77 research outputs found

    An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study

    Get PDF
    Aims Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial. Methods and results Fifty-six consecutive patients underwent OCT during angiographic follow-up at 9 months. OCT images were acquired using a non-occlusive technique at a pullback speed of 3 mm/s. Data were analysed using a Bayesian hierarchical random-effects model, which accounted for the correlation of lesion characteristics within patients and implicitly assigned analytical weights to each lesion depending on the number of struts observed per lesion. Primary outcome was the difference in percentage of uncovered struts between BESs and SESs. Twenty patients were included in the analysis in the BES group (29 lesions with 4592 struts) and 26 patients in the SES group (35 lesions with 6476 struts). A total of 83 struts were uncovered in the BES group and 407 out of 6476 struts were uncovered in the SES group [weighted difference −1.4%, 95% confidence interval (CI) −3.7 to 0.0, P = 0.04]. Results were similar after adjustment for pre-procedure lesion length, reference vessel diameter, number of implanted study stents, and presence of stent overlap. There were three lesions in the BES group and 15 lesions in the SES group that had ≥5% of all struts uncovered (difference −33.1%, 95% CI −61.7 to −10.3, P < 0.01). Conclusion Strut coverage at an average follow-up of 9 months appears to be more complete in patients allocated to BESs when compared with SESs. The impact of this difference on clinical outcome and, in particular, on the risk of late stent thrombosis is yet to be determine

    Significant reduction in restenosis after the use of sirolimus-eluting stents in the treatment of chronic total occlusions

    Get PDF
    AbstractObjectivesThe aim of this study was to assess sirolimus-eluting stent (SES) implantation for the treatment of chronic total coronary occlusions (CTO).BackgroundLong-term results after percutaneous coronary intervention (PCI) in the treatment of CTOs is hindered by a significant rate of restenosis and reocclusion. In the treatment of relatively simple nonocclusive lesions, SESs have shown dramatically reduced restenosis rates compared with bare metal stents (BMS), but whether these results are more widely applicable is unknown.MethodsFrom April 2002, all patients at our institution were treated with SES as the device of choice during PCI. During the first six months, 563 patients were treated solely with SES, with treatment of a de novo CTO in 56 (9.9%). This CTO cohort was compared with a similar group of patients (n = 28) treated in the preceding six-month period with BMS.ResultsAt one year, the cumulative survival-free of major adverse cardiac events was 96.4% in the SES group versus 82.8% in the BMS group, p < 0.05. At six-month follow-up, 33 (59%) patients in the SES group underwent angiography with a binary restenosis rate (>50% diameter stenosis) of 9.1% and in-stent late loss of 0.13 ± 0.46 mm. One patient (3.0%) at follow-up was found to have reoccluded the target vessel.ConclusionsThe use of SESs in the treatment of chronic total coronary occlusions is associated with a reduction in the rate of major adverse cardiac events and restenosis compared with BMS

    Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial

    Get PDF
    Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-u

    Short- and long-term clinical benefit of sirolimus-eluting stents compared to conventional bare stents for patients with acute myocardial infarction

    Get PDF
    AbstractObjectivesThis study investigated the clinical outcomes of patients with ST-segment elevation myocardial infarction (MI) treated with sirolimus-eluting stents (SESs) or with conventional bare stents.BackgroundThe clinical impact of SES implantation for patients with ST-segment elevation MI is currently unknown.MethodsPrimary angioplasty was performed with SESs in 186 consecutive patients with acute MI who were compared with 183 patients treated with bare stents. The incidence of death, reinfarction, and repeat revascularization was assessed at 30 and 300 days.ResultsPostprocedure vessel patency, enzymatic release, and the incidence of short-term adverse events were similar in both the sirolimus and the bare stents (30-day rate of death, reinfarction, or repeat revascularization: 7.5% vs. 10.4%, respectively; p = 0.4). Stent thrombosis was not diagnosed in any patient in the sirolimus group and occurred in 1.6% of patients treated with bare stents (p = 0.1). At 300 days, treatment with SESs significantly reduced the incidence of combined adverse events (9.4% vs. 17%; hazard ratio [HR] 0.52 [95% confidence interval (CI) 0.30 to 0.92]; p = 0.02), mainly due to a marked reduction in the risk of repeat intervention (1.1% vs. 8.2%; HR 0.21 [95% CI 0.06 to 0.74]; p = 0.01).ConclusionsCompared to conventional bare stents, the SESs were not associated with an increased risk of stent thrombosis and were effective in reducing the incidence of adverse events at 300 days in unselected patients with ST-segment elevation acute MI referred for primary angioplasty

