103 research outputs found

    SYMULACJA ORAZ PORÓWNANIE WYBRANYCH TOPOLOGII SZYBKICH ŁADOWAREK

    Get PDF
    The article reviews the role of fast chargers in swiftly developing area of electrical energy storage devices. Energy efficient techniques implemented in fast chargers are shown, world standard requirements are mentioned. The models of the two topologies of the greatest interest: soft switched rectifier with diodes at the secondary side and synchronous rectifier are carried out and the results of simulations are presented. Higher efficiency of synchronous rectifier is proven.Artykuł jest poświęcony opisaniu roli, którą spełniają szybkie ładowarki w dynamicznie rozwijającej się branży zasobników energii elektrycznej. Pokazane są technologie wysokiej sprawności stosowane w szybkich ładowarkach. Wspomniane są również wymogi standardów światowych. Wykonane zostały modele dwóch najbardziej perspektywicznych topologii: miękko przełączany prostownik z diodami po stronie wtórnej oraz prostownik synchroniczny, wyniki przeprowadzonych symulacji zostały przeanalizowane. Udowodniona została wyższa sprawność prostownika synchronicznego

    UKŁAD BADAWCZY PRZEZNACZONY DO ANALIZY SYNCHRONIZACJI PRZEKSZTAŁTNIKÓW SIECIOWYCH PODCZAS ZAPADÓW NAPIĘCIA

    Get PDF
    The effective usage of the renewable energy is the topic that nowadays is more and more frequently discussed due to the fact that the demands made by the users concerning the payback period and the reliability of the components parts are constantly increasing. To achieve this, it is advisable to maximally increase the effectiveness of the converting systems and adjust them to the operation with the dynamically variable parameters of the power grid (i.e. by the application of the complex algorithms of vector steering). Such solutions lead to the effective conversion of the energy and the safe operation even during strong interference coming from the power grid. In the article, the author focuses on the important element of the converting system which is the synchronizing algorithm of the converter with the network (PLL). The article provides the results of the research conducted on the PLL algorithm simulated in the Matlab/Simulink software. Moreover, it outlines the comparison between the simulation results and the results obtained during the research on the real converter cooperating with the network model. The attractiveness of the presented article is increased by the application of the authorial emulator of the power grid.Efektywne wykorzystanie źródeł energii odnawialnej jest zagadnieniem coraz częściej poruszanym, z uwagi na rosnące wymagania stawiane przez użytkowników, głównie pod kątem czasu zwrotu inwestycji oraz niezawodności komponentów wchodzących w skład systemu. W tym celu należy maksymalizować sprawność układów przekształtnikowych oraz dostosować do pracy z dynamicznie zmieniającymi się parametrami sieci elektroenergetycznej (np. poprzez stosowanie złożonych algorytmów sterowania wektorowego). Takie działania prowadzą do efektywnego przekształcania energii elektrycznej oraz bezpiecznej pracy nawet podczas silnych zakłóceń pochodzących od sieci elektroenergetycznej. W artykule autor skupia się na niezwykle istotnym elemencie systemu przekształtnikowego jakim jest algorytm synchronizacji falownika z siecią (PLL). Przedstawione zostaną wyniki badań algorytmu PLL symulowanego w środowisku Matlab/Simulink oraz zostanie dokonane porównanie wyników symulacyjnych z wynikami uzyskanymi podczas badania rzeczywistego przekształtnika współpracującego z modelem sieci. Atrakcyjność przedstawianego artykułu podnosi zastosowanie autorskiego emulatora sieci elektroenergetycznej

