65 research outputs found
Glutathione provides antioxidative defence and promotes microspore-derived embryo development in isolated microspore cultures of triticale (xTriticosecale Wittm.)
The efficiency of microspore embryogenesis (ME) is determined by the complex network of internal and environmental factors. Among them, the efficient defence against oxidative stress seems to be one of the most important. The present study confirms this hypothesis showing the positive effect of glutathionethe most abundant cellular antioxidanton ME in isolated microspore cultures of triticale (xTriticosecale Wittm.). For the first time, low temperature (LT) pre-treatment of tillers was combined with the exogenous application of glutathione and associated with the total activity of low-molecular weight antioxidants, the endogenous content and redox status of glutathione, and the effectiveness of ME. The results indicate that efficient antioxidative defence is the first, although not the only, prerequisite for effective ME. In responsive genotypes, LT alone stimulated antioxidative defence and decreased cell redox status, which was associated with increased cell viability and high frequency (ca. 20%) of microspore reprogramming. Application of glutathione had no effect either on the microspore viability or on the initial number of embryogenic microspores. However, it increased the number of embryo-like structures, probably by stimulating the next phases of its development. In recalcitrant genotypes, the main role of glutathione seems to be its participation in cell protection from oxidative stress. However, even enhanced antioxidative activity, which sustained cell viability and increased the number of embryogenic microspores, was insufficient for efficient haploid/doubled haploid plant production. Evidently, there are still other defective elements in the complex network of factors that regulate the process of ME
Comparison of prediction models for two different peripheral stem cell collection protocols in autologous patients. How to avoid errors in calculating total blood volume to process?
Introduction: Calculating accurate blood volume to process is a critical practice in apheresis planning; therefore, researchers try to develop dedicated prediction models. In this analysis, we have attempted to compare three algorithms for two different apheresis collection protocols.
Methods: In a retrospective study, we have analyzed 137 apheresis procedures performed on 100 autologous patients. Apheresis procedures were performed with the Spectra Optia apheresis device with two protocols: mononuclear cell collection (MNC) and continuous mononuclear cell collection (cMNC). Three algorithms: a model based on mean collection efficiency (CE2), a linear regression model, and a power regression model were validated by plotting collected CD34+ cell dose versus predicted CD34+ cell dose.
Results: All models showed high predictability for MNC procedure, a high correlation of predicted CD34+ yield and actual CD34+ yield (R2 = 0.9547; 0.9487; 0.9474 for CE2-based model, linear and power regression model, respectively). In contrast, alteration between models for the cMNC procedure was greater (R2 = 0.8049, 0.7970, and 0.8169) with a higher number of overpredictions. Further analysis revealed that for low CD34+ precounts blood volume to process, calculated with the three models, differ significantly up to fivefold times.
Conclusions: Utilizing regression models may lead to calculation errors, which can affect undercollection, repetition of apheresis, or even mobilization failure. Contrary to regression models, the model based on mean CE2 gave the most accurate prediction both for MNC and cMNC procedures. Although new prediction algorithms are created, this simple formula remains a reliable tool that promotes careful planning of apheresis, thus improving patient safety
Studies of discrete symmetries in decays of positronium atoms
A positronium - a bound state of electron and positron - is an eigenstate of parity and charge conjugation operators which decays into photons. It is a unique laboratory to study discrete symmetries whose precision is limited, in principle, by the effects due to the weak interactions expected at the level of 10−14 and photon-photon interactions expected at the level of 10−9.
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging as well as for physics studies involving detection of electronpositron annihilation into photons. The physics case covers the areas of discrete symmetries studies and genuine multipartite entanglement. The J-PET detector has high angular and time resolution and allows for determination of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for studies of discrete symmetries in decays of positronium atoms
Analysis procedure of the positronium lifetime spectra for the J-PET detector
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful
tool to study the nanostructures of porous materials. Positron Emissions
Tomography (PET) are devices allowing imaging of metabolic processes e.g. in
human bodies. A newly developed device, the J-PET (Jagiellonian PET), will
allow PALS in addition to imaging, thus combining both analyses providing new
methods for physics and medicine. In this contribution we present a computer
program that is compatible with the J-PET software. We compare its performance
with the standard program LT 9.0 by using PALS data from hexane measurements at
different temperatures. Our program is based on an iterative procedure, and our
fits prove that it performs as good as LT 9.0.Comment: 4 figures, 8 page
Sampling FEE and trigger-less DAQ for the J-PET scanner
In this paper, we present a complete Data Acquisition System (DAQ) together with the readout mechanisms for the J-PET tomography scanner. In general, detector readout chain is constructed out of Front-End Electronics (FEE) measurement devices such as Time-to-Digital or Analog-to-Digital Converters (TDCs or ADCs), data collectors and storage. We have developed a system capable for maintaining continuous readout of digitized data without preliminary selection. Such operation mode results in up to 8 Gbps data stream, therefore, it is required to introduce a dedicated module for on-line event building and feature extraction. The Central Controller Module, equipped with Xilinx Zynq SoC and 16 optical transceivers, serves as such true real time computing facility. Our solution for the continuous data recording (trigger-less) is a novel approach in such detector systems and assures that most of the information is preserved on the storage for further, high-level processing. Signal discrimination applies a unique method of using LVDS buffers located in the FPGA fabric
Feasibility study of the time reversal symmetry tests in decay of metastable positronium atoms with the J-PET detector
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in nonvanishing angular correlations of final state observables in the decay of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T-violation sensitive observables
Introduction of total variation regularization into filtered backprojection algorithm
In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method
A method to produce linearly polarized positrons and positronium atoms with the J-PET detector
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components
- …