    Intermittent pacing therapy favorably modulates infarct remodeling

    Get PDF
    textabstractDespite early revascularization, remodeling and dysfunction of the left ventricle (LV) after acute myocardial infarction (AMI) remain important therapeutic targets. Intermittent pacing therapy (IPT) of the LV can limit infarct size, when applied during early reperfusion. However, the effects of IPT on post-AMI LV remodeling and infarct healing are unknown. We therefore investigated the effects of IPT on global LV remodeling and infarct geometry in swine with a 3-day old AMI. For this purpose, fifteen pigs underwent 2 h ligation of the left circumflex coronary artery followed by reperfusion. An epicardial pacing lead was implanted in the peri-infarct zone. After three days, global LV remodeling and infarct geometry were assessed using magnetic resonance imaging (MRI). Animals were stratified into MI control and IPT groups. Thirty-five days post-AMI, follow-up MRI was obtained and myofibroblast content, markers of extracellular matrix (ECM) turnover and Wnt/frizzled signaling in infarct and non-infarct control tissue were studied. Results showed that IPT had no significant effect on global LV remodeling, function or infarct mass, but modulated infarct healing. In MI control pigs, infarct mass reduction was principally due to a 26.2 ± 4.4% reduction in infarct thickness (P ≤ 0.05), whereas in IPT pigs it was mainly due to a 35.7 ± 4.5% decrease in the number of infarct segments (P ≤ 0.05), with no significant change in infarct thickness. Myofibroblast content of the infarct zone was higher in IPT (10.9 ± 2.1%) compared to MI control (5.4 ± 1.6%; P ≤ 0.05). Higher myofibroblast presence did not coincide with alterations in expression of genes involved in ECM turnover or Wnt/frizzled signaling at 5 weeks follow-up. Taken together, IPT limited infarct expansion and altered infarct composition, showing that IPT influences remodeling of the infarct zone, likely by increasing regional myofibroblast content

    Coronary stent coatings

    No full text
    Stents should be regarded as intravascular foreign bodies, and therefore two equally important issues, blood compatibility and tissue compatibility, need to be addressed when designing or modifying stents. An implant is considered 'blood-compatible' when it induces only mild activation of coagulation proteins and platelets, and is considered 'tissue-compatible' when it does not interfere with wound healing and does not induce either excessive cell proliferation or chronic inflammation. Given that thrombosis is an integral and essential part of wound healing, blood and tissue compatibility are closely inter-related. [...]This paper is divided into three parts. The first part deals with general principles governing blood in contact with a foreign (stent) surface. The second part deals with the several approaches to changing stent characteristics, with emphasis on stent coatings. In the third part, experimental data illustrating each of the approaches will be presented.<br/

    Coronary stent coatings

    No full text
    Stents should be regarded as intravascular foreign bodies, and therefore two equally important issues, blood compatibility and tissue compatibility, need to be addressed when designing or modifying stents. An implant is considered 'blood-compatible' when it induces only mild activation of coagulation proteins and platelets, and is considered 'tissue-compatible' when it does not interfere with wound healing and does not induce either excessive cell proliferation or chronic inflammation. Given that thrombosis is an integral and essential part of wound healing, blood and tissue compatibility are closely inter-related. [...]This paper is divided into three parts. The first part deals with general principles governing blood in contact with a foreign (stent) surface. The second part deals with the several approaches to changing stent characteristics, with emphasis on stent coatings. In the third part, experimental data illustrating each of the approaches will be presented.<br/
    • …
    corecore