87 research outputs found

    Mesoscale organization of titania thin films enables oxygen sensing at room temperature

    Get PDF
    The application of titania materials to gas sensing devices based on thin films are of limited utility because they only operate at a high working temperature and exhibit in general a low sensitivity. To overcome these constraints, a new type of oxygen sensor based on mesoporous titania thin films working at room temperature under UV irradiation has been developed. The increased density of charge carriers induced by the photoconductive effect, has been used to enhance the sensitivity of the thin oxide layers. Mesostructured titania films have been prepared via self-assembly and thermal processing to remove the organic template obtaining anatase nanocrystals. The mesoporous films show a striking decrease of the current in the presence of oxygen that acts as an electron scavenger. Mesoporous samples exhibit a much higher response with respect to dense titania, due to the higher surface area and the larger number of surface defects.RAS is acknowledged for funding this project through CRP 30 L.R. 7/2007 ‘‘Bando Capitale Umano ad Alta Qualificazione annualita` 2015’’. This work was partially supported by the project ‘‘Mi ADATTI E L’ABBATTI’’- INSTM-Regione Lombardia project INSTMRL6

    Thermally Driven Selective Nanocomposite PS-PHB/MGC Nanofibrous Conductive Sensor for Air Pollutant Detection

    Get PDF
    The potentials to use the working temperature to tune both the sensitivity and the selectivity of a chemical sensor based on a nanostructured and nanocomposite polymer layer have been investigated and described. Thus, in a single step, a peculiar chemical layer was grown up onto IDE (Interdigitated Electrode) microtransducers by electrospinning deposition and using a single-needle strategy. The 3-component nanofibers, obtained from a mixture of polystyrene and polyhydroxibutyrate (insulating thermoplastics) and a known concentration of mesoporous graphitized carbon nanopowder, appeared highly rough on the surface and decorated with jagged islands but homogeneous in shape and diameter, with the nanofillers aggregated into clusters more or less densely packed through the fibers. The resulting sensor was conductive at room temperature and could work between 40 and 80°C without any apparent degradation. As the fibrous sensing layer was heated, the current increased and the sensitivity to some classes of VOCs such as an oxidizing gas drastically changed depending on the working temperature. More in detail, the sensor resulted highly sensitive and selective to acetic acid at 40°C but the sensitivity fell down, decreasing by 96%, when the sensor operated at 80°C. On the other hand, although an increase in temperature caused a general decrease in sensitivity to the tested VOCs (with a maximum of 14, 81, and 78% for amine, acetone and toluene, respectively) and water vapors (with a maximum of 55%), higher temperature affected only slightly the amine permeation, thus modifying the partial selectivity of the sensor to these chemicals. Conversely, when the operating temperature increased, the sensitivity to the detected gas, NO2, increased too, reporting a ~2 ppb limit of detection (LOD), thus confirming that the temperature was able to drive the selectivity of nanocomposite polymeric sensors

