20 research outputs found

    Prognostication using SpO(2)/FiO(2) in invasively ventilated ICU patients with ARDS due to COVID-19-Insights from the PRoVENT-COVID study

    Get PDF
    Background: The SpO(2)/FiO(2) is a useful oxygenation parameter with prognostic capacity in patients with ARDS. We investigated the prognostic capacity of SpO(2)/FiO(2) for mortality in patients with ARDS due to COVID-19. Methods: This was a post-hoc analysis of a national multicenter cohort study in invasively ventilated patients with ARDS due to COVID-19. The primary endpoint was 28-day mortality. Results: In 869 invasively ventilated patients, 28-day mortality was 30.1%. The SpO(2)/FiO(2) on day 1 had no prognostic value. The SpO(2)/FiO(2) on day 2 and day 3 had prognostic capacity for death, with the best cut-offs being 179 and 199, respectively. Both SpO(2)/FiO(2) on day 2 (OR, 0.66 [95%-CI 0.46-0.96]) and on day 3 (OR, 0.70 [95%-CI 0.51-0.96]) were associated with 28-day mortality in a model corrected for age, pH, lactate levels and kidney dysfunction (AUROC 0.78 [0.76-0.79]). The measured PaO2/FiO(2) and the PaO2/FiO(2) calculated from SpO(2)/FiO(2) were strongly correlated (Spearman's r = 0.79). Conclusions: In this cohort of patients with ARDS due to COVID-19, the SpO(2)/FiO(2) on day 2 and day 3 are independently associated with and have prognostic capacity for 28-day mortality. The SpO(2)/FiO(2) is a useful metric for risk stratification in invasively ventilated COVID-19 patients. (C) 2021 The Authors. Published by Elsevier Inc

    De ontwikkeling van het cursorisch fellowonderwijs intensive care geneeskunde in het vrije universiteit medisch centrum: Ervaringen van het eerste curriculum

    No full text
    In the Netherlands, the national training programme of Intensive Care Medicine is organized by the Gemeenschappelijke Intensivisten Commissie (GIC). Participation in the examination to obtain the European Diploma in Intensive Care (EDIC) organized by the European Society of Intensive Care Medicine (ESICM) is compulsory according to the regulations of the GIC. The GIC curriculum committee is responsible for the national theoretical training programme. The hospitals have organized, each in their own way, local courses of theoritical fellow education. In this article, we describe our experience with the first curriculum in the Vrije Universiteit Medisch Centrum. We discuss the philosophy, organization and logistics of the chosen educational model, report the evaluation of the first curriculum, and formulate suggestions for improvement

    United we stand, divided we fall: the failure of an accounting information system in a major radiology provider

    No full text
    This article explores the way in which a major Australian radiology organization implemented a complex accounting information system and how workers in the 72 radiology practises that had to use it resisted the change. The study reports on the issues that led to the circumvention of the system by individuals and, after only three years, complete withdrawal of the accounting information system by the parent organization. This article has implications for firms in the health care and other sectors considering implementing new accounting information systems. Organizations need to incorporate change management techniques and provide open communication to all stakeholders to minimize disruption and potential problems

    Validation of the urine column measurement as an estimation of the intra-abdominal pressure.

    Get PDF
    Item does not contain fulltextOBJECTIVE: To evaluate the efficacy of the urine column (UC) measurement compared to the intra-vesicular pressure (IVP) measurement as an estimation of intra-abdominal pressure (IAP) in patients with IAP up to 30 mmHg. METHODS: Fifteen patients undergoing a laparoscopic cholecystectomy were studied. All patients were catheterized. IVP measurements were performed using a pressure transducer connected to the culture aspiration port. UC measurements were done by holding up the tubing against a measuring rod. The symphysis pubis was used as the zero-reference. IAP was raised from 0 to 30 mmHg using increments of 5 mmHg, during which first the IVP and then UC measurement series were recorded end-expiratory. Fifty and 100 ml of saline were used as a priming volume. RESULTS: The IVP and UC measurements showed a significant correlation with IAP. Comparing IVP and UC showed a correlation of 0.91 (p < 0.001) for 50 ml and 0.87 (p < 0.001) for 100 ml of saline as a priming volume. Using 50 ml of saline, UC was 0.68 mmHg higher than IVP (95% CI -7.21 to +5.85 mmHg). For 100 ml of saline, UC was 1.23 mmHg lower than IVP (95% CI -7.41 to +9.87 mmHg). CONCLUSION: UC measurement shows significant correlation to IVP measurement as an estimation of the IAP. Further study needs to be done to conclude whether UC measurement is a reliable clinical alternative to IVP measurement
    corecore