6 research outputs found

    Clinical impact of molecular breast imaging as adjunct diagnostic modality in evaluation of indeterminate breast abnormalities and unresolved diagnostic concerns

    Get PDF
    Purpose Improvements in molecular breast imaging (MBI) have increased the use of MBI as adjunct diagnostic modality and alternative to MRI. We aimed to assess the value of MBI in patients with equivocal breast lesions on conventional imaging, especially in terms of its ability to rule out malignancy. Methods We selected patients who underwent MBI in addition to conventional diagnostics due to equivocal breast lesions between 2012 and 2015. All patients underwent digital mammography, target ultrasound and MBI. MBI was performed using a single-head Dilon 6800 gamma camera after administration of 600 MBq 99mTc-sestamibi. Imaging was reported according to BI-RADS classification and compared with pathology or follow-up of ≥6 months. Results Of 226 women included, pathology was obtained in 106 (47%) and (pre)malignant lesions were found in 25 (11%). Median follow-up was 5.4 years (IQR 3.9-7.1). Sensitivity was higher for MBI compared to conventional diagnostics (84% vs. 32%; P = 0.002), identifying malignancy in 21 and 6 patients, respectively, but specificity did not differ (86% vs. 81%; P = 0.161). Positive and negative predictive value were 43% and 98% for MBI and 17% and 91% for conventional diagnostics. MBI was discordant with conventional diagnostics in 68 (30%) patients and correctly changed diagnosis in 46 (20%) patients, identifying 15 malignant lesions. In subgroups with nipple discharge (N = 42) and BI-RADS 3 lesions (N = 113) MBI detected 7 of 8 occult malignancies. Conclusion MBI correctly adjusted treatment in 20% of patients with diagnostic concerns after conventional work-up, and could rule out malignancy with a high negative predictive value of 98%.</p

    Minimally invasive complete response assessment of the breast after neoadjuvant systemic therapy for early breast cancer (micra trial) : interim analysis of a multicenter observational cohort study

    Get PDF
    Background The added value of surgery in breast cancer patients with pathological complete response (pCR) after neoadjuvant systemic therapy (NST) is uncertain. The accuracy of imaging identifying pCR for omission of surgery, however, is insufficient. We investigated the accuracy of ultrasound-guided biopsies identifying breast pCR (ypT0) after NST in patients with radiological partial (rPR) or complete response (rCR) on MRI. Methods We performed a multicenter, prospective single-arm study in three Dutch hospitals. Patients with T1-4(N0 or N +) breast cancer with MRI rPR and enhancement <= 2.0 cm or MRI rCR after NST were enrolled. Eight ultrasound-guided 14-G core biopsies were obtained in the operating room before surgery close to the marker placed centrally in the tumor area at diagnosis (no attempt was made to remove the marker), and compared with the surgical specimen of the breast. Primary outcome was the false-negative rate (FNR). Results Between April 2016 and June 2019, 202 patients fulfilled eligibility criteria. Pre-surgical biopsies were obtained in 167 patients, of whom 136 had rCR and 31 had rPR on MRI. Forty-three (26%) tumors were hormone receptor (HR)-positive/HER2-negative, 64 (38%) were HER2-positive, and 60 (36%) were triple-negative. Eighty-nine patients had pCR (53%; 95% CI 45-61) and 78 had residual disease. Biopsies were false-negative in 29 (37%; 95% CI 27-49) of 78 patients. The multivariable associated with false-negative biopsies was rCR (FNR 47%; OR 9.81, 95% CI 1.72-55.89; p = 0.01); a trend was observed for HR-negative tumors (FNR 71% in HER2-positive and 55% in triple-negative tumors; OR 4.55, 95% CI 0.95-21.73; p = 0.058) and smaller pathological lesions (6 mm vs 15 mm; OR 0.93, 95% CI 0.87-1.00; p = 0.051). Conclusion The MICRA trial showed that ultrasound-guided core biopsies are not accurate enough to identify breast pCR in patients with good response on MRI after NST. Therefore, breast surgery cannot safely be omitted relying on the results of core biopsies in these patients

    Immediate or delayed oncoplastic surgery after breast conserving surgery at the Netherlands Cancer Institute:a cohort study of 251 cases