    Future evolution of the electronics nose: technology and electronic design

    No full text
    Lo scopo principale di questa tesi di Dottorato è uno studio approfondito sul sistema olfattivo artificiale (Naso Elettronico - EN) principalmente dedicato ad applicazioni spaziali. L'ambiente spaziale, piuttosto particolare destinato ad ospitare questo apparecchio ha richiesto particolare attenzione nella progettazione in modo da rispondere in maniera completa a tutte quelle caratteristiche elettriche e meccaniche che sono necessarie per superare tutti i test molto rigorosi di imposti dall'organizzazione internazionale di volo spaziale. La progettazione particolarmente orientata verso l'ottimizzazione generale del sistema, ha prodotto un fattore di qualità generale che, crediamo, influenzerà tutte le applicazioni terrestri nelle quali le prestazioni possono essere di un livello più basso. La strategia di progettazione adottata e seguita nel corso dei tre anni ha considerato i seguenti punti: a) miniaturizzazione dell'EN precedente (Libra Nose) senza ridurre la flessibilità digitale, includendo tutti i circuiti di interfaccia in un singolo FPGA; b) miglioramento della parte analogica, in particolare un nuovo disegno degli oscillatori e dell'interfaccia analogica verso i sistemi digitali di conteggio. A tale scopo una cura particolare al livello di progettazione è stata rivolta verso: la riduzione degli spazi occupati e il consumo, usando tensioni di alimentazione nel range che va da 5 V. a 3V. e perfino 1.8 V.: riduzione di tutte le interferenze fra i sensori; c) l’introduzione di due nuove tecniche che migliorano le prestazioni della coppia sensore-oscillatore. La prima si basa sull'utilizzazione di un singolo oscillatore per tutti i sensori QCM, riducendo lo spazio occupato per i circuiti da N a 1, dove la N è la dimensione della matrice di sensori. L'altra tecnica si basa sull'idea di commutazione di misura di frequenza su ogni oscillatore, uno alla volta accendendo e spegnendo l’oscillatore posto sotto misura. In tal modo si risparmia energia e si ha un rapporto migliore di segnale/disturbo; d) l'aumento delle prestazioni generali della parte di rilevamento riguardo alla possibilità di aumento della sensibilità verso i composti volatili, attraverso l'introduzione di un riscaldatore integrato sulla superficie del quarzo. L'idea di base considera il fatto che la presenza di un tal riscaldatore contribuisce, una volta attivato, alla riduzione del tempo di desorbimento e di conseguenza, riduce il tempo di recupero nella fase di pulizia. In questo contesto è stato utilizzato un sistema di controllo termico, basato sulla tecnica Δ. Tale sistema può migliorare la ‘tunabilità’ della sensibilità/selettività del sensore chimico (QCM) nei confronti di vari composti volatili. Inoltre, grazie all’utilizzazione del controllo termico sigma-delta, per la prima volta un sensore di flusso è stato integrato su QCM. Il risultato principale di questa tesi è stata l’accettazione a nome dell'agenzia europea spaziale (ESA) di un Naso Elettronico dedicato spazio che effettivamente è stato utilizzato nella missione di ENEIDE del 2005. Le prove passate per la valutazione dei criteri di costruzione ‘Spazio’ insieme ai risultati ottenuti durante la missione hanno confermato il successo della progettazione fatta nella prima parte di questa tesi. Ulteriori miglioramenti sono stati realizzati nell'ultimo periodo di tesi permettendo la realizzazione di uno strumento in grado di ‘vivere’ molto tempo nelle missioni interplanetarie e cosa di notevole importanza, di essere impiegato in molte delle applicazioni terrestri come: nell’industria, nell’alimentazione, nell’agricoltura, e nella medicina.The principal aim of this PhD thesis is a deep study of an artificial olfaction system (Electronic Nose – EN) mainly dedicated to space applications. The rather particular environment destined to host this apparatus has required a particular attention on many of the design details in order to infer about all those electrical and mechanical features which are necessary to overcome the very stringent stress parameters imposed by the space flight international organization. The request of a particular effort oriented to the overall optimization has produced a general quality factor which, we believe, will influence also all the terrestrial applications where performances may be of a lower level. The adopted strategy which was hold along the past three years has regarded the following points: a) miniaturization of the previous EN (Libra Nose) without reducing the digital flexibility and including all the interface circuits in a single FPGA; b) improvement of the analog part, in particular a new design of the oscillators, and of the analog interface toward the digital part. To this purpose a particular care at the design level has been paid towards: the reduction of occupied spaces, and consumption by using working supply voltages from 5 V. to 3V. and even 1,8 V.: reduction of about all the interferences among sensors; c) introduction of two new techniques improving the performances of the couple QCM sensor and oscillator; one of them is based on the utilization of a single oscillator for all the QCM sensors, reducing the occupied space for the circuits from N to 1, where N is the dimension of the sensor matrix; the other technique concerns the idea of performing the frequency measurement switching on each oscillator one in a time, saving in this way energy and achieving a better signal to noise ratio; d) increasing the overall performances of the sensing part with respect to the capability of increasing the sensitivity towards volatile compounds through the introduction of an integrated heater applied to one of the quartz surfaces. The basic idea considers the fact that the presence of such a heater contributes, once activated, to reduce the desorption time and, as a consequence, to reduce the recovery time in the cleaning phase. In this context by using a control system of the thermal sigma delta (TΔ) type, it has been proven that a better performance on the sensitivity/selectivity tuning with respect to the volatile compound adsorption, can be achieved. Moreover, by means of the utilization of the thermal sigma delta control, for the first time a flow sensor has been embedded on QCM. The main result of this thesis has been the acceptation on behalf of the International Space Agency of a space dedicated EN which was indeed used in the frame of the SOYUZ Mission. The passed space tests together with the results obtained during the Mission have confirmed the outstanding design done in the first part of this thesis. Further improvements have been achieved in the last thesis period allowing the availability of an instrument able to live long time in interplanetary Missions and as an important throughput, to be employed in many of the terrestrial applications regarding the industrial, food and agricultural, medicine, and ambient context

