102 research outputs found

    RELATIONSHIP BETWEEN MUSCLE ARCHITECTURE AND CONCENTRIC MOVEMENT VELOCITY DURING RESISTANCE EXERCISE

    Get PDF
    We compared muscle architecture with concentric movement velocity (CMV) during resistance exercise (RE). Twenty-four RE active males (21.4 ± 1.8 yrs) completed a dominant leg, single-leg leg extension at 75 & 90% of 1-repetition maximum (1RM) to failure. Ultrasound measures of the vastus lateralis (VL) were taken to assess pennation angle (PA), muscle thickness (MT) & fascicle length (FL). MT & 1RM were moderately correlated (r=0.32). Further, PA & FL were significantly correlated with 75% 1RM peak (P) & average (Av) CMV, (r=0.41-0.75) & FL/MT was strongly correlated with 75% 1RM P & Av CMV (r=0.64-0.76). Additionally, multiple regression suggested PA & FL were significantly associated with CMV. The data suggest FL, PA & FL/MT are importantly related to CMV during moderate-to-heavy RE, to failure

    COMPARISON OF CONCENTRIC MOVEMENT VELOCITY WITH PUSH BAND 2.0 AND VICON MOTION CAPTURE DURING RESISTANCE EXERCISES

    Get PDF
    We compared concentric movement velocity (CMV) measured with PUSH Bands (v.2.0) and a Vicon motion capture system (MC) during back squat (SQ) and bench press (BP) resistance exercises (RE) completed using a 2-dimensional smith machine. Twelve experienced resistance-trained males completed 10 repetitions at 50% of 1-repetiton maximum (1RM), and 6 repetitions at 75% 1RM for both BP and SQ. Use of Least-squares means contrasts suggests CMV measures did not differ between measurement technologies. Also, there is no indication of systematic bias between PUSH and MC. PUSH provides an accurate and reliable measurement of CMV during moderate and high intensity SQ and BP as compared with MC

    Observation of inhibited electron-ion coupling in strongly heated graphite

    Get PDF
    Creating non-equilibrium states of matter with highly unequal electron and lattice temperatures (Tele≠Tion) allows unsurpassed insight into the dynamic coupling between electrons and ions through time-resolved energy relaxation measurements. Recent studies on low-temperature laser-heated graphite suggest a complex energy exchange when compared to other materials. To avoid problems related to surface preparation, crystal quality and poor understanding of the energy deposition and transport mechanisms, we apply a different energy deposition mechanism, via laser-accelerated protons, to isochorically and non-radiatively heat macroscopic graphite samples up to temperatures close to the melting threshold. Using time-resolved x ray diffraction, we show clear evidence of a very small electron-ion energy transfer, yielding approximately three times longer relaxation times than previously reported. This is indicative of the existence of an energy transfer bottleneck in non-equilibrium warm dense matter

    Unconventional Transcriptional Response to Environmental Enrichment in a Mouse Model of Rett Syndrome

    Get PDF
    Background: Rett syndrome (RTT) is an X-linked postnatal neurodevelopmental disorder caused by mutations in the gene encoding methyl-CpG binding protein 2 (MeCP2) and one of the leading causes of mental retardation in females. RTT is characterized by psychomotor retardation, purposeless hand movements, autistic-like behavior and abnormal gait. We studied the effects of environmental enrichment (EE) on the phenotypic manifestations of a RTT mouse model that lacks MeCP2 (Mecp2 2/y). Principal Findings: We found that EE delayed and attenuated some neurological alterations presented by Mecp2 2/y mice and prevented the development of motor discoordination and anxiety-related abnormalities. To define the molecular correlate of this beneficial effect of EE, we analyzed the expression of several synaptic marker genes whose expression is increased by EE in several mouse models. Conclusions/Significance: We found that EE induced downregulation of several synaptic markers, suggesting that th

    Targets for high repetition rate laser facilities: Needs, challenges and perspectives

    Get PDF
    A number of laser facilities coming online all over the world promise the capability of high-power laser experiments with shot repetition rates between 1 and 10Ã\u82 Hz. Target availability and technical issues related to the interaction environment could become a bottleneck for the exploitation of such facilities. In this paper, we report on target needs for three different classes of experiments: Dynamic compression physics, electron transport and isochoric heating, and laser-driven particle and radiation sources. We also review some of the most challenging issues in target fabrication and high repetition rate operation. Finally, we discuss current target supply strategies and future perspectives to establish a sustainable target provision infrastructure for advanced laser facilities

