455 research outputs found

    Site Visit Frequency Policies for Mobile Family Planning Services

    Get PDF
    Improving access to family planning services is key to achieving many of the United Nations sustainable development goals. To scale up access in remote areas and urban slums, many developing countries deploy mobile family planning teams that visit “outreach sites” several times per year. Visit frequencies have a significant effect on the total number of clients served and hence the impact of the outreach program. Using a large dataset of visits in Madagascar, Uganda and Zimbabwe, our study models the relationship between the number of clients seen during a visit and the time since the last visit and uses this model to analyse the characteristics of optimal frequencies. We use the latter to develop simple frequency policies for practical use, prove bounds on the worst-case optimality gap, and test the impact of the policies with a simulation model. Our main finding is that despite the complexity of the frequency optimisation problem, simple policies yield near-optimal results. This holds even when few data are available and when the relationship between client volume and the time since the last visit is misspecified or substantially biased. The simulation for Uganda shows a potential increase in client numbers of between 7% and 10%, which corresponds to more than 12,000 additional families to whom family planning services could be provided.

    Sentinel lymph node detection in thyroid carcinoma using 68Ga-tilmanocept PET/CT: a proof-of-concept study protocol

    Get PDF
    Sentinel lymph node biopsy (SLNB) is a diagnostic staging procedure. The procedure aims to identify the first draining lymph node(s), which are most likely to contain metastases. SLNB is applied in various cancers, but not currently in thyroid carcinoma. However, treatment strategies are changing, making SLNB clinically relevant. SLNB may lead to more accurate staging, prevent unnecessary treatment and help achieve earlier curation. 68Ga-tilmanocept PET/computed tomography (CT) can better localize sentinel lymph nodes (SLNs) near the primary tumor than planar scintigraphy and single-photon emission computed tomography (SPECT)/CT. This paper describes the rationale and design of a study investigating SLNB using 68Ga-tilmanocept PET/CT and indocyanine-green- 99mTc-nanocolloid in ten differentiated and medullary thyroid carcinoma patients. Localization and number of SLNs, pathology result, optimal scan protocol, surgical time and surgeon's experience are examined. Clinical Trial Registration: 2021-002470-42 (EudraCT)

    Outcomes of Minimally Invasive Thyroid Surgery - A Systematic Review and Meta-Analysis

    Get PDF
    Purpose: Conventional thyroidectomy has been standard of care for surgical thyroid nodules. For cosmetic purposes different minimally invasive and remote-access surgical approaches have been developed. At present, the most used robotic and endoscopic thyroidectomy approaches are minimally invasive video assisted thyroidectomy (MIVAT), bilateral axillo-breast approach endoscopic thyroidectomy (BABA-ET), bilateral axillo-breast approach robotic thyroidectomy (BABA-RT), transoral endoscopic thyroidectomy via vestibular approach (TOETVA), retro-auricular endoscopic thyroidectomy (RA-ET), retro-auricular robotic thyroidectomy (RA-RT), gasless transaxillary endoscopic thyroidectomy (GTET) and robot assisted transaxillary surgery (RATS). The purpose of this systematic review was to evaluate whether minimally invasive techniques are not inferior to conventional thyroidectomy. Methods: A systematic search was conducted in Medline, Embase and Web of Science to identify original articles investigating operating time, length of hospital stay and complication rates regarding recurrent laryngeal nerve injury and hypocalcemia, of the different minimally invasive techniques. Results: Out of 569 identified manuscripts, 98 studies met the inclusion criteria. Most studies were retrospective in nature. The results of the systematic review varied. Thirty-one articles were included in the meta-analysis. Compared to the standard of care, the meta-analysis showed no significant difference in length of hospital stay, except a longer stay after BABA-ET. No significant difference in incidence of recurrent laryngeal nerve injury and hypocalcemia was seen. As expected, operating time was significantly longer for most minimally invasive techniques. Conclusions: This is the first comprehensive systematic review and meta-analysis comparing the eight most commonly used minimally invasive thyroid surgeries individually with standard of care. It can be concluded that minimally invasive techniques do not lead to more complications or longer hospital stay and are, therefore, not inferior to conventional thyroidectomy

    Sentinel lymph node detection in thyroid carcinoma using [ 68Ga]Ga-tilmanocept PET/CT: a proof-of-concept study.

