63 research outputs found

    Effect of heat shock preconditioning on ROS scavenging activity in rat skeletal muscle after downhill running

    Get PDF
    金沢大学附属病院整形外科The mechanisms of the protective effect conferred by heat shock preconditioning (HS) are currently unknown. The purpose of this study was to determine the effect of HS on muscle injury after downhill running and to address the mechanism of the effect. Female Wistar rats were assigned to three groups: HS, downhill running (E), and downhill running after heat shock preconditioning (HS + E). The HS and HS + E rats were placed in a heat chamber for 60 min (ambient temperature 42 ± 1.0°C) 48 h before downhill running. Reactive oxygen species (ROS) scavenging activity was determined by electron spin resonance (ESR), and heat shock protein 72 (HSP72) mRNA expression was measured in rat quadriceps femoris. Leukocyte infiltration and degenerated muscle fibers were determined histopathologically. ROS scavenging activity significantly increased at 3 days after HS (151 ± 18%) and HSP72 mRNA expression increased immediately after HS (1750 ± 1914%). No decrease in ROS scavenging activity was observed in the HS + E rats at 2 days after exercise compared with the E rats (102 ± 9% vs. 79 ± 5%). Degenerated muscle fibers in HS + E rats were significantly less than in E rats at 2, 3, and 7 days after exercise (0.8 ± 1.0 vs. 2.8 ± 1.6, 0.8 ± 1.0 vs. 1.8 ± 1.6, 0 vs. 0.3 ± 0.6, respectively). These data demonstrated that HS can reduce muscle injury after downhill running, and this effect may be mediated by increased ROS scavenging activity. Furthermore, HS may protect the antioxidant defense system in skeletal muscle by enhancing the adaptive HSP72 mRNA response.全文公開20091

    A New Serum Biomarker Set to Detect Mild Cognitive Impairment and Alzheimer’s Disease by Peptidome Technology

    Get PDF
    Background: Because dementia is an emerging problem in the world, biochemical markers of cerebrospinal fluid (CSF) and radio-isotopic analyses are helpful for diagnosing Alzheimer’s disease (AD). Although blood sample is more feasible and plausible than CSF or radiological biomarkers for screening potential AD, measurements of serum amyloid- β (Aβ), plasma tau, and serum antibodies for Aβ1 - 42 are not yet well established. Objective: We aimed to identify a new serum biomarker to detect mild cognitive impairment (MCI) and AD in comparison to cognitively healthy control by a new peptidome technology. Methods: With only 1.5μl of serum, we examined a new target plate “BLOTCHIP®” plus a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) to discriminate control (n = 100), MCI (n = 60), and AD (n = 99). In some subjects, cognitive Mini-Mental State Examination (MMSE) were compared to positron emission tomography (PET) with Pittsburgh compound B (PiB) and the serum probability of dementia (SPD). The mother proteins of candidate serum peptides were examined in autopsied AD brains. Results: Apart from Aβ or tau, the present study discovered a new diagnostic 4-peptides-set biomarker for discriminating control, MCI, and AD with 87% of sensitivity and 65% of specificity between control and AD (***p  Conclusion: The present serum biomarker set provides a new, rapid, non-invasive, highly quantitative and low-cost clinical application for dementia screening, and also suggests an alternative pathomechanism of AD for neuroinflammation and neurovascular unit damage

    Status of 48Ca double beta decay search in CANDLES

    Get PDF
    We study a strategy to reduce veto-time in the search for neutrino-less double-beta decay (0υββ) with CANDLES-III system. We develop a new likelihood analysis and apply it to our new Run010 data. We show that we can increase the un-vetoed live-time by 11.8%. Thanks to this improvements, We expect to increase a limit on the life-time of 0υββ by a factor of three by analyzing both Run009 and Run010 data

    DECIGO pathfinder

    Get PDF
    DECIGO pathfinder (DPF) is a milestone satellite mission for DECIGO (DECi-hertz Interferometer Gravitational wave Observatory) which is a future space gravitational wave antenna. DECIGO is expected to provide us fruitful insights into the universe, in particular about dark energy, a formation mechanism of supermassive black holes, and the inflation of the universe. Since DECIGO will be an extremely large mission which will formed by three drag-free spacecraft with 1000m separation, it is significant to gain the technical feasibility of DECIGO before its planned launch in 2024. Thus, we are planning to launch two milestone missions: DPF and pre-DECIGO. The conceptual design and current status of the first milestone mission, DPF, are reviewed in this article

