38 research outputs found

    Left ventricular deformation and myocardial fibrosis in pediatric patients with Duchenne muscular dystrophy

    Get PDF
    Background: Left ventricular (LV) strain and rotation are emerging functional markers for early detection of LV dysfunction and have been associated with the burden of myocardial fibrosis in several disease states. This study examined the association between LV deformation (i.e., LV strain and rotation) and extent and location of LV myocardial fibrosis in pediatric patients with Duchenne muscular dystrophy (DMD). Methods and results: 34 pediatric patients with DMD underwent cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) to assess LV myocardial fibrosis. Offline CMR feature-tracking analysis was used to assess global and segmental longitudinal and circumferential LV strain, and LV rotation. Patients with fibrosis (n = 18, 52.9%) were older than those without fibrosis (14 ± 3 years (yrs) vs 11 ± 2 yrs., p = 0.01). There was no significant difference in LV ejection fraction (LVEF) between subjects with and without fibrosis (54 ± 6% vs 56 ± 4%, p = 0.18). However, lower endocardial global circumferential strain (GCS), but not LV rotation, was associated with presence of fibrosis (adjusted Odds Ratio 1.25 [95% CI 1.01–1.56], p = 0.04). Both GCS and global longitudinal strain correlated with the extent of fibrosis (r =.52, p = 0.03 and r =.75, p &lt; 0.01, respectively). Importantly, segmental strain did not seem to correspond to location of fibrosis. Conclusion: A lower global, but not segmental, strain is associated with presence and extent of LV myocardial fibrosis in pediatric DMD patients. Therefore, strain parameters might detect structural myocardial alterations, however currently more research is needed to evaluate its value (e.g., prognostic) in clinical practice.</p

    Reduction of blood culture contamination rate by an educational intervention

    Get PDF
    Background: Although mechanical dyssynchrony parameters derived by speckle tracking echocardiography (STE) may predict response to cardiac resynchronization therapy (CRT), comparability of parameters derived with different STE vendors is unknown. Methods: In the MARC study, echocardiographic images of heart failure patients obtained before CRT implantation were prospectively analysed with vendor specific STE software (GE EchoPac and Philips QLAB) and vendor-independent software (TomTec 2DCPA). Response was defined as change in left ventricular (LV) end-systolic volume between examination before and six-months after CRT implantation. Basic longitudinal strain and mechanical dyssynchrony parameters (septal to lateral wall delay (SL-delay), septal systolic rebound stretch (SRSsept), and systolic stretch index (SSI)) were obtained from either separate septal and lateral walls, or total LV apical four chamber. Septal strain patterns were categorized in three types. The coefficient of variation and intra-class correlation coefficient (ICC) were analysed. Dyssynchrony parameters were associated with CRT response using univariate regression analysis and C-statistics. Results: Two-hundred eleven patients were analysed. GE-cohort (n = 123): age 68 years (interquartile range (IQR): 61-73), 67% male, QRS-duration 177ms (IQR: 160-192), LV ejection fraction: 26 +/- 7%. Philips-cohort (n = 88): age 67 years (IQR: 59-74), 60% male, QRS-duration: 179 ms (IQR: 166-193), LV ejection fraction: 27 +/- 8. LV derived peak strain was comparable in the GE-(GE: -7.3 +/- 3.1%, TomTec: -6.4 +/- 2.8%, ICC: 0.723) and Philips-cohort (Philips: -7.7 +/- 2.7%, TomTec: -7.7 +/- 3.3%, ICC: 0.749). SL-delay showed low ICC values (GE vs. TomTec: 0.078 and Philips vs. TomTec: 0.025). ICC's of SRSsept and SSI were higher but only weak (GE vs. TomTec: SRSsept: 0.470, SSI: 0.467) (Philips vs. QLAB: SRSsept: 0.419, SSI: 0.421). Comparability of septal strain patterns was low (Cohen's kappa, GE vs. TomTec: 0.221 and Philips vs. TomTec: 0.279). Septal strain patterns, SRSsept and SSI were associated with changes in LV end-systolic volume for all vendors. SRSsept and SSI had relative varying C-statistic values (range: 0.530-0.705) and different cut-off values between vendors. Conclusions: Although global longitudinal strain analysis showed fair comparability, assessment of dyssynchrony parameters was vendor specific and not applicable outside the context of the implemented platform. While the standardization taskforce took an important step for global peak strain, further standardization of STE is still warranted

    Prognostic implications of invasive hemodynamics during cardiac resynchronization therapy: Stroke work outperforms dP/dt max.

    Get PDF
    Background: Invasive measurements of left ventricular (LV) hemodynamic performance can evaluate acute response to cardiac resynchronization therapy (CRT). Objective: The study sought to determine which metric, maximum rate of LV pressure rise (LV dP/dtmax) or LV stroke work (LVSW), is more strongly associated with long-term prognosis. Methods: CRT patients were prospectively included from 3 academic centers. Invasive pressure-volume loop measurements during implantation were performed, and LV dP/dtmax and LVSW were determined at baseline and during biventricular pacing (BVP) as well as their relative increase (%Δ). Hazard ratios (HRs) for the primary outcome of 8-year all-cause mortality were derived using Cox proportional hazards. The secondary endpoint was echocardiographic response, defined as 6-month LV end-systolic volume reduction ≥15%. Results: Paired data from 82 patients were analyzed (67% male; age 66 ± 9 years; QRS duration 158 ± 22 ms, median survival time 72 months). Survival was better when LVSW during BVP was ≥4400 mL∙mm Hg (HR 0.21, 95% CI 0.08–0.58, P .05), significant associations with echocardiographic response were found for stroke work during BVP (area under the receiver-operating characteristic curve 0.745, P = .001) and ΔLVSW% (area under the receiver-operating characteristic curve 0.803, P < .001). Conclusion: Stroke work, but not LV dP/dtmax, is consistently associated with long-term prognosis and response after CRT. Our results therefore favor the use of stroke work as the hemodynamic parameter to predict long-term outcome after CRT