    Get PDF
    PURPOSE: Sentinel lymph node (SLN) biopsy is rarely used for thyroid carcinoma staging. This is due to challenges associated with conventional Tc-99m-labeled tracers, often producing a large hotspot at the injection site, potentially hiding nearby SLNs (shine-through effect). The aim of this study was to demonstrate the feasibility and effectiveness of SLN visualization using the new PET tracer [ 68Ga]Ga-tilmanocept. METHODS: Patients with thyroid carcinoma underwent ultrasound-guided peritumoral injection of [ 68Ga]Ga-tilmanocept and ICG-[ 99mTc]Tc-nanocolloid. [ 68Ga]Ga-tilmanocept PET/CT scans were conducted at 15 min and 60 min post-injection to visualize the SLNs. SLN biopsy was performed using ICG-[ 99mTc]TC-nanocolloid for intraoperative identification. The corresponding lymph node level was resected for reference. RESULTS: Seven differentiated thyroid carcinoma (DTC) and 3 medullary thyroid carcinoma (MTC) patients were included, of which 6 were clinically node-negative. The median number of SLNs detected on [ 68Ga]Ga-tilmanocept PET/CT and resected was 3 (range 1-4) and 3 (range 1-5), respectively. Eight SLNs were found on PET/CT in the central compartment and 19 in the lateral compartment. The SLN procedure detected (micro)metastases in all patients except one. Seventeen of 27 pathologically assessed SLNs were positive, 8 negative, and 2 did not contain lymph node tissue, which led to upstaging in 5 out of 6 clinically node-negative patients. CONCLUSIONS: [ 68Ga]Ga-tilmanocept PET/CT identified SLNs in all patients, mainly in the lateral neck. The SLNs were successfully surgically detected and resected using ICG-[ 99mTc]Tc-nanocolloid. This technique has the potential to improve neck staging, enabling more personalized treatment of thyroid cancer according to the lymph node status. TRIAL REGISTRATION: 2021-002470-42 (EudraCT)

    68Ga-PSMA PET/CT in radioactive iodine-refractory differentiated thyroid cancer and first treatment results with 177Lu-PSMA-617

    Get PDF
    BACKGROUND: Differentiated thyroid carcinoma (DTC) is the most common type of thyroid cancer. Treatment with surgery, radioactive iodine (RAI), and TSH suppression is effective in most patients. Five to 15% of patients become RAI refractory and need alternative therapy; however, treatment options are limited. 68Ga-PSMA PET/CT, originally developed for prostate cancer, is also applicable to other malignancies, including thyroid carcinoma. The uptake of PSMA in thyroid carcinoma gives opportunities for imaging and therapy of RAI-refractory DTC. The aim of this study was to analyze imaging on 68Ga-PSMA PET/CT and evaluate the response to 177Lu-PSMA-617 therapy in patients with RAI-refractory DTC. MATERIALS AND METHODS: Five patients with RAI-refractory DTC underwent 68Ga-PSMA PET/CT to determine their eligibility for 177Lu-PSMA-617 therapy. 68Ga-PSMA PET/CTs were analyzed visually and quantitatively. Response to 177Lu-PSMA-617 therapy was evaluated using imaging and thyroglobulin (Tg) values. RESULTS: Tracer uptake suspicious for distant metastases was depicted in all 68Ga-PSMA PET/CTs. Based on tracer uptake, three patients were eligible for 177Lu-PSMA-617 therapy, of whom two were treated. One patient showed disease progression on imaging 1 month later, while her Tg values gradually increased from 18 to 63 μg/L in the months after treatment. Another patient showed partial, temporary response of lung and liver metastases. Her Tg levels initially decreased from 17 to 9 μg/L. However, 7 months after treatment, there was disease progression on imaging and Tg levels had increased to 14 μg/L. Imaging with 68Ga-PSMA PET/CT could be compared to 18FDG PET/CT in three patients. Two patients showed additional lesions on 68Ga-PSMA PET/CT, and one patient showed concordant imaging. CONCLUSION: 68Ga-PSMA PET/CT appears to have added value in patients with RAI-refractory DTC, as it is able to detect various types of lesions, some of which were not picked up by 18FDG PET/CT. Furthermore, 68Ga-PSMA PET/CT might be used to identify patients eligible for treatment with 177Lu-PSMA-617. One of the two patients who underwent 177Lu-PSMA-617 therapy showed a modest, temporary response. To draw conclusions about the effectiveness of this therapy, more research is needed

    Functional properties of measles virus proteins derived from a subacute sclerosing panencephalitis patient who received repeated remdesivir treatments

