15 research outputs found

    Loss of response to anti-TNF alpha agents depends on treatment duration in patients with inflammatory bowel disease

    Get PDF
    Background: Inflammatory bowel disease (IBD) is often managed with anti-tumour necrosis factor-α therapy (anti-TNFα), but treatment efficacy is compromised by high annual rates of loss of response (13%-21% per patient-year). Aims: To assess whether the incidence of loss of response decreases with longer treatment duration. Methods: This was a multicentre, retrospective cohort study of patients with ulcerative colitis (UC) or Crohn's disease (CD) who received anti-TNFα for at least 4 months between 2011 and 2019. We studied the incidence of loss of response as a function of treatment duration, employing parametric survival modelling. Predictors of loss of response were identified by Cox regression analysis. Secondary outcomes included overall anti-TNFα discontinuation and dose escalation. Results: We included 844 anti-TNFα treatment episodes in 708 individuals. Loss of response occurred in 211 (25.0%) episodes, with anti-drug antibodies detected in 66 (31.3%). During the first year, the incidence of loss of response was three-fold higher than after four years of treatment (17.2% vs 4.8% per patient-year, P < 0.001). The incidence of anti-TNFα discontinuation (28.6% vs 14.0% per patient-year, P < 0.001) and dose escalations (38.0% vs 6.8% per patient-year, P < 0.001) also decreased significantly from the first year to after four years, respectively. Predictors of loss of response included UC (vs CD, adjusted hazard ratio [aHR] 1.53, 95% CI 1.10-2.15) and, among patients with CD, stricturing or penetrating disease (aHR 1.68, 95% CI 1.15-2.46) and male sex (aHR 0.55, 95% CI 0.38-0.78). Immunomodulators were protective against loss of response with anti-drug antibodies (aHR 0.42, 95% CI 0.24-0.74). Conclusions: Patients with sustained benefit to anti-TNFα after 2 years are at low risk of subsequent loss of response

    A fully covered self-expandable metal stent with antimigration features for benign biliary strictures: a prospective, multicenter cohort study

    No full text
    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel FCSEMS with antimigration features. DESIGN: Prospective cohort study. SETTING: Five hospitals in the Netherlands and Belgium. PATIENTS: Consecutive patients with BBS. INTERVENTION: FCSEMS placement for 3 months. MAIN OUTCOME MEASUREMENTS: Initial and long term clinical success, stent migration rate and safety. RESULTS: Thirty-eight patients (24 men; mean age, 53 ± 16 years) were included. Stent placement was technically successful in 37 patients (97%). Two patients died of an unrelated cause before stent removal, and no data on these patients were available on stricture resolution. Initial clinical success was achieved in 28 of 35 patients (80%). During follow-up after stent removal, a symptomatic recurrent stricture developed in 6 of 28 patients (21%). Overall, the long-term clinical success rate was 63% (22 of 35 patients). Stent migration occurred in 11 of 35 patients (31%), including 5 symptomatic (14%) and 6 asymptomatic (17%) migrations. In total, 11 serious adverse events occurred in 10 patients (29%), with cholangitis (n = 5) being most common. LIMITATIONS: Nonrandomized study design. CONCLUSIONS: Good initial clinical success was achieved after placement of this novel FCSEMS, but stricture recurrence was in the upper range compared with other FCSEMSs. The antimigration design could not prevent migration in a significant number of patients with a persisting stricture.status: publishe

    A fully covered self-expandable metal stent with antimigration features for benign biliary strictures : a prospective, multicenter cohort study

    No full text
    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel FCSEMS with antimigration features. DESIGN: Prospective cohort study. SETTING: Five hospitals in the Netherlands and Belgium. PATIENTS: Consecutive patients with BBS. INTERVENTION: FCSEMS placement for 3 months. MAIN OUTCOME MEASUREMENTS: Initial and long term clinical success, stent migration rate and safety. RESULTS: Thirty-eight patients (24 men; mean age, 53 ± 16 years) were included. Stent placement was technically successful in 37 patients (97%). Two patients died of an unrelated cause before stent removal, and no data on these patients were available on stricture resolution. Initial clinical success was achieved in 28 of 35 patients (80%). During follow-up after stent removal, a symptomatic recurrent stricture developed in 6 of 28 patients (21%). Overall, the long-term clinical success rate was 63% (22 of 35 patients). Stent migration occurred in 11 of 35 patients (31%), including 5 symptomatic (14%) and 6 asymptomatic (17%) migrations. In total, 11 serious adverse events occurred in 10 patients (29%), with cholangitis (n = 5) being most common. LIMITATIONS: Nonrandomized study design. CONCLUSIONS: Good initial clinical success was achieved after placement of this novel FCSEMS, but stricture recurrence was in the upper range compared with other FCSEMSs. The antimigration design could not prevent migration in a significant number of patients with a persisting stricture