    Future evolution of the electronics nose: technology and electronic design

    No full text
    Lo scopo principale di questa tesi di Dottorato è uno studio approfondito sul sistema olfattivo artificiale (Naso Elettronico - EN) principalmente dedicato ad applicazioni spaziali. L'ambiente spaziale, piuttosto particolare destinato ad ospitare questo apparecchio ha richiesto particolare attenzione nella progettazione in modo da rispondere in maniera completa a tutte quelle caratteristiche elettriche e meccaniche che sono necessarie per superare tutti i test molto rigorosi di imposti dall'organizzazione internazionale di volo spaziale. La progettazione particolarmente orientata verso l'ottimizzazione generale del sistema, ha prodotto un fattore di qualità generale che, crediamo, influenzerà tutte le applicazioni terrestri nelle quali le prestazioni possono essere di un livello più basso. La strategia di progettazione adottata e seguita nel corso dei tre anni ha considerato i seguenti punti: a) miniaturizzazione dell'EN precedente (Libra Nose) senza ridurre la flessibilità digitale, includendo tutti i circuiti di interfaccia in un singolo FPGA; b) miglioramento della parte analogica, in particolare un nuovo disegno degli oscillatori e dell'interfaccia analogica verso i sistemi digitali di conteggio. A tale scopo una cura particolare al livello di progettazione è stata rivolta verso: la riduzione degli spazi occupati e il consumo, usando tensioni di alimentazione nel range che va da 5 V. a 3V. e perfino 1.8 V.: riduzione di tutte le interferenze fra i sensori; c) l’introduzione di due nuove tecniche che migliorano le prestazioni della coppia sensore-oscillatore. La prima si basa sull'utilizzazione di un singolo oscillatore per tutti i sensori QCM, riducendo lo spazio occupato per i circuiti da N a 1, dove la N è la dimensione della matrice di sensori. L'altra tecnica si basa sull'idea di commutazione di misura di frequenza su ogni oscillatore, uno alla volta accendendo e spegnendo l’oscillatore posto sotto misura. In tal modo si risparmia energia e si ha un rapporto migliore di segnale/disturbo; d) l'aumento delle prestazioni generali della parte di rilevamento riguardo alla possibilità di aumento della sensibilità verso i composti volatili, attraverso l'introduzione di un riscaldatore integrato sulla superficie del quarzo. L'idea di base considera il fatto che la presenza di un tal riscaldatore contribuisce, una volta attivato, alla riduzione del tempo di desorbimento e di conseguenza, riduce il tempo di recupero nella fase di pulizia. In questo contesto è stato utilizzato un sistema di controllo termico, basato sulla tecnica Δ. Tale sistema può migliorare la ‘tunabilità’ della sensibilità/selettività del sensore chimico (QCM) nei confronti di vari composti volatili. Inoltre, grazie all’utilizzazione del controllo termico sigma-delta, per la prima volta un sensore di flusso è stato integrato su QCM. Il risultato principale di questa tesi è stata l’accettazione a nome dell'agenzia europea spaziale (ESA) di un Naso Elettronico dedicato spazio che effettivamente è stato utilizzato nella missione di ENEIDE del 2005. Le prove passate per la valutazione dei criteri di costruzione ‘Spazio’ insieme ai risultati ottenuti durante la missione hanno confermato il successo della progettazione fatta nella prima parte di questa tesi. Ulteriori miglioramenti sono stati realizzati nell'ultimo periodo di tesi permettendo la realizzazione di uno strumento in grado di ‘vivere’ molto tempo nelle missioni interplanetarie e cosa di notevole importanza, di essere impiegato in molte delle applicazioni terrestri come: nell’industria, nell’alimentazione, nell’agricoltura, e nella medicina.The principal aim of this PhD thesis is a deep study of an artificial olfaction system (Electronic Nose – EN) mainly dedicated to space applications. The rather particular environment destined to host this apparatus has required a particular attention on many of the design details in order to infer about all those electrical and mechanical features which are necessary to overcome the very stringent stress parameters imposed by the space flight international organization. The request of a particular effort oriented to the overall optimization has produced a general quality factor which, we believe, will influence also all the terrestrial applications where performances may be of a lower level. The adopted strategy which was hold along the past three years has regarded the following points: a) miniaturization of the previous EN (Libra Nose) without reducing the digital flexibility and including all the interface circuits in a single FPGA; b) improvement of the analog part, in particular a new design of the oscillators, and of the analog interface toward the digital part. To this purpose a particular care at the design level has been paid towards: the reduction of occupied spaces, and consumption by using working supply voltages from 5 V. to 3V. and even 1,8 V.: reduction of about all the interferences among sensors; c) introduction of two new techniques improving the performances of the couple QCM sensor and oscillator; one of them is based on the utilization of a single oscillator for all the QCM sensors, reducing the occupied space for the circuits from N to 1, where N is the dimension of the sensor matrix; the other technique concerns the idea of performing the frequency measurement switching on each oscillator one in a time, saving in this way energy and achieving a better signal to noise ratio; d) increasing the overall performances of the sensing part with respect to the capability of increasing the sensitivity towards volatile compounds through the introduction of an integrated heater applied to one of the quartz surfaces. The basic idea considers the fact that the presence of such a heater contributes, once activated, to reduce the desorption time and, as a consequence, to reduce the recovery time in the cleaning phase. In this context by using a control system of the thermal sigma delta (TΔ) type, it has been proven that a better performance on the sensitivity/selectivity tuning with respect to the volatile compound adsorption, can be achieved. Moreover, by means of the utilization of the thermal sigma delta control, for the first time a flow sensor has been embedded on QCM. The main result of this thesis has been the acceptation on behalf of the International Space Agency of a space dedicated EN which was indeed used in the frame of the SOYUZ Mission. The passed space tests together with the results obtained during the Mission have confirmed the outstanding design done in the first part of this thesis. Further improvements have been achieved in the last thesis period allowing the availability of an instrument able to live long time in interplanetary Missions and as an important throughput, to be employed in many of the terrestrial applications regarding the industrial, food and agricultural, medicine, and ambient context

