29 research outputs found

    Improving PMMA resin using graphene oxide for a definitive prosthodontic rehabilitation - A clinical report

    Get PDF
    The use of acrylic resins as a definitive material has shown some advantages comparing to other definitive materials. However, their poor mechanical properties remain a major drawback. In this case report, graphene oxide (GO) was incorporated into polymethyl methacrylate (PMMA) resin for a definitive maxillary rehabilitation, combined with an intraoral digital impression and a three-dimensional facial scan. After 8 months of the placement of the definitive prosthesis, no mechanical, aesthetic, or biologic complications were reported, and the soft tissues showed excellent health and stability. The incorporation of GO in PMMA resins seems to be a suitable option for prosthetic rehabilitation. However, further studies are needed to ensure rigorous scientific support of these techniques and materials

    Biologically oriented preparation technique (BOPT) for implant-supported fixed prostheses

    Get PDF
    A patient of 58 years of age without medical problems came to the clinic due to missing teeth in the upper posterior region and to change the partial fixed prosthesis in the upper anterior area. Proposed treatment: surgical phase of three conical shape tapering implants with prosthetic platform in occlusal direction with mechanize collar tissue level with fixtures to place implant-supported metal-ceramic restorations. In the anterior area, a zirconium oxide fixed partial prosthesis was vertical preparation of the tooth?s. When preparing teeth to receive fixed prostheses, the definition and shape of finish lines has been a subject of endless discussion, modification, and change ever since the beginnings of restorative prosthetic dentistry. The BOPT technique (biologically oriented preparation technique) was first described in the context of tooth-supported restorations but has recently been applied to dental implants with the aim of ensuring healthy peri-implant tissue and creating the possibility of modeling the peri-implant sulcus by modifying prosthetic emergence profiles. Vertical preparation of teeth and abutments without finish line on implants is a technique which was found to be adequate for ensuring the remodeling and stability of peri-implant tissues

    Internacionalización y convergencia de las variaciones en los métodos docentes en Prótesis Estomatológica, iniciados y proyectados a raíz de la pandemia por Covid-19, en las facultades europeas de Odontología durante el último curso de Grado

    Get PDF
    Investigar los cambios (propiciados por la pandemia de Covid-19) en la docencia de prótesis en 5º de Odontología en Europa durante el curso 2020-21. Para ello hemos diseñado y distribuido un cuestionario acerca de la dedicación presencial, telemática y asistencial con pacientes. Estamos iniciando una red de trabajo europea para compartir la retroalimentación de este proyecto y las experiencias de los compañeros que coordinan esta disciplina en otras facultades europeas, para fomentar el proceso de convergencia al EEES en un momento tan crucial como el que estamos viviendo

    Electromyographic study of activity of the masseter and anterior temporalis muscles in patients with temporomandibular joint (TMJ) dysfuction : comparison with the clinical dysfunction index

    Get PDF
    Objectives: A comparison was made between the electromyographic patterns specific to patient with temporomandibular disorders and that of normal healthy patients. Study design: Electromyographic tests were carried out during rest and function of the masseter muscles and anterior temporalis muscles in a homogeneous group consisting of 95 patients for whom such pathology and its different degree of severity had been previously studied by means of a Helkimo Test. The electromyographic exploration results were compared to those of a control group consisting of 31 healthy subjects. Results: There were significant differences among patients with a different degree of clinical dysfunction, as well as between these and the control group. These differences were more important during maximum effort clenching and mastication. During maximum effort clenching, differences in masseteric activity were observed between control group and group III, between groups I and II and between groups I and III. Meanwhile, differences in temporalis activity were significant among all groups except between groups I and II. The multiple comparison analysis demonstrated the existence of significant statistical differences between healthy subjects and patients with severe TMD. However, the linear combination of these electromyographic (EMG) variables led us to elaborate four linear functions that classify all subjects into four well defined groups. Once extreme cases were eliminated, our EMG classification revealed an 80% match with that of the Helkimo Test. We thus conclude that in many cases, classification using electromyographic criteria matches that established by the Helkimo Test

    ‘Role of the modulating factors on the self-perceived OHRQoL of fully dentate subjects and wearers of screw-retained and cement-retained implant-supported FPDs: A cross-sectional study’

    Get PDF
    Objectives: This research aimed to compare the oral health-related quality of life (OHRQoL) between fully dentate subjects and edentulous patients wearing implant-supported fixed partial dentures (i-FPDs). The clinical conditions of both types of restorations were evaluated. Methods: Participants were assigned to: Group-1 (SR, n = 50): screw-retained i-FPD wearers; Group-2 (CR, n = 50): cement-retained i-FPD wearers; and Group-3 (ND, n = 50): dentate subjects with a healthy natural dentition (controls). Patients answered the OHIP-14sp and QoLIP-10 questionnaires. Data related to sociodemographics, prosthesis features, peri implant status, complications, and subjective evaluations, were compiled. Potential modulators of the OHRQoL and the i-FPDs’ clinical conditions were assessed using non-parametric tests (α= 0.05). Results: ND individuals were the least satisfied (OHIP-14sp; p< 0.001). Both prosthodontic groups reported similar levels of wellbeing, excluding the speaking difficulties, which were lower for SR wearers as shown by both scales (p = 0.001). The most discontented patients (OHIP-14sp) were: women (p = 0.022), under 65 years (p = 0.03), without partner (p< 0.001) and having a crown (p = 0.033). The level of education/schooling also affected the OHIP-14sp scores (p< 0.001). Implant mobility and peri implantitis were more frequent among CR wearers (p-values= 0.008 and 0.05, respectively). Conclusions: The OHRQoL of both prosthodontic groups was comparably higher than that of the dentate subjects, who were the most nonconformist. The self-perceived satisfaction was mainly modulated by sociodemographic factors. Clinical significance: Overall, the retention system did not impact the OHRQoL, prosthetic problems, and subjective evaluations of i-FPD wearers. However, the cementation may increase the risk of peri implant diseases

    Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

    Get PDF
    The aim of this in vitro study was to investigate the microgaps at the implant-abutment interface when zirconia (Zr) and CAD/CAM or cast Co-Cr abutments were used. METHODS Sixty-four conical connection implants and their abutments were divided into four groups (Co-Cr (milled, laser-sintered and castable) and Zirconia (milled)). After chewing simulation (300,000 cycles, under 200 N loads at 2 Hz at a 30° angle) and thermocycling (10,000 cycles, 5 to 50 °C, dwelling time 55 s), the implant-abutment microgap was measured 14 times at each of the four anatomical aspects on each specimen by using a scanning electron microscope (SEM). Kruskal-Wallis and pair-wise comparison were used to analyze the data (α = 0.05). RESULTS The SEM analysis revealed smaller microgaps with Co-Cr milled abutments (0.69-8.39 μm) followed by Zr abutments (0.12-6.57 μm), Co-Cr sintered (7.31-25.7 μm) and cast Co-Cr (1.68-85.97 μm). Statistically significant differences were found between milled and cast Co-Cr, milled and laser-sintered Co-Cr, and between Zr and cast and laser-sintered Co-Cr (p < 0.05). CONCLUSIONS The material and the abutment fabrication technique affected the implant-abutment microgap magnitude. The Zr and the milled Co-Cr presented smaller microgaps. Although the CAD/CAM abutments presented the most favorable values, all tested groups had microgaps within a range of 10 to 150 μm

    Differences in self-perceived OHRQoL between fully dentate subjects and edentulous patients depending on their prosthesis type, socio-demographic profile, and clinical features

    Get PDF
    Objectives: This observational cross-sectional study aimed to evaluate and compare the oral health-related quality of life (OHRQoL) and clinical performance between dentate subjects and edentulous patients restored with conventional dentures or implant overdentures. Methods: 85 edentulous patients were grouped as follows: Group-1 (CD): conventional denture wearers (n = 42), and Group-2 (IO): implant-retained overdenture wearers (n = 43). For the OHRQoL comparisons, a control group of subjects with a healthy natural dentition (Group-3, ND; n = 50) was included. Participants completed three validated questionnaires (OHIP-14sp, OHIP-20sp, and QoLIP-10). Socio-demographic data, prosthesis-related factors, clinical condition of the mouth, and patient subjective evaluations, were gathered. Descriptive and non-parametric probes were run (α = 0.05). Results: The ND group was the most unsatisfied (OHIP-14sp; p ≤ 0.001). The OHIP-20sp attributed significantly worse Psychological disability (p = 0.029) and Handicap (p = 0.027) to CD wearers when compared to IO wearers. The CD group showed the significantly highest need for relining (p = 0.041), and the lowest retention (p = 0.011). The OHIP-14sp disclosed a significantly worse OHRQoL for those volunteers who had a job (p = 0.003), a basic education instead of a secondary one (p = 0.022), and no partner (p = 0.006). Conclusions: The overall OHRQoL was comparable for both prosthodontic groups, being modulated by sociodemographic and prosthesis-related features. Nonetheless, CD wearers presented prosthetic complications more frequently. Clinical significance: While dentate subjects were the most critical about their oral condition and its repercussion in their life, implant overdenture wearers tended to observe a better OHRQoL and clinical performance compared to conventional denture wearers

    Influence of orthodontic treatment on temporomandibular disorders: a systematic review

    Get PDF
    Objectives: The aim of this literature systematic review was to evaluate the possible association between malocclusions, orthodontic treatment and development of temporomandibular disorders. Material and Methods: A search was carried out on PubMed-Medline database from January 2000 to August 2013 using the keywords “ orthodontics and temporomandibular disorders ”, “ orthodontics and facial pain ” and “ malocclusion and temporomandibular disorders ”. Human studies included in the study were those assessing signs and symptoms of temporomandibular disorders in relation to orthodontic treatment. Results: The search strategy resulted in 61 articles. After selection according to the inclusion/exclusion criteria 9 articles qualified for the final analysis. The articles which linked orthodontics and development of temporomandibular disorders showed very discrepant results. Some indicated that orthodontic treatment could improve signs and symptoms of temporomandibular disorders, but none of them obtained statistically significant dif ferences. Conclusions: According to the authors examined, there is no evidence for a cause-effect relationship between orthodontic treatment and temporomandibular disorders, or that such treatment might improve or prevent them. More longitudinal studies are needed to verify any possible interrelationshi

    La Odontología española en el año 2006, situación epidemiológica

    No full text
    Introducción Con este trabajo de revisión bibliográfica pretendemos resumir el panorama odontológico a nivel nacional para que pueda ser contrastado con resultados epidemiológicos futuros. Resultados Las medidas preventivas de la población deben intensificarse aunque han mejorado respecto a años anteriores; La patología odontológica española se ha reducido en cuanto a caries y extracciones se refiere; se ha incrementado la edad media de los pacientes y no existen diferencias significativas entre los núcleos de población. Por otro lado, el crecimiento desmesurado del número de odontólogos ha comercializado la profesión, elevando el paro profesional y las denuncias y reduciendo la calidad del servicio. Conclusiones Las medidas deben ir encaminadas al diagnóstico y prevención de la patología. La oferta odontológica no debe estar regulada por el mercado como viene sucediendo
    corecore