    The status of DECIGO

    Get PDF
    DECIGO (DECi-hertz Interferometer Gravitational wave Observatory) is the planned Japanese space gravitational wave antenna, aiming to detect gravitational waves from astrophysically and cosmologically significant sources mainly between 0.1 Hz and 10 Hz and thus to open a new window for gravitational wave astronomy and for the universe. DECIGO will consists of three drag-free spacecraft arranged in an equilateral triangle with 1000 km arm lengths whose relative displacements are measured by a differential Fabry-Perot interferometer, and four units of triangular Fabry-Perot interferometers are arranged on heliocentric orbit around the sun. DECIGO is vary ambitious mission, we plan to launch DECIGO in era of 2030s after precursor satellite mission, B-DECIGO. B-DECIGO is essentially smaller version of DECIGO: B-DECIGO consists of three spacecraft arranged in an triangle with 100 km arm lengths orbiting 2000 km above the surface of the earth. It is hoped that the launch date will be late 2020s for the present

    Endothelial Dysfunction, Increased Arterial Stiffness, and Cardiovascular Risk Prediction in Patients With Coronary Artery Disease: FMD‐J (Flow‐Mediated Dilation Japan) Study A

    Get PDF
    BackgroundThe usefulness of vascular function tests for management of patients with a history of coronary artery disease is not fully known.Methods and ResultsWe measured flow‐mediated vasodilation (FMD) and brachial–ankle pulse wave velocity (baPWV) in 462 patients with coronary artery disease for assessment of the predictive value of FMD and baPWV for future cardiovascular events in a prospective multicenter observational study. The first primary outcome was coronary events, and the second primary outcome was a composite of coronary events, stroke, heart failure, and sudden death. During a median follow‐up period of 49.2 months, the first primary outcome occurred in 56 patients and the second primary outcome occurred in 66 patients. FMD above the cutoff value of 7.1%, derived from receiver‐operator curve analyses for the first and second primary outcomes, was significantly associated with lower risk of the first (hazard ratio, 0.27; 95% confidence interval, 0.06–0.74; P=0.008) and second (hazard ratio, 0.32; 95% confidence interval, 0.09–0.79; P=0.01) primary outcomes. baPWV above the cutoff value of 1731 cm/s was significantly associated with higher risk of the first (hazard ratio, 1.86; 95% confidence interval, 1.01–3.44; P=0.04) and second (hazard ratio, 2.19; 95% confidence interval, 1.23–3.90; P=0.008) primary outcomes. Among 4 groups stratified according to the combination of cutoff values of FMD and baPWV, stepwise increases in the calculated risk ratio for the first and second primary outcomes were observed.ConclusionsIn patients with coronary artery disease, both FMD and baPWV were significant predictors of cardiovascular events. The combination of FMD and baPWV provided further cardiovascular risk stratification

    FMD, PWV, and Cardiovascular Events

    Get PDF
    Background The usefulness of vascular function tests for management of patients with a history of coronary artery disease is not fully known. Methods and Results We measured flow‐mediated vasodilation (FMD) and brachial–ankle pulse wave velocity (baPWV) in 462 patients with coronary artery disease for assessment of the predictive value of FMD and baPWV for future cardiovascular events in a prospective multicenter observational study. The first primary outcome was coronary events, and the second primary outcome was a composite of coronary events, stroke, heart failure, and sudden death. During a median follow‐up period of 49.2 months, the first primary outcome occurred in 56 patients and the second primary outcome occurred in 66 patients. FMD above the cutoff value of 7.1%, derived from receiver‐operator curve analyses for the first and second primary outcomes, was significantly associated with lower risk of the first (hazard ratio, 0.27; 95% confidence interval, 0.06–0.74; P=0.008) and second (hazard ratio, 0.32; 95% confidence interval, 0.09–0.79; P=0.01) primary outcomes. baPWV above the cutoff value of 1731 cm/s was significantly associated with higher risk of the first (hazard ratio, 1.86; 95% confidence interval, 1.01–3.44; P=0.04) and second (hazard ratio, 2.19; 95% confidence interval, 1.23–3.90; P=0.008) primary outcomes. Among 4 groups stratified according to the combination of cutoff values of FMD and baPWV, stepwise increases in the calculated risk ratio for the first and second primary outcomes were observed. Conclusions In patients with coronary artery disease, both FMD and baPWV were significant predictors of cardiovascular events. The combination of FMD and baPWV provided further cardiovascular risk stratification

    DECIGO and DECIGO pathfinder

    Full text link
    corecore