    Novel experimental setup for megahertz X-ray diffraction in a diamond anvil cell at the High Energy Density (HED) instrument of the European X-ray Free-Electron Laser (EuXFEL)

    Get PDF
    The high-precision X-ray diffraction setup for work with diamond anvil cells (DACs) in interaction chamber 2 (IC2) of the High Energy Density instrument of the European X-ray Free-Electron Laser is described. This includes beamline optics, sample positioning and detector systems located in the multipurpose vacuum chamber. Concepts for pump-probe X-ray diffraction experiments in the DAC are described and their implementation demonstrated during the First User Community Assisted Commissioning experiment. X-ray heating and diffraction of Bi under pressure, obtained using 20 fs X-ray pulses at 17.8 keV and 2.2 MHz repetition, is illustrated through splitting of diffraction peaks, and interpreted employing finite element modeling of the sample chamber in the DAC

    Evaluation of Combined Artificial Intelligence and Radiologist Assessment to Interpret Screening Mammograms

    Get PDF
    Importance: Mammography screening currently relies on subjective human interpretation. Artificial intelligence (AI) advances could be used to increase mammography screening accuracy by reducing missed cancers and false positives. Objective: To evaluate whether AI can overcome human mammography interpretation limitations with a rigorous, unbiased evaluation of machine learning algorithms. Design, Setting, and Participants: In this diagnostic accuracy study conducted between September 2016 and November 2017, an international, crowdsourced challenge was hosted to foster AI algorithm development focused on interpreting screening mammography. More than 1100 participants comprising 126 teams from 44 countries participated. Analysis began November 18, 2016. Main Outcomes and Measurements: Algorithms used images alone (challenge 1) or combined images, previous examinations (if available), and clinical and demographic risk factor data (challenge 2) and output a score that translated to cancer yes/no within 12 months. Algorithm accuracy for breast cancer detection was evaluated using area under the curve and algorithm specificity compared with radiologists' specificity with radiologists' sensitivity set at 85.9% (United States) and 83.9% (Sweden). An ensemble method aggregating top-performing AI algorithms and radiologists' recall assessment was developed and evaluated. Results: Overall, 144 231 screening mammograms from 85 580 US women (952 cancer positive ≀12 months from screening) were used for algorithm training and validation. A second independent validation cohort included 166 578 examinations from 68 008 Swedish women (780 cancer positive). The top-performing algorithm achieved an area under the curve of 0.858 (United States) and 0.903 (Sweden) and 66.2% (United States) and 81.2% (Sweden) specificity at the radiologists' sensitivity, lower than community-practice radiologists' specificity of 90.5% (United States) and 98.5% (Sweden). Combining top-performing algorithms and US radiologist assessments resulted in a higher area under the curve of 0.942 and achieved a significantly improved specificity (92.0%) at the same sensitivity. Conclusions and Relevance: While no single AI algorithm outperformed radiologists, an ensemble of AI algorithms combined with radiologist assessment in a single-reader screening environment improved overall accuracy. This study underscores the potential of using machine learning methods for enhancing mammography screening interpretation

    Social Justice and Technocracy: Tracing the Narratives of Inclusive Education in the United States

    Get PDF
    Over the past two decades, the percentage of American students with disabilities educated in general classrooms with their nondisabled peers has risen by approximately fifty percent. This gradual but steady policy shift has been driven by two distinct narratives of organisational change. The social justice narrative espouses principles of equality and caring across human differences. The narrative of technocracy creates top-down, administrative pressure through hierarchical systems based on quantitative performance data. This article examines these two primary policy narratives of inclusive education in the United States, exploring the conceptual features of each and initiating an analysis of their application in the public schools

    Electron-ion temperature relaxation in warm dense hydrogen observed with picosecond resolved X-Ray scattering

    Get PDF
    Angularly resolved X-ray scattering measurements from fs-laser heated hydrogen have been used to determine the equilibration of electron and ion temperatures in the warm dense matter regime. The relaxation of rapidly heated cryogenic hydrogen is visualized using 5.5 keV X-ray pulses from the Linac Coherent Light (LCLS) source in a 1 Hz repetition rate pump-probe setting. We demonstrate that the electron-ion energy transfer is faster than quasi-classical Landau-Spitzer models that use ad hoc cutoffs in the Coulomb logarithm
    • 

    corecore