    No full text
    Purpose: Oncoplastic surgery (OPS) after breast conserving surgery is preferably performed during the same operation. Offering delayed OPS instead of mastectomy to patients with a high risk of tumor-positive margins allows breast conservation with the option of margin re-excision during OPS, without having to dismantle the reconstruction. We aimed to evaluate surgical outcomes after immediate and delayed OPS. Methods: We included early-stage breast cancer patients who underwent OPS at the Netherlands Cancer Institute between 2016 and 2019. Patients were selected for delayed OPS after multidisciplinary consultation if the risk of tumor-positive margins with immediate OPS was considered significant (&gt; 30%). Groups were compared on baseline characteristics and short-term surgical outcomes. Results: Of 242 patients with 251 OPS, 130 (52%) OPS had neoadjuvant chemotherapy. Immediate OPS was performed in 176 (70%) cases and delayed OPS in 76 (30%). Selection for delayed OPS was associated with tumor size (OR 1.03, 95% CI 1.01–1.04), ILC (OR 2.61, 95% CI 1.10–6.20), DCIS (OR 3.45, 95% CI 1.42–8.34) and bra size (OR 0.76, 95% CI 0.62–0.94). Delayed and immediate OPS differed in tissue weight (54 vs. 67 g, p = 0.034), tissue replacement (51% vs. 26%, p &lt;.001) and tumor-positive margins (66% vs. 18%, p &lt;.001). Re-excision was performed in 48 (63%) delayed OPS and in 11 (6%) immediate OPS. Groups did not differ in complications (21% vs. 18%, p = 0.333). Breast conservation after immediate and delayed OPS was 98% and 93%, respectively. Conclusion: Performing delayed OPS in selected cases facilitated simultaneous margin re-excision without increasing complications, and resulted in an excellent breast conservation rate.</p

    Minimally Invasive Complete Response Assessment of the Breast After Neoadjuvant Systemic Therapy for Early Breast Cancer (MICRA trial): Interim Analysis of a Multicenter Observational Cohort Study

    No full text
    Background: The added value of surgery in breast cancer patients with pathological complete response (pCR) after neoadjuvant systemic therapy (NST) is uncertain. The accuracy of imaging identifying pCR for omission of surgery, however, is insufficient. We investigated the accuracy of ultrasound-guided biopsies identifying breast pCR (ypT0) after NST in patients with radiological partial (rPR) or complete response (rCR) on MRI. Methods: We performed a multicenter, prospective single-arm study in three Dutch hospitals. Patients with T1–4(N0 or N +) breast cancer with MRI rPR and enhancement ≤ 2.0 cm or MRI rCR after NST were enrolled. Eight ultrasound-guided 14-G core biopsies were obtained in the operating room before surgery close to the marker placed centrally in the tumor area at diagnosis (no attempt was made to remove the marker), and compared with the surgical specimen of the breast. Primary outcome was the false-negative rate (FNR). Results: Between April 2016 and June 2019, 202 patients fulfilled eligibility criteria. Pre-surgical biopsies were obtained in 167 patients, of whom 136 had rCR and 31 had rPR on MRI. Forty-three (26%) tumors were hormone receptor (HR)-positive/HER2-negative, 64 (38%) were HER2-positive, and 60 (36%) were triple-negative. Eighty-nine patients had pCR (53%; 95% CI 45–61) and 78 had residual disease. Biopsies were false-negative in 29 (37%; 95% CI 27–49) of 78 patients. The multivariable associated with false-negative biopsies was rCR (FNR 47%; OR 9.81, 95% CI 1.72–55.89; p = 0.01); a trend was observed for HR-negative tumors (FNR 71% in HER2-positive and 55% in triple-negative tumors; OR 4.55, 95% CI 0.95–21.73; p = 0.058) and smaller pathological lesions (6 mm vs 15 mm; OR 0.93, 95% CI 0.87–1.00; p = 0.051). Conclusion: The MICRA trial showed that ultrasound-guided core biopsies are not accurate enough to identify breast pCR in patients with good response on MRI after NST. Therefore, breast surgery cannot safely be omitted relying on the results of core biopsies in these patients
    corecore