26 research outputs found

    Safety, acceptability and adherence of dapivirine vaginal ring in a microbicide clinical trial conducted in multiple countries in sub-Saharan Africa

    Get PDF
    BACKGROUND: This was the first microbicide trial conducted in Africa to evaluate an antiretroviral-containing vaginal ring as an HIV prevention technology for women. Objectives The trial assessed and compared the safety, acceptability and adherence to product use of a 4-weekly administered vaginal ring containing the antiretroviral microbicide, dapivirine, with a matching placebo ring among women from four countries in sub-Saharan Africa. METHODS: 280 Healthy, sexually active, HIV-negative women, aged 18 to 40 years were enrolled with 140 women randomised to a dapivirine vaginal ring (25 mg) and 140 women to a matching placebo ring, inserted 4-weekly and used over a 12-week period. Safety was evaluated by pelvic examination, colposcopy, clinical laboratory assessments, and adverse events. Blood samples for determination of plasma concentrations of dapivirine were collected at Weeks 0, 4 and 12. Residual dapivirine levels in returned rings from dapivirine ring users were determined post-trial. Participant acceptability and adherence to ring use were assessed by self-reports. RESULTS: No safety concerns or clinically relevant differences were observed between the dapivirine and placebo ring groups. Plasma dapivirine concentrations immediately prior to ring removal were similar after removal of the first and third ring, suggesting consistent ring use over the 12-week period. No clear relationship was observed between the residual amount of dapivirine in used rings and corresponding plasma concentrations. Self-reported adherence to daily use of the vaginal rings over the 12-week trial period was very high. At the end of the trial, 96% of participants reported that the ring was usually comfortable to wear, and 97% reported that they would be willing to use it in the future if proven effective. CONCLUSIONS: The dapivirine vaginal ring has a favourable safety and acceptability profile. If proven safe and effective in large-scale trials, it will be an important component of combination HIV prevention approaches for women. Trial Registration ClinicalTrials.gov NCT0107117

    HIV Incidence Remains High in KwaZulu-Natal, South Africa: Evidence from Three Districts

    Get PDF
    Background: HIV prevalence and incidence among sexually active women in peri-urban areas of Ladysmith, Edendale, and Pinetown, KwaZulu-Natal, South Africa, were assessed between October 2007 and February 2010 in preparation for vaginal microbicide trials. Methodology/Principal Findings: Sexually active women 18-35 years, not known to be HIV-positive or pregnant were tested cross-sectionally to determine HIV and pregnancy prevalence (798 in Ladysmith, 1,084 in Edendale, and 891 in Pinetown). Out of these, approximately 300 confirmed non-pregnant, HIV-negative women were subsequently enrolled at each clinical research center (CRC) in a 12-month cohort study with quarterly study visits. Women in the cohort studies were required to use a condom plus a hormonal contraceptive method. HIV prevalence rates in the baseline cross-sectional surveys were high: 42% in Ladysmith, 46% in Edendale and 41% in Pinetown. Around 90% of study participants at each CRC reported one sex partner in the last 3 months, but only 14-30% stated that they were sure that none of their sex partners were HIV-positive. HIV incidence rates based on seroconversions over 12 months were 14.8/100 person-years (PY) (95% CI 9.7, 19.8) in Ladysmith, 6.3/100 PY (95% CI 3.2, 9.4) in Edendale, and 7.2/100 PY (95% CI 3.7, 10.7) in Pinetown. The 12-month pregnancy incidence rates (in the context of high reported contraceptive use) were: 5.7/100 PY (95% CI 2.6, 8.7) in Ladysmith, 3.1/100 PY (95% CI 0.9, 5.2) in Edendale and 6.3/100 PY (95% CI 3.0, 9.6) in Pinetown. Conclusions/Significance: HIV prevalence and incidence remain high in peri-urban areas of KwaZulu-Nata

    Safety and Efficacy of a Dapivirine Vaginal Ring for HIV Prevention in Women.

