18 research outputs found

    Higher baseline global leukocyte DNA methylation is associated with MTX non-response in early RA patients

    No full text
    BACKGROUND: Low-dose methotrexate (MTX) is the first-line therapy in early rheumatoid arthritis (eRA). Up to 40% of eRA patients do not benefit from MTX therapy. MTX has been shown to inhibit one-carbon metabolism, which is involved in the donation of methyl groups. In this study, we investigate baseline global DNA methylation and changes in DNA methylation during treatment in relation to clinical non-response after 3 months of MTX treatment. METHODS: Two hundred ninety-four blood samples were collected from the Treatment in the Rotterdam Early Arthritis Cohort (tREACH, ISRCTN26791028), a multicenter, stratified single-blind clinical trial of eRA patients. Global DNA (hydroxy)methylation was quantified using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) and validated with a global DNA LINE-1 methylation technique. MTX response was determined as ΔDAS28. Additionally, patients were stratified into two response groups according to the European League Against Rheumatism (EULAR) response criteria. Associations between global DNA methylation and response were examined using univariate regression models adjusted for baseline DAS28, baseline erythrocyte folate levels, and body mass index (BMI). RESULTS: Higher baseline global DNA methylation was associated with less decrease of DAS28 (β = 0.15, p = 0.013) and with MTX non-response (OR = 0.010, 95% CI = 0.001-0.188). This result was validated in LINE-1 elements (β = 0.22, p = 0.026). Changes in global DNA (hydroxy)methylation were not associated with MTX response over 3 months. CONCLUSIONS: These results show that higher baseline global DNA methylation in treatment naïve eRA patients is associated with decreased clinical response after 3 months of treatment of eRA patients and can be further evaluated as a predictor for MTX therapy non-response. TRIAL REGISTRATION: ISRCTN, ISRCTN26791028 , registered 23 August 2007-retrospectively registered

    Compliance with the guidelines for laboratory monitoring of patients treated with lithium : A retrospective follow-up study among ambulatory patients in the Netherlands

    No full text
    Objectives: Laboratory monitoring of patients using lithium is important to prevent harm and to increase effectiveness. The aim of this study is to determine compliance with the guidelines for laboratory monitoring of patients treated with lithium overall and within subgroups. Methods: Patients having at least one lithium dispensing for 6 months or longer between January 2010 and December 2015 were identified retrospectively using data from the Dutch PHARMO Database Network. Laboratory monitoring was defined as being compliant with the Dutch Multidisciplinary Clinical Guideline Bipolar Disorders when lithium serum levels, creatinine and thyroid-stimulating hormone (TSH) had been measured at least every 6 months during lithium use. Results: Data were analyzed from 1583 patients with a median duration of 7- to 6-months period of lithium use. Results indicated that patients had been monitored over 6-month period for lithium serum levels 65% of the time, for creatinine 73% of the time and for TSH 54% of the time. Just over one seventh (16%) of patients had been monitored in compliance with the guidelines for all three parameters during total follow-up. Especially males, patients aged below 65 years, patients receiving prescriptions solely from general practitioners, prevalent users of lithium, patients without interacting co-medication, and patients without other days with laboratory measurements had been monitored less frequently in compliance with the guidelines. Conclusions: A considerable proportion of patients had not been monitored in accordance with the guidelines. Further research is needed to understand the reasons for noncompliance and to implement strategies with the ultimate goal of optimizing safety and effectiveness for patients treated with lithium

    Compliance with the guidelines for laboratory monitoring of patients treated with lithium: a retrospective follow-up study among ambulatory patients in the Netherlands

    No full text
    OBJECTIVES: Laboratory monitoring of patients using lithium is important to prevent harm and to increase effectiveness. The aim of this study is to determine compliance with the guidelines for laboratory monitoring of patients treated with lithium overall and within subgroups. METHODS: Patients having at least one lithium dispensing for six months or longer between January 2010 and December 2015 were identified retrospectively using data from the Dutch PHARMO Database Network. Laboratory monitoring was defined as being compliant with the Dutch Multidisciplinary Clinical Guideline Bipolar Disorders when lithium serum levels, creatinine and thyroid-stimulating hormone (TSH) had been measured at least every six months during lithium use. RESULTS: Data were analyzed from 1,583 patients with a median duration of seven six-month periods of lithium use. Results indicated that patients had been monitored over six-month periods for lithium serum levels 65% of the time, for creatinine 73% of the time and for TSH 54% of the time. Just over one seventh (16%) of patients had been monitored in compliance with the guidelines for all three parameters during total follow-up. Especially males, patients aged below 65 years, patients receiving prescriptions solely from general practitioners, prevalent users of lithium, patients without interacting co-medication, and patients without other days with laboratory measurements had been monitored less frequently in compliance with the guidelines. CONCLUSION: A considerable proportion of patients had not been monitored in accordance with the guidelines. Further research is needed to understand the reasons for noncompliance and to implement strategies with the ultimate goal of optimizing safety and effectiveness for patients treated with lithium. This article is protected by copyright. All rights reserved

