33 research outputs found

    Sensitivity Analysis of Internal Mat Environment during Hot-Pressing

    Get PDF
    The effect of several hot-pressing parameters on the internal mat environment was investigated by using a hot-pressing simulation model. The results were compared to experimental data from laboratory-produced flakeboard. The pressing parameters included initial mat moisture content, final panel density, press platen temperature, and press closing time. The variation of temperature and total gas pressure during the press cycle at six points in the vertical mid-plane of a single layer, random mat structure was predicted with the heat and mass transfer model using the different pressing conditions. Twenty-four boards were manufactured according to the same specifications, and the temperature and internal gas pressure were measured with thermocouples and gas pressure probes at the same six locations. The model consistently predicted the major trends during the hot-pressing operation.The hot-pressing simulation model used in this study was developed based on fundamental engineering principles. The material physical and transport properties were the best available values from the literature or best estimates based on engineering judgment. A sensitivity study assessed the relative importance of the different transport properties during the hot-pressing process. The sensitivity analysis of the model parameters revealed that the thermal conductivity and gas permeability of the mat have the greatest influence on model results. The assessment of these transport properties experimentally, as a function of mat structure, is highly desirable and can considerably improve future model predictions

    Two Phase Description Logic Reasoning for Efficient Information Retrieval

    Get PDF
    Description Logics are used more and more frequently for knowledge representation, creating an increasing demand for efficient automated DL reasoning. However, the existing implementations are inefficient in the presence of large amounts of data. This paper summarizes the results in transforming DL axioms to a set of function-free clauses of first-order logic which can be used for efficient, query oriented data reasoning. The described method has been implemented in a module of the DLog reasoner openly available on SourceForge to download

    Stability, Structure and Scale: Improvements in Multi-modal Vessel Extraction for SEEG Trajectory Planning

    Get PDF
    Purpose Brain vessels are among the most critical landmarks that need to be assessed for mitigating surgical risks in stereo-electroencephalography (SEEG) implantation. Intracranial haemorrhage is the most common complication associated with implantation, carrying signi cant associated morbidity. SEEG planning is done pre-operatively to identify avascular trajectories for the electrodes. In current practice, neurosurgeons have no assistance in the planning of electrode trajectories. There is great interest in developing computer assisted planning systems that can optimise the safety pro le of electrode trajectories, maximising the distance to critical structures. This paper presents a method that integrates the concepts of scale, neighbourhood structure and feature stability with the aim of improving robustness and accuracy of vessel extraction within a SEEG planning system. Methods The developed method accounts for scale and vicinity of a voxel by formulating the problem within a multi-scale tensor voting framework. Feature stability is achieved through a similarity measure that evaluates the multi-modal consistency in vesselness responses. The proposed measurement allows the combination of multiple images modalities into a single image that is used within the planning system to visualise critical vessels. Results Twelve paired datasets from two image modalities available within the planning system were used for evaluation. The mean Dice similarity coe cient was 0.89 ± 0.04, representing a statistically signi cantly improvement when compared to a semi-automated single human rater, single-modality segmentation protocol used in clinical practice (0.80 ±0.03). Conclusions Multi-modal vessel extraction is superior to semi-automated single-modality segmentation, indicating the possibility of safer SEEG planning, with reduced patient morbidity

    A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery

    Get PDF
    Epilepsy surgery is challenging and the use of 3D multimodality image integration (3DMMI) to aid presurgical planning is well-established. Multimodality image integration can be technically demanding, and is underutilised in clinical practice. We have developed a single software platform for image integration, 3D visualization and surgical planning. Here, our pipeline is described in step-by-step fashion, starting with image acquisition, proceeding through image co-registration, manual segmentation, brain and vessel extraction, 3D visualization and manual planning of stereoEEG (SEEG) implantations. With dissemination of the software this pipeline can be reproduced in other centres, allowing other groups to benefit from 3DMMI. We also describe the use of an automated, multi-trajectory planner to generate stereoEEG implantation plans. Preliminary studies suggest this is a rapid, safe and efficacious adjunct for planning SEEG implantations. Finally, a simple solution for the export of plans and models to commercial neuronavigation systems for implementation of plans in the operating theater is described. This software is a valuable tool that can support clinical decision making throughout the epilepsy surgery pathway

    The NifTK software platform for image-guided interventions: platform overview and NiftyLink messaging