    Get PDF
    BACKGROUND: The incidence of human immunodeficiency virus (HIV) infection remains high among women in sub-Saharan Africa. We evaluated the safety and efficacy of extended use of a vaginal ring containing dapivirine for the prevention of HIV infection in 1959 healthy, sexually active women, 18 to 45 years of age, from seven communities in South Africa and Uganda. METHODS: In this randomized, double-blind, placebo-controlled, phase 3 trial, we randomly assigned participants in a 2:1 ratio to receive vaginal rings containing either 25 mg of dapivirine or placebo. Participants inserted the rings themselves every 4 weeks for up to 24 months. The primary efficacy end point was the rate of HIV type 1 (HIV-1) seroconversion. RESULTS: A total of 77 participants in the dapivirine group underwent HIV-1 seroconversion during 1888 person-years of follow-up (4.1 seroconversions per 100 person-years), as compared with 56 in the placebo group who underwent HIV-1 seroconversion during 917 person-years of follow-up (6.1 seroconversions per 100 person-years). The incidence of HIV-1 infection was 31% lower in the dapivirine group than in the placebo group (hazard ratio, 0.69; 95% confidence interval [CI], 0.49 to 0.99; P=0.04). There was no significant difference in efficacy of the dapivirine ring among women older than 21 years of age (hazard ratio for infection, 0.63; 95% CI, 0.41 to 0.97) and those 21 years of age or younger (hazard ratio, 0.85; 95% CI, 0.45 to 1.60; P=0.43 for treatment-by-age interaction). Among participants with HIV-1 infection, nonnucleoside reverse-transcriptase inhibitor resistance mutations were detected in 14 of 77 participants in the dapivirine group (18.2%) and in 9 of 56 (16.1%) in the placebo group. Serious adverse events occurred more often in the dapivirine group (in 38 participants [2.9%]) than in the placebo group (in 6 [0.9%]). However, no clear pattern was identified. CONCLUSIONS: Among women in sub-Saharan Africa, the dapivirine ring was not associated with any safety concerns and was associated with a rate of acquisition of HIV-1 infection that was lower than the rate with placebo. (Funded by the International Partnership for Microbicides; ClinicalTrials.gov number, NCT01539226 .)

    Safety of a silicone elastomer vaginal ring as potential microbicide delivery method in African women: A Phase 1 randomized trial

    No full text
    <div><p>Background</p><p>Women in sub-Saharan Africa are in urgent need of female-initiated human immunodeficiency virus (HIV) preventative methods. Vaginal rings are one dosage form in development for delivery of HIV microbicides. However, African women have limited experience with vaginal rings.</p><p>Objectives</p><p>This Phase I, randomized, crossover trial assessed and compared the safety, acceptability and adherence of a silicone elastomer placebo vaginal ring, intended as a microbicide delivery method, inserted for a 12-week period in healthy, HIV-negative, sexually active women in South Africa and Tanzania.</p><p>Methods</p><p>170 women, aged 18 to 35 years were enrolled with 88 women randomized to Group A, using a placebo vaginal ring for 12 weeks followed by a 12-week safety observation period. 82 women were randomized to Group B and observed for safety first, followed by a placebo vaginal ring for 12 weeks. Safety was assessed by clinical laboratory assessments, pelvic/colposcopy examinations and adverse events. Possible carry-over effect was addressed by ensuring no signs or symptoms of genital irritation at crossover.</p><p>Results</p><p>No safety concerns were identified for any safety variables assessed during the trial. No serious adverse events were reported considered related to the placebo vaginal ring. Vaginal candidiasis was the most common adverse event occurring in 11% of participants during each trial period. Vaginal discharge (2%), vaginal odour (2%), and bacterial vaginitis (2%) were assessed as possibly or probably related to the vaginal ring. Thirty-four percent of participants had sexually transmitted infections (STIs) at screening, compared to 12% of participants who tested positive for STIs at crossover and the final trial visit. Three participants (2%) tested HIV positive during the trial.</p><p>Conclusions</p><p>The silicone elastomer vaginal ring had no safety concerns, demonstrating a profile favorable for further development for topical release of antiretroviral-based microbicides.</p></div

    Trial design and overview of safety assessments.

    No full text
    <p>Group A: Participants in this group participated in a placebo vaginal ring regimen for the first 12 weeks of the trial where after they crossed over to a 12-week observational period without a ring. Group B: Participants in this group participated in an observational period for the first 12 weeks of the trial where after they crossed over to a 12-week placebo vaginal ring period. A = Group A; B = Group B, Colpo = colposcopic examination; HCG = human chorionic gonadotropin; HIV = human immunodeficiency virus; Pelvic = pelvic examination; Quest = questionnaire; Scrn = screening; STI = sexually transmitted infection; TEAE = treatment emergent adverse event.</p
    corecore