    Perceptions of involvement in advance care planning and emotional functioning in patients with advanced cancer

    Get PDF
    Purpose: Advance Care Planning (ACP) is positively associated with the quality of care, but its impact on emotional functioning is ambiguous. This study investigated the association between perceptions of ACP involvement and emotional functioning in patients with advanced cancer. Methods: This study analyzed baseline data of 1,001 patients of the eQuiPe study, a prospective, longitudinal, multicenter, observational study on quality of care and quality of life in patients with advanced cancer in the Netherlands. Patients with metastatic solid cancer were asked to participate between November 2017 and January 2020. Patients’ perceptions of ACP involvement were measured by three self-administered statements. Emotional functioning was measured by the EORTC-QLQ-C30. A linear multivariable regression analysis was performed while taking gender, age, migrant background, education, marital status, and symptom burden into account. Results: The majority of patients (87%) reported that they were as much involved as they wanted to be in decisions about their future medical treatment and care. Most patients felt that their relatives (81%) and physicians (75%) were familiar with their preferences for future medical treatment and care. A positive association was found between patients’ perceptions of ACP involvement and their emotional functioning (b=0.162, p<0.001, 95%CI[0.095;0.229]) while controlling for relevant confounders. Conclusions: Perceptions of involvement in ACP are positively associated with emotional functioning in patients with advanced cancer. Future studies are needed to further investigate the effect of ACP on emotional functioning. Trial registration number: NTR6584 Date of registration: 30 June 2017 Implications for Cancer Survivors: Patients’ emotional functioning might improve from routine discussions regarding goals of future care. Therefore, integration of ACP into palliative might be promising

    Comment on the article by Trolese T et al

    No full text
    The recent introduction of quadripolar leads for cardiac resynchronization therapy raises the question which pacing vector is most beneficial to response and which parameter gives insight into the optimal vector. The study conducted by Trolese et al. is therefore of important value and unique in its kind.1 The found correlation between maximal difference of the QRS-width (ΔQRS) and acute haemodynamic response (AHR) (ΔLV dP/dtmax) is an important finding to aid vector selection. However, their results give rise to questions

    Quadripolar Leads in Cardiac Resynchronization Therapy

    No full text
    Despite the benefit of cardiac resynchronization therapy (CRT) in patients with heart failure and conduction delay, a considerable number of patients do not respond substantially. Left ventricular lead position is an important factor in response, restricted by the patient's specific anatomy and local pathophysiology. Quadripolar leads could enhance response to CRT, offering 4 pacing locations along the distal end of the lead. Several quadripolar leads are available, all with different shapes and electrode spacing. Electrodes can be positioned in an ideal pacing location, determined by delayed mechanical or electrical activation, and away from phrenic nerve stimulation, high pacing thresholds, and fibrosis. Implantation is safe, with comparable or even lower complication rates compared with standard bipolar leads. Studies on biventricular pacing with quadripolar leads show apparent variations in acute hemodynamic response between pacing configurations, implying a patient-specific response. Pacing with an optimal pacing vector of a quadripolar lead benefits acute hemodynamic response. Multipoint pacing, pacing the left ventricle with 2 of 4 electrodes, could further enhance response. However, larger trials are needed to confirm these results, and results on long-term outcome of CRT with quadripolar leads and the benefit of multipoint pacing are warranted. We conclude that quadripolar leads are an important improvement in the treatment of heart failure patients with CRT

    Comparison of septal strain patterns in dyssynchronous heart failure between speckle tracking echocardiography vendor systems

    No full text
    AIM: To analyze inter-vendor differences of speckle tracking echocardiography (STE) in imaging cardiac deformation in patients with dyssynchronous heart failure. METHODS AND RESULTS: Eleven patients (all with LBBB, median age 60.7 years, 9 males) with implanted cardiac resynchronization therapy devices were prospectively included. Ultrasound systems of two vendors (i.e. General Electric and Philips) were used to record images in the apical four chamber view. Regional longitudinal strain patterns were analyzed with vendor specific software in the basal, mid and apical septal segments. Systolic strain (SS), time to peak strain (TTP) and septal rebound stretch (SRS) were determined during four pacing settings, resulting in 44 unique strain patterns per segment (total 132 patterns). Cross correlation was used to analyze the comparability of the shape of 132 normalized strain patterns. Correlation of strain patterns of the two systems was high (R(2) median: 0.68, interquartile range: 0.53-0.82). Accordingly, strain patterns of intrinsic rhythm were recognized equally using both systems, when divided into three types. GE based SS (18.9 ± 4.7%) was significantly higher than SS determined by the Philips system (13.4 ± 4.3%). TTP was slightly but non-significantly lower in GE (384 ± 77 ms) compared to Philips (404 ± 83 ms) derived strain signals. Correlation of SRS between the systems was poor, due to minor differences in the strain signal and timing of aortic valve closure. CONCLUSIONS: The two systems provide similar shape of strain patterns. However, important differences are found in the amplitude, timing of systole and SRS. Until STE is standardized, clinical decision making should be restricted to pattern analysis
    corecore