    Get PDF
    PURPOSE: To perform research in image-guided interventions, researchers need a wide variety of software components, and assembling these components into a flexible and reliable system can be a challenging task. In this paper, the NifTK software platform is presented. A key focus has been high-performance streaming of stereo laparoscopic video data, ultrasound data and tracking data simultaneously. METHODS: A new messaging library called NiftyLink is introduced that uses the OpenIGTLink protocol and provides the user with easy-to-use asynchronous two-way messaging, high reliability and comprehensive error reporting. A small suite of applications called NiftyGuide has been developed, containing lightweight applications for grabbing data, currently from position trackers and ultrasound scanners. These applications use NiftyLink to stream data into NiftyIGI, which is a workstation-based application, built on top of MITK, for visualisation and user interaction. Design decisions, performance characteristics and initial applications are described in detail. NiftyLink was tested for latency when transmitting images, tracking data, and interleaved imaging and tracking data. RESULTS: NiftyLink can transmit tracking data at 1,024 frames per second (fps) with latency of 0.31 milliseconds, and 512 KB images with latency of 6.06 milliseconds at 32 fps. NiftyIGI was tested, receiving stereo high-definition laparoscopic video at 30 fps, tracking data from 4 rigid bodies at 20-30 fps and ultrasound data at 20 fps with rendering refresh rates between 2 and 20 Hz with no loss of user interaction. CONCLUSION: These packages form part of the NifTK platform and have proven to be successful in a variety of image-guided surgery projects. Code and documentation for the NifTK platform are available from http://www.niftk.org . NiftyLink is provided open-source under a BSD license and available from http://github.com/NifTK/NiftyLink. The code for this paper is tagged IJCARS-2014

    Feasibility of multimodal 3D neuroimaging to guide implantation of intracranial EEG electrodes

    Get PDF
    Since intracranial electrode implantation has limited spatial sampling and carries significant risk, placement has to be effective and efficient. Structural and functional imaging of several different modalities contributes to localising the seizure onset zone (SoZ) and eloquent cortex. There is a need to summarise and present this information throughout the pre/intra/post-surgical course

    Automated multiple trajectory planning algorithm for the placement of stereo-electroencephalography (SEEG) electrodes in epilepsy treatment.

    Get PDF
    PURPOSE: About one-third of individuals with focal epilepsy continue to have seizures despite optimal medical management. These patients are potentially curable with neurosurgery if the epileptogenic zone (EZ) can be identified and resected. Stereo-electroencephalography (SEEG) to record epileptic activity with intracranial depth electrodes may be required to identify the EZ. Each SEEG electrode trajectory, the path between the entry on the skull and the cerebral target, must be planned carefully to avoid trauma to blood vessels and conflicts between electrodes. In current clinical practice trajectories are determined manually, typically taking 2-3 h per patient (15 min per electrode). Manual planning (MP) aims to achieve an implantation plan with good coverage of the putative EZ, an optimal spatial resolution, and 3D distribution of electrodes. Computer-assisted planning tools can reduce planning time by quantifying trajectory suitability. METHODS: We present an automated multiple trajectory planning (MTP) algorithm to compute implantation plans. MTP uses dynamic programming to determine a set of plans. From this set a depth-first search algorithm finds a suitable plan. We compared our MTP algorithm to (a) MP and (b) an automated single trajectory planning (STP) algorithm on 18 patient plans containing 165 electrodes. RESULTS: MTP changed all 165 trajectories compared to MP. Changes resulted in lower risk (122), increased grey matter sampling (99), shorter length (92), and surgically preferred entry angles (113). MTP changed 42 % (69/165) trajectories compared to STP. Every plan had between 1 to 8 (median 3.5) trajectories changed to resolve electrode conflicts, resulting in surgically preferred plans. CONCLUSION: MTP is computationally efficient, determining implantation plans containing 7-12 electrodes within 1 min, compared to 2-3 h for MP

    SEEG trajectory planning: combining stability, structure and scale in vessel extraction

    Get PDF
    StereoEEG implantation is performed in patients with epilepsy to determine the site of the seizure onset zone. Intracranial haemorrhage is the most common complication associated to implantation carrying a risk that ranges from 0.6 to 2.7%, with significant associated morbidity. SEEG planning is done pre-operatively to identify avascular trajectories for the electrodes. In current practice neurosurgeons have no assistance in the planning of the electrode trajectories. There is great interest in developing computer assisted planning systems that can optimize the safety profile of electrode trajectories, maximizing the distance to critical brain structures. In this work, we address the problem of blood vessel extraction for SEEG trajectory planning. The proposed method exploits the availability of multi-modal images within a trajectory planning system to formulate a vessel extraction framework that combines the scale and the neighbouring structure of an object. We validated the proposed method in twelve multi-modal patient image sets. The mean Dice similarity coefficient (DSC) was 0.88 ± 0.03, representing a statistically significantly improvement when compared to the semi-automated single rater, single modality segmentation protocol used in current practice (DSC = 0.78 ± 0.02)
    corecore