    Validation and update of a prediction model for risk of relapse after cessation of anti-TNF treatment in Crohn's disease

    Get PDF
    BACKGROUND: Anti-tumor necrosis factor (TNF) therapy is effective for the treatment of Crohn's disease. Cessation may be considered in patients with a low risk of relapse. We aimed to externally validate and update our previously developed prediction model to estimate the risk of relapse after cessation of anti-TNF therapy. METHODS: We performed a retrospective cohort study in 17 Dutch hospitals. Crohn's disease patients in clinical, biochemical or endoscopic remission were included after anti-TNF cessation. Primary outcome was a relapse necessitating treatment. Discrimination and calibration of the previously developed model were assessed. After external validation, the model was updated. The performance of the updated prediction model was assessed in internal-external validation and by using decision curve analysis. RESULTS: 486 patients were included with a median follow-up of 1.7 years. Relapse rates were 35 and 54% after 1 and 2 years. At external validation, the discriminative ability of the prediction model was equal to that found at the development of the model [c-statistic 0.58 (95% confidence interval (CI) 0.54-0.62)], though the model was not well-calibrated on our cohort [calibration slope: 0.52 (0.28-0.76)]. After an update, a c-statistic of 0.60 (0.58-0.63) and calibration slope of 0.89 (0.69-1.09) were reported in internal-external validation. CONCLUSION: Our previously developed and updated prediction model for the risk of relapse after cessation of anti-TNF in Crohn's disease shows reasonable performance. The use of the model may support clinical decision-making to optimize patient selection in whom anti-TNF can be withdrawn. Clinical validation is ongoing in a prospective randomized trial

    Cost Efficacy of Metal Stents for Palliation of Extrahepatic Bile Duct Obstruction in a Randomized Controlled Trial

    No full text
    BACKGROUND & AIMS: Endoscopic stents are placed for palliation of extrahepatic bile duct obstruction. Although self-expandable metal stents (SEMS) remain patent longer than plastic stents, they are more expensive. We aimed to evaluate which type of stent (plastic, uncovered SEMS [uSEMS], or partially covered SEMS [pcSEMS]) is the most effective and we assessed costs. METHODS: We performed a multicenter randomized trial in 219 patients at 18 hospitals in The Netherlands from February 2008 through February 2013. Patients were assigned randomly for placement of a plastic stent (n = 73), uSEMS (n = 75), or pcSEMS (n = 71) during endoscopic retrograde cholangiopancreatography. Patients were followed up for up to 1 year. Researchers were not blinded to groups. The main study end points included functional stent time and costs. RESULTS: The mean functional stent times were 172 days for plastic stents, 288 days for uSEMS, and 299 days for pcSEMS (P < .005 for uSEMS and pcSEMS vs plastic). The initial placement of plastic stents (€1042 or 1106)costsignificantlylessthanplacementofSEMS(€1973or1106) cost significantly less than placement of SEMS (€1973 or 2094) (P = .001). However, the total cost per patient at the end of the follow-up period did not differ significantly between plastic stents (€7320 or 7770)andSEMS(€6932or7770) and SEMS (€6932 or 7356) (P = .61). Furthermore, in patients with short survival times (≤3 mo) or metastatic disease, the total cost per patient did not differ between plastic stents and SEMS. No differences in costs were found between pcSEMS and uSEMS. CONCLUSIONS: Although placement of SEMS (uncovered or partially covered) for palliation of extrahepatic bile duct obstruction initially is more expensive than placement of plastic stents, SEMS have longer functional time. The total costs after 1 year do not differ significantly with stent type. Dutch Clinical Trial Registration no: NTR1361.publisher: Elsevier articletitle: Cost Efficacy of Metal Stents for Palliation of Extrahepatic Bile Duct Obstruction in a Randomized Controlled Trial journaltitle: Gastroenterology articlelink: http://dx.doi.org/10.1053/j.gastro.2015.03.012 content_type: article copyright: Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.status: publishe

    Cost Efficacy of Metal Stents for Palliation of Extrahepatic Bile Duct Obstruction in a Randomized Controlled Trial