    Prediction of Methotrexate Intolerance in Juvenile Idiopathic Arthritis : a prospective, observational cohort study

    Get PDF
    Background: Methotrexate (MTX) is an effective and safe drug in the treatment of juvenile idiopathic arthritis (JIA). Despite its safety, MTX-related gastrointestinal adverse effects before and after MTX administration, termed MTX intolerance, occur frequently, leading to non-compliance and potentially premature MTX termination. The aim of this study was to construct a risk model to predict MTX intolerance. Methods: In a prospective JIA cohort, clinical variables and single nucleotide polymorphisms were determined at MTX start. The Methotrexate Intolerance Severity Score was employed to measure MTX intolerance in the first year of treatment. MTX intolerance was most prevalent at 6 or 12 months after MTX start, which was defined as the outcome for the prediction model. The model was developed in 152 patients using multivariable logistic regression analysis and subsequently internally validated using bootstrapping. Results: The prediction model included the following predictors: JIA category, antinuclear antibody, parent/patient assessment of pain, Juvenile Arthritis Disease Activity Score-27, thrombocytes, alanine aminotransferase and creatinine. The model classified 77.5% of patients correctly, and 66.7% of patients after internal validation by bootstrapping. The lowest predicted risk of MTX intolerance was 18.9% and the highest predicted risk was 85.9%. The prediction model was transformed into a risk score (range 0-17). At a cut-off of >= 6, sensitivity was 82.0%, specificity 56.1%, positive predictive value was 58.7% and negative predictive value 80.4%. Conclusions: This clinical prediction model showed moderate predictive power to detect MTX intolerance. To develop into a clinically usable tool, it should be validated in an independent cohort and updated with new predictors. Such an easy-to-use tool could then assist clinicians in identifying patients at risk to develop MTX intolerance, and in turn to monitor them closely and intervene timely in order to prevent the development of MTX intolerance

    Diagnostic work-up of urinary tract infections in pregnancy: study protocol of a prospective cohort study.

    No full text
    INTRODUCTION: Symptoms of urinary tract infections in pregnant women are often less specific, in contrast to non-pregnant women where typical clinical symptoms of a urinary tract infection are sufficient to diagnose urinary tract infections. Moreover, symptoms of a urinary tract infection can mimic pregnancy-related symptoms, or symptoms of a threatened preterm birth, such as contractions. In order to diagnose or rule out a urinary tract infection, additional diagnostic testing is required.The diagnostic accuracy of urine dipstick analysis and urine sediment in the diagnosis of urinary tract infections in pregnant women has not been ascertained nor validated. METHODS AND ANALYSIS: In this single-centre prospective cohort study, pregnant women (≥16 years old) with a suspected urinary tract infection will be included. The women will be asked to complete a short questionnaire regarding complaints, risk factors for urinary tract infections and baseline characteristics. Their urine will be tested with a urine dipstick, urine sediment and urine culture. The different sensitivities and specificities per test will be assessed. Our aim is to evaluate and compare the diagnostic accuracy of urine dipstick analysis and urine sediment in comparison with urine culture (reference test) in pregnant women. In addition, we will compare these tests to a predefined 'true urinary tract infection', to distinguish between a urinary tract infection and asymptomatic bacteriuria. ETHICS AND DISSEMINATION: Approval was requested from the Medical Ethics Review Committee of the Academic Medical Centre; an official approval of this study by the committee was not required. The outcomes of this study will be published in a peer-reviewed journal

    Screening for metabolic vitamin B-12 deficiency by holotranscobalamin in patients suspected of vitamin B-12 deficiency:a multicentre study