    DYNAMICZNA REGULACJA MOCĄ PRZEKSZTAŁTNIKÓW SIECIOWYCH

    Get PDF
    The dynamic growth of the renewable energy sources sector causes that the Energy Regulatory Office introduces stricter and stricter grid codes about quality of the energy and dynamics of the sources. In the future, grid codes will require that the dynamic properties of the renewable source of energy is similar to the synchronous generator with the same power. Moreover, the renewable source of energy should damp power oscillation in power grid, and support it to stabilize the voltage. These causes lead us to use a high dynamic nonlinear control system – converters, installed between a source and a power grid. The paper presents a nonlinear controller improves the dynamic power control of the vector inverters’ systems. The analysis was made by using the MATLAB/Simulink software.Dynamicznie rozwijający się sektor źródeł odnawialnych zmusza urząd regulacji energetycznej do wprowadzania coraz bardziej rygorystycznych norm odnośnie jakości dostarczanej energii i dynamiki samych źródeł. W przyszłości przepisy będą wymagały by źródło energii odnawialnej własnościami dynamicznymi przypominało generator synchroniczny o równoważnej mocy. Ponadto źródło powinno własności tłumienia oscylacji mocy w systemie elektroenergetycznym i powinno wspomagać sieć w odbudowie napięcia. Powyższe przyczyny implikują sterowanie nieliniowe wysokiej dynamiki układów pośredniczących pomiędzy źródłem a siecią jakim są przekształtniki. Artykuł prezentuje regulator nieliniowy poprawiający dynamikę sterowania mocą w układach przekształtników wektorowych. Analizę dokonano za pomocą oprogramowania Matlab/SIMULINK

    An attempt at a typology of karst lakes in the Połaniec Basin (Małopolska Upland)

    Get PDF
    The main goal of the paper is to attempt a typology of karst lakes in the Połaniec Basin (Małopolska Upland). The typology was conducted on the basis of a dependence analysis of several essential morphometric parameters of lake basins. The considered data comprised 23 lakes with respect to15 morphometric features.The correlation analysis, mainly in a group of lakes that are located in single karst sinkholes, revealed that length and width of basins are distinctly associated features. It is also noticeable that basin shape determines lake volume, even though pools, that are characterised by similar water content volume, may differ in area. Moreover, an increase in maximum depth of basins does not necessarily imply any grow in their volume. Likewise, there is no prevalent dependence between basin area and maximum depth.The cluster analysis, among reasonable indications, singled out generally divisions of the considered lakes into two sets. One of the sets comprises Duży Staw and Dziki Staw, while the other consists of all the remaining lakes. Less frequent divisions into three indicated Duży Staw, Dziki Staw, and Czwarty Staw as leading lakes. Divisions into 19–22 clusters were also suggested, however it does not seem to be reliable. As a consequence, the cluster analysis elucidate that Duży Staw and Dziki Staw stand out the most from the other lakes. This remainder constitutes rather close to each other, but not an ideally uniform group of lakes

    Influence of particulate matter air pollution on exacerbation of chronic obstructive pulmonary disease depending on aerodynamic diameter and the time of exposure in the selected population with coexistent cardiovascular diseases

    Get PDF
    Introduction: Particulate matter air pollution constitutes an important factor affecting the course of various respiratory and cardiovasculardiseases. Two main monitored groups of particulate pollution are particulate matter with the aerodynamic diameterbelow 10 μm (PM10) and 2.5 μm (PM2.5). One of the most important respiratory diseases is chronic obstructive pulmonarydisease (COPD). Clinical presentation of COPD and cardiovascular diseases is similar and can cause complications during therapy.The study explores connection between particulate matter and COPD exacerbations in population with cardiovascular cause ofsymptoms excluded. Material and methods: Analysis was based on data from hospitalisations in the years 2006-2016 in the hospitals of UpperSilesian Agglomeration, Poland. The data were correlated with meteorological conditions and particulate matter concentrationsup to 90 days before hospital admission. Results: During the whole observation period no connection between PM10 concentration changes and COPD exacerbationswere observed. On the other hand PM 2,5 influence started to be significant on 14 day before admission (RR 1.06) and increasedup to maximal analysed period of 90 days (RR 1.32). Conclusions: Overall this study highlights the importance of particulate matter pollution emission impact on COPD exacerbationsin a long time perspective

    Aspergilloma in atypical localisation in severe asthma patient — case report

    Get PDF
      Pulmonary aspergillosis is a condition caused by the fungi Aspergillus. The form of disease depends on the immunological condition of the host organism and other concomitant illnesses that influence the pulmonary tissue. Asthmatic patients, in particular with the severe form of disease, who require the use of systemic glucocorticoids, are predisposed to develop allergic bronchopulmonary aspergillosis. Development of aspergilloma in the lung is preceded by the formation of pathological cavity in the course of another illness. The study reports a case of a severe asthma patient who developed aspergilloma in atypical localisation, without the presence of predisposing anatomical changes and illnesses.  