    No full text
    BACKGROUND & AIMS: Endoscopic stents are placed for palliation of extrahepatic bile duct obstruction. Although self-expandable metal stents (SEMS) remain patent longer than plastic stents, they are more expensive. We aimed to evaluate which type of stent (plastic, uncovered SEMS [uSEMS], or partially covered SEMS [pcSEMS]) is the most effective and we assessed costs. METHODS: We performed a multicenter randomized trial in 219 patients at 18 hospitals in The Netherlands from February 2008 through February 2013. Patients were assigned randomly for placement of a plastic stent (n = 73), uSEMS (n = 75), or pcSEMS (n = 71) during endoscopic retrograde cholangiopancreatography. Patients were followed up for up to 1 year. Researchers were not blinded to groups. The main study end points included functional stent time and costs. RESULTS: The mean functional stent times were 172 days for plastic stents, 288 days for uSEMS, and 299 days for pcSEMS (P < .005 for uSEMS and pcSEMS vs plastic). The initial placement of plastic stents (€1042 or 1106)costsignificantlylessthanplacementofSEMS(€1973or1106) cost significantly less than placement of SEMS (€1973 or 2094) (P = .001). However, the total cost per patient at the end of the follow-up period did not differ significantly between plastic stents (€7320 or 7770)andSEMS(€6932or7770) and SEMS (€6932 or 7356) (P = .61). Furthermore, in patients with short survival times (≤3 mo) or metastatic disease, the total cost per patient did not differ between plastic stents and SEMS. No differences in costs were found between pcSEMS and uSEMS. CONCLUSIONS: Although placement of SEMS (uncovered or partially covered) for palliation of extrahepatic bile duct obstruction initially is more expensive than placement of plastic stents, SEMS have longer functional time. The total costs after 1 year do not differ significantly with stent type. Dutch Clinical Trial Registration no: NTR1361

    Higher quality of life after metal stent placement compared with plastic stent placement for malignant extrahepatic bile duct obstruction: a randomized controlled trial

    No full text
    OBJECTIVE: For palliation of extrahepatic bile duct obstruction, self-expandable metal stents (SEMS) are superior to plastic stents in terms of stent patency and occurrence of stent dysfunction. We assessed health-related quality of life (HRQoL) after stent placement to investigate whether this also results in a difference in HRQoL between patients treated with a plastic stent or SEMS. PATIENTS AND METHODS: This randomized multicenter trial included 219 patients who were randomized to receive plastic stent (n=73) or SEMS [uncovered (n=75) and covered (n=71); n=146] placement. HRQoL was assessed with two general questionnaires (EQ-5D-3L and QLQ-C30) and one disease-specific questionnaire (PAN-26). Scores were analyzed using linear mixed model regression and included all patients with baseline and at least one follow-up measurement. RESULTS: HRQoL data were available in 140 of 219 patients (64%); 71 patients (32%) declined participation and in eight patients (4%) only baseline questionnaires were available. On the QLQ-C30, the interaction between follow-up time and type of stent was significantly different on two of five functional scales [physical functioning (P=0.004) and emotional functioning (P=0.01)] in favor of patients with a SEMS. In addition, patients with SEMS reported significantly less frequent symptoms of fatigue (P=0.01), loss of appetite (P=0.02), and nausea and vomiting (0.04) over time. The EQ-VAS score decreased with time in both treatment groups, indicating a statistically significant decrease in HRQoL over time. CONCLUSION: In patients with inoperable malignant extrahepatic bile duct obstruction, SEMS placement results in better scores for general and disease-specific HRQoL over time compared with plastic stent placement.status: publishe

    Higher quality of life after metal stent placement compared with plastic stent placement for malignant extrahepatic bile duct obstruction:A randomized controlled trial

    Get PDF
    Objective For palliation of extrahepatic bile duct obstruction, self-expandable metal stents (SEMS) are superior to plastic stents in terms of stent patency and occurrence of stent dysfunction. We assessed health-related quality of life (HRQoL) after stent placement to investigate whether this also results in a difference in HRQoL between patients treated with a plastic stent or SEMS. Patients and methods This randomized multicenter trial included 219 patients who were randomized to receive plastic stent (n = 73) or SEMS [uncovered (n = 75) and covered (n = 71); n = 146] placement. HRQoL was assessed with two general questionnaires (EQ-5D-3L and QLQ-C30) and one disease-specific questionnaire (PAN-26). Scores were analyzed using linear mixed model regression and included all patients with baseline and at least one follow-up measurement. Results HRQoL data were available in 140 of 219 patients (64%); 71 patients (32%) declined participation and in eight patients (4%) only baseline questionnaires were available. On the QLQ-C30, the interaction between follow-up time and type of stent was significantly different on two of five functional scales [physical functioning (P = 0.004) and emotional functioning (P = 0.01)] in favor of patients with a SEMS. In addition, patients with SEMS reported significantly less frequent symptoms of fatigue (P = 0.01), loss of appetite (P = 0.02), and nausea and vomiting (0.04) over time. The EQ-VAS score decreased with time in both treatment groups, indicating a statistically significant decrease in HRQoL over time. Conclusion In patients with inoperable malignant extrahepatic bile duct obstruction, SEMS placement results in better scores for general and disease-specific HRQoL over time compared with plastic stent placement. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved
    corecore