    Multicentre evaluation of a new point-of-care test for the determination of NT-proBNP in whole blood

    Get PDF
    Background: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. Methods: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. Results: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was ≤5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between −5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3mmol/L), icteric blood (bilirubin concentrations up to 582μmol/L), haemolytic blood (haemoglobin concentrations up to 62mg/L), biotin (up to 10mg/L), rheumatoid factor (up to 42IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165μL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. Conclusions: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting. Clin Chem Lab Med 2006;44:1269-7

    Analytical and Clinical Validation of a Point-of-Care Cardiac Troponin T Test with an Improved Detection Limit

    No full text
    Background: The point-of-care test Roche CARDIAC POC Troponin T (PoC TnT) is an improved assay which has been developed for the Roche cobas h 232 system. Methods: We performed a multicentre evaluation (four sites) to assess the analytical performance of the PoC TnT assay and to compare it with the central laboratory Elecsys (R) troponin T high sensitive (lab cTnT-hs) assay. Results: The relative mean differences found in method comparisons of PoC TnT vs. lab cTnT-hs ranged from -4.1% to +6.8%. Additionally, there was good concordance between PoC TnT and lab cTnT-hs for the number of samples with troponin T values below the measuring range of 40 ng/L. Lot-to-lot differences of PoC TnT ranged from -8.6% to +4.6%. Within-series coefficients of variation (CV) resulting from 81 ten-fold measurements with patient samples were 9.3%, 11.8%, and 12.9% in the low (40 to < 200 ng/L), medium (200 to < 600 ng/L), and high (600 to 2000 ng/L) measuring range, respectively. Using the system quality control, the mean CV for between-day imprecision was 11.3%. No interference was observed by triglycerides (up to 11.4 mmol/L), bilirubin (up to 376 mu mol/L), hemoglobin (up to 0.12 mmol/L), biotin (up to 30 mu g/L), rheumatoid factor (up to 200 IU/mL), or with 52 standard or cardiovascular drugs at therapeutic concentrations. There was no influence on the results by varying hematocrit values in a range from 25% to 53%. However, interferences with human anti-mouse antibodies were found. No significant influence on the results was found with PoC TnT by using sample volumes between 135 to 165 mu L. High troponin T concentrations up to 500 mu g/L did not lead to false low results, indicating no high-concentration hook effect. No cross-reactivity was found between the PoC TnT assay and human skeletal troponin T up to 1000 mu g/L (< 0.05%). Diagnostic sensitivity and specificity data of a subpopulation (23 patients) of this study are in agreement with results of another large pre-hospital study. Conclusions: The PoC TnT assay showed good analytical performance with excellent concordance with the calibration and reference laboratory method. It should therefore be suitable for its intended use in point-of-care settings

    Quellen- und Literaturverze

    No full text
    corecore