    Dyspnoea, cyanosis and digital clubbing in a 28-year-old patient as a result of hepatopulmonary syndrome

    Get PDF
    This paper presents a case of a young patient with cyanosis and digital clubbing, until then an active, sporty person. He sought medical assistance due to the growing dyspnoea and the drop of effort tolerance. Initially the diagnostic process focused on the confirmation of the suspicion of pulmonary fibrosis or another interstitial lung disease as causes of the respiratory failure. Due to the atypical presentation of the symptoms, reaching the final diagnosis of digestive system disease with lung involvement required a more thorough multifaceted diagnostics of a number of systems and organs

    WDROŻENIA PRZEMYSŁOWE MOTTEM PRAC BADAWCZYCH KATEDRY NAPĘDÓW I MASZYN ELEKTRYCZNYCH

    Get PDF
    The paper presents current offer of the implementation research at Electrical Drives and Electrical Machines Department at Lublin University of Technology. The offer was presented on the background of the historic activity of Department led by former managers. The practical nature of the research was emphasized. Implementation directions including, i.e. drives and passenger lifts control, electromechanical systems powered by renewable solar and wind power cooperation to the grid were distinguished. The active participation of the department employees and PhD students in adapting the educational offer to the market needs, as well as postgraduate staff training were also noticed.W artykule przedstawiono aktualną ofertę badawczo wdrożeniową Katedry Napędów i Maszyn Elektrycznych Politechniki Lubelskiej. Ofertę tą przedstawiono na tle historycznej działalności Katedry kierowanej przez poprzednich kierowników. Podkreślono praktyczny charakter badań. Wyróżniono kierunki prac wdrożeniowych obejmujących m.in. napędy i sterowanie dźwigów osobowych, układy elektromaszynowe zasilane ze źródeł fotowoltaicznych i współpracę elektrowni wiatrowych z siecią elektroenergetyczną. Zaznaczono również aktywny udział pracowników i doktorantów katedry w dostosowywaniu oferty dydaktycznej do potrzeb rynku i kształcenie kadr na studiach podyplomowych

    Samoistne włóknienie płuc współistniejące z rakiem płuc — przegląd piśmiennictwa

    Get PDF
    Samoistne włóknienie płuc (IPF) jest śródmiąższową chorobą płuc o złym rokowaniu. Chociaż mechanizmy prowadzące do powstania choroby nie zostały do końca wyjaśnione, wiąże się ona z rozwojem raka płuc, co dodatkowo pogarsza rokowanie. Liczne prace donoszą o współistnieniu IPF i raka płuc u 9,8%, a nawet 50% pacjentów, w zależności od czasu trwania obserwacji. Chociaż sformułowano wytyczne dotyczące leczenia raka płuc dla populacji ogólnej, brakuje powszechnie przyjętych zaleceń dla grupy chorych na IPF. Tymczasem różne zabiegi onkologiczne mogą prowadzić do nagłych zaostrzeń IPF (acute exacerbation of IPF). Autorzy pracy podjęli próbę dokonania przeglądu dostępnych danych na temat raka płuc u chorych, u których wcześniej rozpoznano IPF.Samoistne włóknienie płuc (IPF) jest śródmiąższową chorobą płuc o złym rokowaniu. Chociaż mechanizmy prowadzące do powstania choroby nie zostały do końca wyjaśnione, wiąże się ona z rozwojem raka płuc, co dodatkowo pogarsza rokowanie. Liczne prace donoszą o współistnieniu IPF i raka płuc u 9,8%, a nawet 50% pacjentów, w zależności od czasu trwania obserwacji. Chociaż sformułowano wytyczne dotyczące leczenia raka płuc dla populacji ogólnej, brakuje powszechnie przyjętych zaleceń dla grupy chorych na IPF. Tymczasem różne zabiegi onkologiczne mogą prowadzić do nagłych zaostrzeń IPF (acute exacerbation of IPF). Autorzy pracy podjęli próbę dokonania przeglądu dostępnych danych na temat raka płuc u chorych, u których wcześniej rozpoznano IPF

