2.4% and 2.8%, respectively) nor in any subgroup based on the surgical procedure and TXA administration route. Conclusions. There is an increasing interest in TXA use, which has been recently broadened from the most common joint replacement procedures to the other types of surgeries. Overall, TXA did not increase the risk of VTE complications, regardless of the administration route, thus supporting the safety of using TXA for lower limb orthopedic surgical procedures
Classification Systems for Knee Osteochondritis Dissecans: A Systematic Review
Objective Aim of this systematic review was to describe all classification systems for knee osteochondritis dissecans (OCD) lesions, evaluating their accuracy and reliability, as well as their use in the literature on knee OCD. Design A systematic review of the literature was performed in July 2021 on PubMed, WebOfScience, and Cochrane Collaboration (library) to describe all published classification systems for knee OCD lesions and quantify the use of these classifications in the literature. Results Out of 1,664 records, 30 studies on 33 OCD classifications systems were identified, describing 11 radiographic, 13 MRI, and 9 arthroscopic classifications. The search included 193 clinical studies applying at least one OCD classification, for a total of 7,299 knee OCD cases. Radiographic classifications were applied to 35.8%, MRI to 35.2%, and arthroscopic classifications to 64.2% of the included studies. Among these, in the last two decades, the International Cartilage Repair Society's (ICRS) arthroscopic classification was the most described approach in studies on knee OCD. Overall, there is a lack of data on accuracy and reliability of the available systems. Conclusions Several classifications are available, with ICRS being the most used system over the time period studied. Arthroscopy allows to confirm lesion stability, but noninvasive imaging approaches are the first line to guide patient management. Among these, radiographic classifications are still widely used, despite being partially superseded by MRI, because of its capability to detect the earliest disease stages and to distinguish stable from unstable lesions, and thus to define the most suitable conservative or surgical approach to manage patients affected by knee OCD
Minimal Clinically Important Difference and Patient Acceptable Symptom State in Patients With Knee Osteoarthritis Treated With PRP Injection
Background: Although several injection-based treatments have been proposed to address knee osteoarthritis (OA), it is often difficult to understand the clinical relevance of the obtained results. The psychometric measures of minimal clinically important difference (MCID) and Patient Acceptable Symptom State (PASS) were developed to better interpret study findings. Purpose: To establish the MCID and the PASS for the International Knee Documentation Committee (IKDC) Subjective score and the Knee injury and Osteoarthritis Outcome Score (KOOS) in patients treated with intra-articular platelet-rich plasma (PRP) injections for knee OA. Study Design: Case series; Level of evidence, 4. Methods: This study included 215 patients with knee OA (68% men, 32% women; age, 53.2 ± 11.3 years; body mass index, 26.8 ± 4.3 kg/m2) who underwent intra-articular PRP injections. Patients were assessed through the IKDC Subjective score and KOOS subscales, and the MCID and the PASS for both measures were independently calculated at 6 and 12 months post-injection. The MCID was calculated using the value equal to half of the standard deviation of the overall cohort improvement. The PASS was assessed using a 2-point scale (satisfied or not satisfied), with threshold values being detected through a receiver operating characteristic curve analysis and the Youden index to maximize the sensitivity and the specificity of the threshold values. Results: All scores improved significantly from baseline to 6 months and baseline to 12 months (P <.001 for all scores). All scores were stable from 6 to 12 months except for the KOOS Quality of Life subscale, which improved further (P =.033). For the IKDC, the MCID values were 8.6 and 8.5 points and the PASS scores were 59.7 and 62.1 at 6 and 12 months, respectively. Overall, the MCID and the PASS for all KOOS subscales remained constant at the 2 follow-up points. The percentage of patients who achieved the MCID and the PASS was higher than 85% at both 6 and 12 months post-injection. Conclusion: This study provided the MCID and PASS thresholds for the IKDC and KOOS scores in patients with knee OA treated with PRP injections. These psychometric measures may allow a better interpretation of the clinical relevance of injection-based treatment outcomes for knee OA
- …