26 research outputs found
Comparative Endoscopic Anatomic Description of the Mitral Valvular Complex: a Cadaveric Study
Background We compared the aortic, left atrial, and apical approaches to visualize the mitral valve with the goal to investigate the endoscopic anatomy and give exact step-by-step descriptions of these views. Materials and Methods The mitral valvular complex of human cadaveric fresh hearts was investigated from three approaches using 0, 30, and 70 degrees rigid endoscopic optics. In 30 cases after the removal of the hearts, the endoscopes were introduced directly into the aortic root through an aortotomy, left atrium through a standard atriotomy, and apex of the heart through a transmural incision. In 10 cases, the in situ visualization was performed using standard surgical approaches, such as partial upper ministernotomy, right and left minithoracotomy. The investigation was performed first with the mitral valve open, then the left ventricle was filled with saline, and the valve was closed by clamping the aorta. Results For the visualization of ventricular surfaces of the mitral leaflets and the subvalvular apparatus, the apical approach was most optimal. The aortic approach had limitations at the posterior leaflet. Using the atrial approach, we did not obtain any direct visual information about the subvalvular apparatus with the valve closed. The atrial surfaces of the leaflets were best visible using both the atrial and apical approaches with the mitral valve open. In the case of a closed valve, the apical approach did not allow for an investigation of the atrial surfaces. The aortic approach was useful to visualize the atrial surface of the posterior leaflet with an opened valve. Conclusion In mitral valve repairs through the left atrium, an additional aortic or apical view could be useful to obtain functional information about the subvalvular apparatus by the sealing probe
Optical application and measurement of torque on microparticles of isotropic nonabsorbing material
We show how it is possible to controllably rotate or align microscopic
particles of isotropic nonabsorbing material in a TEM00 Gaussian beam trap,
with simultaneous measurement of the applied torque using purely optical means.
This is a simple and general method of rotation, requiring only that the
particle is elongated along one direction. Thus, this method can be used to
rotate or align a wide range of naturally occurring particles. The ability to
measure the applied torque enables the use of this method as a quantitative
tool--the rotational equivalent of optical tweezers based force measurement. As
well as being of particular value for the rotation of biological specimens,
this method is also suitable for the development of optically-driven
micromachines.Comment: 8 pages, 6 figure
Various clinical scenarios leading to development of the string sign of the internal thoracic artery after coronary bypass surgery: the role of competitive flow, a case series
<p>Abstract</p> <p>Background</p> <p>The left internal mammary artery (LIMA) is the choice for grafting of the left anterior descending coronary artery (LAD). One possible mechanism of the rare graft failure involve the presence of competitive flow.</p> <p>Method</p> <p>105 patients who had undergone coronary bypass grafting between 1998 and 2000 were included in this observational study. The recatheterizations were performed 28 months after the operations. The rate of patency the LIMA grafts was determined, and the cases with graft failure were analyzed.</p> <p>Results</p> <p>The LIMA graft was patent in 99 patients (94%). Six patients (6%) exhibited diffuse involution of the graft (string sign). The string sign was always associated with competitive flow as the basis of the LIMA graft involution. In one case quantitative re-evaluation of the preoperative coronary angiography revealed merely less than 50% diameter stenosis on the LAD with a nonligated side-branch of the LIMA. At recatheterization in two patients the pressure wire measurements demonstrated only a non-significant decrease of the fractional flow reserve (0.83 and 0.89), despite the 53% and 57% diameter stenosis in the angiogram. Another patient displayeda significant regression of the LAD lesion between the pre- and postoperative coronary angiography (from 76% to 44%) as the cause of the development of the competitive flow. In one instance, a radial artery graft on the LAD during a redo bypass operation resulted in competitive flow in the radial graft due to the greater diameter than that of the LIMA. In a further patient, competitive flow developed from a short sequential part of the LIMA graft between the nonsignificantly stenosed diagonal branch and the LAD, with involution of the main part of the graft to the diagonal branch.</p> <p>Conclusions</p> <p>The most common cause of the development of the string sign of a LIMA graft due to competitive flow is overassessment of the lesion of the LAD. Regression of a previous lesion or some other neighboring graft can also cause the phenomenon.</p
Abstracts from the 20th International Symposium on Signal Transduction at the Blood-Brain Barriers
https://deepblue.lib.umich.edu/bitstream/2027.42/138963/1/12987_2017_Article_71.pd
Anatomia chirurgicala a arterei radiale si a arcadelor palmare cu implicatii in cirurgia coronariana
Microfluidic Platforms Designed for Morphological and Photosynthetic Investigations of Chlamydomonas reinhardtii on a Single-Cell Level
Chlamydomonas reinhardtii is a model organism of increasing biotechnological importance, yet, the evaluation of its life cycle processes and photosynthesis on a single-cell level is largely unresolved. To facilitate the study of the relationship between morphology and photochemistry, we established microfluidics in combination with chlorophyll a fluorescence induction measurements. We developed two types of microfluidic platforms for single-cell investigations: (i) The traps of the Tulip device are suitable for capturing and immobilizing single cells, enabling the assessment of their photosynthesis for several hours without binding to a solid support surface. Using this Tulip platform, we performed high-quality non-photochemical quenching measurements and confirmed our earlier results on bulk cultures that non-photochemical quenching is higher in ascorbate-deficient mutants (Crvtc2-1) than in the wild-type. (ii) The traps of the Pot device were designed for capturing single cells and allowing the growth of the daughter cells within the traps. Using our most performant Pot device, we could demonstrate that the F-V/F-M parameter, an indicator of photosynthetic efficiency, varies considerably during the cell cycle. Our microfluidic devices, therefore, represent versatile platforms for the simultaneous morphological and photosynthetic investigations of C. reinhardtii on a single-cell level
Chrysin attenuates cardiomyocyte apoptosis and loss of intermediate filaments in a mouse model of mitoxantrone cardiotoxicity
y. Chrysin (CHR) is a natural flavonoid and is
present in high concentration in honey, propolis and
many plant extracts. The aim of the present study was to
evaluate the effects of CHR to reduce cardiomyocyte
apoptosis and loss of intermediate filaments in a mouse
model of mitoxantrone cardiotoxicity. Morphology of
the cardiomyocytes was determined by optic and
transmission electron microscopy and biochemistry
methods. The expression of Bcl-2, Bax and Caspase-3
were assessed by immunofluorecence. Tunel assay was
used to assess apoptosis in cardiomyocytes. In addition,
the distribution of desmin protein was evaluated using
immunohistochemistry. Our results show that MTX
treatment significantly increased serum levels of creatine
kinase isoenzyme (CK-MB), indicator of cardiac injury
and withdrawn under CHR protection. Expression levels
of Bcl-2 decreased, while those of Bax and caspase-3
increased following MTX treatment. 50 mg/kg of daily
CHR intake reduced Bax and caspase-3 immunopositivity and restored Bcl-2 levels to a value
comparable to the control. TUNEL (+) cardiomyocyte
nuclei of MTX group showed typical signs of apoptosis
which almost completely disappeared in response to 50
mg/kg CHR treatment. In parallel, an irregular
distribution and a weak expression of desmin is
associated with MTX induced cardiotoxic effects which
was also restored by CHR treatment.
In conclusion chrysin inhibits MTX-triggered
cardiomyocyte apoptosis via multiple pathways,
including decrease of the Bax/Bcl-2 ratio and caspase-3
expression along with preservation of the desmin
disarray