    Get PDF
    Subacute sclerosing panencephalitis (SSPE) is a rare but fatal late neurological complication of measles, caused by persistent measles virus (MeV) infection of the central nervous system. There are no drugs approved for the treatment of SSPE. Here, we followed the clinical progression of a 5-year-old SSPE patient after treatment with the nucleoside analog remdesivir, conducted a post-mortem evaluation of the patient’s brain, and characterized the MeV detected in the brain. The quality of life of the patient transiently improved after the first two courses of remdesivir, but a third course had no further clinical effect, and the patient eventually succumbed to his condition. Post-mortem evaluation of the brain displayed histopathological changes including loss of neurons and demyelination paired with abundant presence of MeV RNA-positive cells throughout the brain. Next-generation sequencing of RNA isolated from the brain revealed a complete MeV genome with mutations that are typically detected in SSPE, characterized by a hypermutated M gene. Additional mutations were detected in the polymerase (L) gene, which were not associated with resistance to remdesivir. Functional characterization showed that mutations in the F gene led to a hyperfusogenic phenotype predominantly mediated by N465I. Additionally, recombinant wild-type-based MeV with the SSPE-F gene or the F gene with the N465I mutation was no longer lymphotropic but instead efficiently disseminated in neural cultures. Altogether, this case encourages further investigation of remdesivir as a potential treatment of SSPE and highlights the necessity to functionally understand SSPE-causing MeV.</p

    Functional properties of measles virus proteins derived from a subacute sclerosing panencephalitis patient who received repeated remdesivir treatments

    Get PDF
    Subacute sclerosing panencephalitis (SSPE) is a rare but fatal late neurological complication of measles, caused by persistent measles virus (MeV) infection of the central nervous system. There are no drugs approved for the treatment of SSPE. Here, we followed the clinical progression of a 5-year-old SSPE patient after treatment with the nucleoside analog remdesivir, conducted a post-mortem evaluation of the patient’s brain, and characterized the MeV detected in the brain. The quality of life of the patient transiently improved after the first two courses of remdesivir, but a third course had no further clinical effect, and the patient eventually succumbed to his condition. Post-mortem evaluation of the brain displayed histopathological changes including loss of neurons and demyelination paired with abundant presence of MeV RNA-positive cells throughout the brain. Next-generation sequencing of RNA isolated from the brain revealed a complete MeV genome with mutations that are typically detected in SSPE, characterized by a hypermutated M gene. Additional mutations were detected in the polymerase (L) gene, which were not associated with resistance to remdesivir. Functional characterization showed that mutations in the F gene led to a hyperfusogenic phenotype predominantly mediated by N465I. Additionally, recombinant wild-type-based MeV with the SSPE-F gene or the F gene with the N465I mutation was no longer lymphotropic but instead efficiently disseminated in neural cultures. Altogether, this case encourages further investigation of remdesivir as a potential treatment of SSPE and highlights the necessity to functionally understand SSPE-causing MeV.</p

    Differential limit on the extremely-high-energy cosmic neutrino flux in the presence of astrophysical background from nine years of IceCube data

    Get PDF
    We report a quasi-differential upper limit on the extremely-high-energy (EHE) neutrino flux above 5Ă—1065\times 10^{6} GeV based on an analysis of nine years of IceCube data. The astrophysical neutrino flux measured by IceCube extends to PeV energies, and it is a background flux when searching for an independent signal flux at higher energies, such as the cosmogenic neutrino signal. We have developed a new method to place robust limits on the EHE neutrino flux in the presence of an astrophysical background, whose spectrum has yet to be understood with high precision at PeV energies. A distinct event with a deposited energy above 10610^{6} GeV was found in the new two-year sample, in addition to the one event previously found in the seven-year EHE neutrino search. These two events represent a neutrino flux that is incompatible with predictions for a cosmogenic neutrino flux and are considered to be an astrophysical background in the current study. The obtained limit is the most stringent to date in the energy range between 5Ă—1065 \times 10^{6} and 5Ă—10105 \times 10^{10} GeV. This result constrains neutrino models predicting a three-flavor neutrino flux of $E_\nu^2\phi_{\nu_e+\nu_\mu+\nu_\tau}\simeq2\times 10^{-8}\ {\rm GeV}/{\rm cm}^2\ \sec\ {\rm sr}at at 10^9\ {\rm GeV}$. A significant part of the parameter-space for EHE neutrino production scenarios assuming a proton-dominated composition of ultra-high-energy cosmic rays is excluded.Comment: The version accepted for publication in Physical Review
    • …
    corecore