    No full text
    Background: Vitamin B-12 deficiency occurs frequently, especially among the elderly. However, screening for vitamin B-12 deficiency is hampered by poor sensitivity of the existing total vitamin B-12 assay. Methylmalonic acid (MMA) is considered as the most representative indicator of metabolic vitamin B-12 deficiency and is used as such in this study. The aim of this study was to validate the clinical usefulness of holotranscobalamin (holoTC) as an initial screening assay for metabolic vitamin B-12 deficiency in a mixed patient population. Methods: Three hundred and sixty blood samples were collected by five Dutch hospitals. Vitamin B-12 and holoTC in serum were measured (AxSYM; Abbott). MMA in serum was measured by tandem mass spectrometry (LC-MS/MS). Results: Receiver operating curve (ROC) analysis demonstrated a greater area under the curve (AUC) for holoTC than for vitamin B-12 in detecting vitamin B-12 deficiency characterized by three predefined cut-off levels of MMA. A cut-off value of 32 pmol/L of holoTC resulted in the highest sensitivity (83%) with acceptable specificity (60%) in detecting MMA concentrations above 0.45 mu mol/L. The combination of vitamin B-12 and holoTC did not improve diagnostic accuracy at this cut-off level. Conclusions: HoloTC has a better diagnostic accuracy than vitamin B-12 and can replace the existing vitamin B-12 assay as a primary screening test in patients suspected of vitamin B-12 deficiency. Critical evaluation of cut-off values of holoTC indicated that a cut-off value of 32 pmol/L can be considered in screening for metabolic vitamin B-12 deficiency (defined by MMA > 0.45 mu mol/L) in a mixed patient population

    Development and validation of a prognostic multivariable model to predict insufficient clinical response to methotrexate in rheumatoid arthritis.

    No full text
    ObjectiveThe objective was to predict insufficient response to 3 months methotrexate (MTX) in DMARD naĂŻve rheumatoid arthritis patients.MethodsA Multivariable logistic regression model of rheumatoid arthritis patients starting MTX was developed in a derivation cohort with 285 patients starting MTX in a clinical multicentre, stratified single-blinded trial, performed in seven secondary care clinics and a tertiary care clinic. The model was validated in a validation cohort with 102 patients starting MTX at a tertiary care clinic. Outcome was insufficient response (disease activity score (DAS)28 >3.2) after 3 months of MTX treatment. Clinical characteristics, lifestyle variables, genetic and metabolic biomarkers were determined at baseline in both cohorts. These variables were dichotomized and used to construct a multivariable prediction model with backward logistic regression analysis.ResultsThe prediction model for insufficient response in the derivation cohort, included: DAS28>5.1, Health Assessment Questionnaire>0.6, current smoking, BMI>25 kg/m2, ABCB1 rs1045642 genotype, ABCC3 rs4793665 genotype, and erythrocyte-folateConclusionsA prognostics prediction model for insufficient response to MTX in 2 prospective RA cohorts by combining genetic, metabolic, clinical and lifestyle variables was developed and validated. This model satisfactorily identified RA patients with high risk of insufficient response to MTX

    Complex machine-learning algorithms and multivariable logistic regression on par in the prediction of insufficient clinical response to methotrexate in rheumatoid arthritis

    No full text
    The goals of this study were to examine whether machine-learning algorithms outper-form multivariable logistic regression in the prediction of insufficient response to methotrexate (MTX); secondly, to examine which features are essential for correct prediction; and finally, to in-vestigate whether the best performing model specifically identifies insufficient responders to MTX (combination) therapy. The prediction of insufficient response (3-month Disease Activity Score 28-Erythrocyte-sedimentation rate (DAS28-ESR) > 3.2) was assessed using logistic regression, least absolute shrinkage and selection operator (LASSO), random forest, and extreme gradient boosting (XGBoost). The baseline features of 355 rheumatoid arthritis (RA) patients from the “treatment in the Rotterdam Early Arthritis CoHort” (tREACH) and the U-Act-Early trial were combined for analyses. The model performances were compared using area under the curve (AUC) of receiver operating characteristic (ROC) curves, 95% confidence intervals (95% CI), and sensitivity and specificity. Fi-nally, the best performing model following feature selection was tested on 101 RA patients starting tocilizumab (TCZ)-monotherapy. Logistic regression (AUC = 0.77 95% CI: 0.68–0.86) performed as well as LASSO (AUC = 0.76, 95% CI: 0.67–0.85), random forest (AUC = 0.71, 95% CI: 0.61 = 0.81), and XGBoost (AUC = 0.70, 95% CI: 0.61–0.81), yet logistic regression reached the highest sensitivity (81%). The most important features were baseline DAS28 (components). For all algorithms, models with six features performed similarly to those with 16. When applied to the TCZ-monotherapy group, logistic regression’s sensitivity significantly dropped from 83% to 69% (p = 0.03). In the current dataset, logistic regression performed equally well compared to machine-learning algorithms in the prediction of insufficient response to MTX. Models could be reduced to six features, which are more conducive for clinical implementation. Interestingly, the prediction model was specific to MTX (combination) therapy response