    Wpływ pyłowych zanieczyszczeń powietrza na zaostrzenia przewlekłej obturacyjnej choroby płuc w zależności od średnicy aerodynamicznej i czasu od ekspozycji w grupie pacjentów z chorobami układu sercowo-naczyniowego

    Get PDF
    WSTĘP: Pyłowe zanieczyszczenia powietrza stanowią istotny czynnik wpływający na przebieg chorób układu oddechowego oraz sercowo-naczyniowego. Dwiema głównymi grupami tych zanieczyszczeń poddanymi monitorowaniu są zanieczyszczenia pyłowe o średnicy aerodynamicznej poniżej 10 μm (PM10) i 2.5 μm (PM2.5). Wśród chorób układu oddechowego duże znaczenia ma przewlekła obturacyjna choroba płuc (POChP). Jej manifestacja kliniczna oraz manifestacja kliniczna chorób układu sercowo- -naczyniowego są podobne i może to stanowić utrudnienie w trakcie wyboru terapii. W pracy badano związek pomiędzy pyłowymi zanieczyszczeniami powietrza oraz zaostrzenia POChP w populacji w której wykluczono sercowo-naczyniowe tło dolegliwości. MATERIAŁ I METODY: Analizę oparto na danych dotyczących hospitalizacji na obszarze aglomeracji górnośląskiej w latach 2006–2016. Dane zostały skorelowane z danymi dotyczącymi warunków meteorologicznych i stężeniami zanieczyszczeń pyłowych do 90 dni przed dniem hospitalizacji. WYNIKI: W trakcie całego badanego okresu nie zaobserwowano związku między PM10 oraz zaostrzeniami POChP. Wpływ PM2,5 stawał się istotny od 14 dnia przed przyjęciem do szpitala (RR 1.06) i wzrastał aż do maksymalnego badanego okresu 90 dni (RR 1.32). WNIOSKI: Praca podkreśla istotność wpływu pyłowych zanieczyszczeń powietrza na zaostrzenia POChP w długie perspektywie czasowej.WSTĘP: Pyłowe zanieczyszczenia powietrza stanowią istotny czynnik wpływający na przebieg chorób układu oddechowego oraz sercowo-naczyniowego. Dwiema głównymi grupami tych zanieczyszczeń poddanymi monitorowaniu są zanieczyszczenia pyłowe o średnicy aerodynamicznej poniżej 10 μm (PM10) i 2.5 μm (PM2.5). Wśród chorób układu oddechowego duże znaczenia ma przewlekła obturacyjna choroba płuc (POChP). Jej manifestacja kliniczna oraz manifestacja kliniczna chorób układu sercowo- -naczyniowego są podobne i może to stanowić utrudnienie w trakcie wyboru terapii. W pracy badano związek pomiędzy pyłowymi zanieczyszczeniami powietrza oraz zaostrzenia POChP w populacji w której wykluczono sercowo-naczyniowe tło dolegliwości. MATERIAŁ I METODY: Analizę oparto na danych dotyczących hospitalizacji na obszarze aglomeracji górnośląskiej w latach 2006–2016. Dane zostały skorelowane z danymi dotyczącymi warunków meteorologicznych i stężeniami zanieczyszczeń pyłowych do 90 dni przed dniem hospitalizacji. WYNIKI: W trakcie całego badanego okresu nie zaobserwowano związku między PM10 oraz zaostrzeniami POChP. Wpływ PM2,5 stawał się istotny od 14 dnia przed przyjęciem do szpitala (RR 1.06) i wzrastał aż do maksymalnego badanego okresu 90 dni (RR 1.32). WNIOSKI: Praca podkreśla istotność wpływu pyłowych zanieczyszczeń powietrza na zaostrzenia POChP w długie perspektywie czasowej
    corecore