    Characterization of embedded temperature sensors on QCM in cryogenic environment

    No full text
    This work deals with the temperature characterization of embedded resistors deposited on a quartz crystal microbalance developed for thermogravimetric analyses in Space, i.e. the Contamination Assessment Microbalance project. The instrument allows in-situ thermogravimetric analyses thanks to the deposited resistors on the quartz crystals. Developed technology would improve the thermal control of the microbalance, but linearity of the deposited materials within the expected temperature range is of primary importance to provide accurate temperature measurement and get reliable results from the instrument thermogravimetric analyses. Thus, linearity of the Cr-Au material has been assessed down to cryogenic temperatures, lowest limit of the intended application

    Pocket Mercury-Vapour Detection System Employing a Preconcentrator Based on Au-TiO2 Nanomaterials

    No full text
    In environments polluted by mercury vapors that are potentially harmful to human health, there is a need to perform rapid surveys in order to promptly identify the sources of emission. With this aim, in this work, a low cost, pocket-sized portable mercury measurement system, with a fast response signal is presented. It consists of a preconcentrator, able to adsorb and subsequently release the mercury vapour detected by a quartz crystal microbalance (QCM) sensor. The preconcentrator is based on an adsorbing layer of titania/gold nanoparticles (TiO2NP/AuNPs), deposited on a micro-heater that acts as mercury thermal desorption. For the detection of the released mercury vapour, gold electrodes QCM (20 MHz) have been used. The experimental results, performed in simulated polluted mercury-vapour environments, showed a detection capability with a prompt response. In particular, frequency shifts (−118 Hz ± 2 Hz and −30 Hz ± 2 Hz) were detected at concentrations of 65 µg/m3 Hg0 and 30 µg/m3 Hg0, with sampling times of 60 min and 30 min, respectively. A system limit of detection (LOD) of 5 µg/m3 was evaluated for the 30 min sampling time
    • …
    corecore