    Compliance with the guidelines for laboratory monitoring of patients treated with lithium : A retrospective follow-up study among ambulatory patients in the Netherlands

    No full text
    Objectives: Laboratory monitoring of patients using lithium is important to prevent harm and to increase effectiveness. The aim of this study is to determine compliance with the guidelines for laboratory monitoring of patients treated with lithium overall and within subgroups. Methods: Patients having at least one lithium dispensing for 6 months or longer between January 2010 and December 2015 were identified retrospectively using data from the Dutch PHARMO Database Network. Laboratory monitoring was defined as being compliant with the Dutch Multidisciplinary Clinical Guideline Bipolar Disorders when lithium serum levels, creatinine and thyroid-stimulating hormone (TSH) had been measured at least every 6 months during lithium use. Results: Data were analyzed from 1583 patients with a median duration of 7- to 6-months period of lithium use. Results indicated that patients had been monitored over 6-month period for lithium serum levels 65% of the time, for creatinine 73% of the time and for TSH 54% of the time. Just over one seventh (16%) of patients had been monitored in compliance with the guidelines for all three parameters during total follow-up. Especially males, patients aged below 65 years, patients receiving prescriptions solely from general practitioners, prevalent users of lithium, patients without interacting co-medication, and patients without other days with laboratory measurements had been monitored less frequently in compliance with the guidelines. Conclusions: A considerable proportion of patients had not been monitored in accordance with the guidelines. Further research is needed to understand the reasons for noncompliance and to implement strategies with the ultimate goal of optimizing safety and effectiveness for patients treated with lithium

    Validation of a Prognostic Multivariable Prediction Model for Insufficient Clinical Response to Methotrexate in Early Rheumatoid Arthritis and Its Clinical Application in Evidencio

    No full text
    Introduction: Methotrexate (MTX) constitutes the first-line therapy in rheumatoid arthritis (RA), yet approximately 30% of the patients do not benefit from MTX. Recently, we reported a prognostic multivariable prediction model for insufficient clinical response to MTX at 3 months of treatment in the treatment in the Rotterdam Early Arthritis Cohort (tREACH), including baseline predictors: Disease activity score 28 (DAS28), Health Assessment Questionnaire (HAQ), erythrocyte folate, single-nucleotide polymorphisms (SNPs; ABCB1, ABCC3), smoking, and BMI. The purpose of the current study was (1) to externally validate the model and (2) to enhance the model’s clinical applicability. Methods: Erythrocyte folate and SNPs were assessed in 91 early disease-modifying antirheumatic drug (DMARD)-naïve RA patients starting MTX in the external validation cohort (U-Act-Early). Insufficient response (DAS28 > 3.2) was determined after 3 months and non-response after 6 months of therapy. The previously developed prediction model was considered successfully validated in the U-Act-Early (validation cohort) if the area under the curve (AUC) of the receiver operating characteristic (ROC) was not significantly lower than in the tREACH (derivation cohort). Results: The AUCs in U-Act-Early at three and 6 months were 0.75 (95% CI 0.64–0.85) and 0.71 (95% CI 0.60–0.82) respectively, similar to the tREACH. Baseline DAS28 > 5.1 and HAQ > 0.6 were the strongest predictors. The model was simplified by excluding the SNPs, while still classifying 73% correctly. Furthermore, interaction terms between BMI and HAQ and BMI and erythrocyte folate significantly improved the model increasing correct classification to 75%. Results were successfully implemented in Evidencio online platform assisting clinicians in shared decision-making to intensify treatment when appropriate. Conclusions: We successfully externally validated our recently reported prediction model for MTX non-response and enhanced its clinical application thus enabling its evaluation in a clinical trial. Trial Registration: The U-Act-Early is registered at ClinicalTrials.gov. number: NCT01034137. tREACH is registered retrospectively at ISRCTN registry, number: ISRCTN26791028 at 23 August 2007
    corecore