184 research outputs found

    Thinner Regions of Intracranial Aneurysm Wall Correlate with Regions of Higher Wall Shear Stress: A 7T MRI Study

    Get PDF
    BACKGROUND AND PURPOSE: Both hemodynamics and aneurysm wall thickness are important parameters in aneurysm pathophysiology. Our aim was to develop a method for semi-quantitative wall thickness assessment on in vivo 7T MR images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. MATERIALS AND METHODS: Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients who underwent 7T MR imaging with a TSE-based vessel wall sequence (0.8-mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to the signal of nearby brain tissue and were used as measures of apparent wall thickness. Spatial wall thickness variation was determined as the interquartile range in apparent wall thickness (the middle 50% of the apparent wall thickness range). Wall shear stress was determined by using phase-contrast MR imaging (0.5-mm isotropic resolution). We performed visual and statistical comparisons (Pearson correlation) to study the relation between wall thickness and wall shear stress. RESULTS: 3D colored apparent wall thickness maps of the aneurysms showed spatial apparent wall thickness variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of 1 voxel [0.8 mm]). In all aneurysms, apparent wall thickness was inversely related to wall shear stress (mean correlation coefficient, −0.35; P < .05). CONCLUSIONS: A method was developed to measure the wall thickness semi-quantitatively, by using 7T MR imaging. An inverse correlation between wall shear stress and apparent wall thickness was determined. In future studies, this noninvasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and rupture

    Plasma deposition of Ultrathin polymer films on carbon nanotubes

    Full text link
    Ultrathin films of pyrrole were deposited on the surfaces of carbon nanotubes using a plasma polymerization treatment. High-resolution electron transmission microscopy images revealed that an extremely thin film of the polymer layer (2 ∼ 7 nm)(2∼7nm) was uniformly deposited on the outer and inner surfaces of the nanotubes. The nanotubes of all sizes exhibited equally uniform ultrathin films, indicating well-dispersed nanotubes in the fluidized bed reactor during the plasma treatment. In particular, the inner wall of the nanotube was also coated with a uniform ultrathin film of only ∼1–3 nm. Time-of-flight secondary ion mass spectroscopy experiments confirmed the highly branched and cross-linked polymer thin films on the carbon nanotubes. The plasma deposition mechanism is discussed in this letter. © 2002 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/71075/2/APPLAB-81-27-5216-1.pd

    Adjacent level discitis after anterior cervical discectomy and fusion (ACDF): a case report

    Get PDF
    This report describes a case of spondylodiscitis occurring adjacent to levels at which anterior cervical discectomy and fusion was performed. The objective is to describe a rare cause of spondylodiscitis and discuss its successful management. Post-operative discitis involving the same level is a known occurrence. We report an interesting case of spondylodiscitis occurring at the adjacent level of fusion, and to our knowledge this is the first such case reported in literature. A two-level decompression and fusion was performed at C5–6 and C6–7 levels with PEEK cages and anterior cervical plating in a middle-aged gentleman for persistent axial neck pain and left-sided radiculopathy involving C6 and C7 distribution. After 6 weeks, the patient presented to us with complaints of mild paresthesia in the abdomen and extremities. Radiological investigations including plain radiographs and MRI revealed a surprising finding of discitis at C4–5 level with an associated epidural abscess. In view of the patient’s myelopathic symptoms, surgical debridement and decompression of the spinal cord was performed. The plate and screws were removed, the cages were left intact, and the C4–5 disc level was reconstructed with tricortical iliac crest autograft. No further instrumentation was performed. The biopsy specimen from the disc at C4–5 level grew Serratia marcescens. It was contemplated that C4–5 discitis was initiated by inoculation of bacteria at the superior endplate of C5 by contaminated vertebral pins/drill-bit or screws. Adjacent level discitis is a rare but potentially serious complication of anterior cervical fusion. A high index of suspicion of infection is necessary if the patient complains of new symptoms after anterior cervical fusion. Thorough assessment and aggressive treatment is necessary for successful management

    New Insight in Loss of Gut Barrier during Major Non-Abdominal Surgery

    Get PDF
    PG - e3954 AB - BACKGROUND: Gut barrier loss has been implicated as a critical event in the occurrence of postoperative complications. We aimed to study the development of gut barrier loss in patients undergoing major non-abdominal surgery. METHODOLOGY/PRINCIPAL FINDINGS: Twenty consecutive children undergoing spinal fusion surgery were included. This kind of surgery is characterized by long operation time, significant blood loss, prolonged systemic hypotension, without directly leading to compromise of the intestines by intestinal manipulation or use of extracorporeal circulation. Blood was collected preoperatively, every two hours during surgery and 2, 4, 15 and 24 hours postoperatively. Gut mucosal barrier was assessed by plasma markers for enterocyte damage (I-FABP, I-BABP) and urinary presence of tight junction protein claudin-3. Intestinal mucosal perfusion was measured by gastric tonometry (P(r)CO2, P(r-a)CO2-gap). Plasma concentration of I-FABP, I-BABP and urinary expression of claudin-3 increased rapidly and significantly after the onset of surgery in most children. Postoperatively, all markers decreased promptly towards baseline values together with normalisation of MAP. Plasma levels of I-FABP, I-BABP were significantly negatively correlated with MAP at (1/2) hour before blood sampling (-0.726 (p<0.001), -0.483 (P<0.001), respectively). Furthermore, circulating I-FABP correlated with gastric mucosal P(r)CO2, P(r-a)CO2-gap measured at the same time points (0.553 (p = 0.040), 0.585 (p = 0.028), respectively). CONCLUSIONS/SIGNIFICANCE: This study shows the development of gut barrier loss in children undergoing major non-abdominal surgery, which is related to preceding hypotension and mesenterial hypoperfusion. These data shed new light on the potential role of peroperative circulatory perturbation and intestinal barrier los
    corecore