271 research outputs found

    Friction Tubes to Generate Nanobubble Ozone Water with an Increased Half-Life for Virucidal Activity

    Full text link
    Nanobubbles and related technologies are expected to be highly utilized in water resource-based industries such as water purification, crops, horticulture, medicine, bio, and sterilization. Ozone, a chemical with high sterilizing power, is known as a natural substance that is reduced to oxygen and water after reacting with pollutants. Ozone water, which is generated by dissolving ozone in water, has been used in various industrial sectors such as medical care, food, and environment. Due to the unstable molecular state of ozone, however, it is difficult to produce, use, and supply ozone at industrial sites in a stable manner. This study proposed a method for constructing a system that can generate high-concentration ozone water in large quantities using low power in real time and maintaining the concentration of the generated ozone water over the long term. Friction tubes (called 'nanotube') played a key role to generate nanobubble ozone water with an increased half-life for virus killing activity. In addition, the safety of ozone water during its spray into the air was explained, and virucidal activity test cases for the influenza A (H1N1/A/PR8) and COVID-19 (SARS-CoV-2) virus using high-concentration ozone water as well as its technical efficacy were described

    Recent Changes in the Clinicopathologic Features of Korean Men with Prostate Cancer: A Comparison with Western Populations

    Get PDF
    Purpose : The aim of this study was to evaluate the recent changes in the clinicopathologic features of prostate cancer in Korea and to compare these features with those of Western populations. Materials and methods : We retrospectively reviewed the data of 1582 men undergoing radical prostatectomy for clinically localized prostate cancer between 1995 and 2007 at 10 institutions in Korea for comparison with Western studies. The patients were divided into two groups in order to evaluate the recent clinicopathological changes in prostate cancer: Group 1 had surgery between 1995 and 2003 (n=280) and Group 2 had surgery between 2004 and 2007 (n=1302). The mean follow-up period was 24 months. Results : Group 1 had a higher prostate-specific antigen level than Group 2 (10.0 ng/mL vs. 7.5 ng/mL, respectively; p<0.001) and a lower proportion of biopsy Gleason scores ≤6 (35.0% vs. 48.1%, respectively; p<0.001). The proportion of patients with clinical T1 stage was higher in Group 2 than in Group 1. Group 1 had a lower proportion of organ-confined disease (59.6% vs. 68.6%; p<0.001) and a lower proportion of Gleason scores ≤6 (21.3% vs. 33.0%; p<0.001), compared to Group 2. However, the relatively higher proportion of pathologic Gleason scores ≤6 in Group 2 was still lower than those of Western men, even though the proportion of organ-confined disease reached to that of Western series. Conclusion : Korean men with prostate cancer currently present better clinicopathologic parameters. However, in comparison, Korean men still show relatively worse pathologic Gleason scores than Western men.ope

    Pseudoinvasion in an Adenomatous Polyp of the Colon Mimicking Invasive Colon Cancer

    Get PDF
    Pseudoinvasion or pseudocarcinomatous invasion in an adenomatous polyp of the colon can be unfamiliar to an endoscopist. Pseudoinvasion in an adenomatous polyp represents prolapse of the adenomatous epithelium into its stalk. In most cases its morphology does not differ from of general adenomatous polyps, but in some cases it can morphologically mimic a malignant polyp with submucosal invasion due to mass-like lesioning of its stalk. This makes it difficult for endoscopists to differentiate pseudoinvasion in an adenoma from an invasive carcinoma by conventional endoscopy; instead, endoscopic ultrasonography can provide useful information for differentiating these conditions. We report on an 82-year-old man who presented with a large pedunculated polyp with a thick stalk in the sigmoid colon, which mimicked a submucosal invasive carcinoma. The patient was diagnosed with pseudoinvasion in an adenomatous polyp after segmental resection of the sigmoid colon

    Prefrontal functional connectivity analysis of cognitive decline for early diagnosis of mild cognitive impairment: A functional near-infrared spectroscopy study

    Get PDF
    Cognitive decline (CD) is a major symptom of mild cognitive impairment (MCI). Patients with MCI have an increased likelihood of developing Alzheimer&apos;s disease (AD). Although a cure for AD is currently lacking, medication therapies and/or daily training in the early stage can alleviate disease progression and improve patients&apos; quality of life. Accordingly, investigating CD-related biomarkers via brain imaging devices is crucial for early diagnosis. In particular, “portable” brain imaging devices enable frequent diagnostic checks as a routine clinical tool, and therefore increase the possibility of early AD diagnosis. This study aimed to comprehensively investigate functional connectivity (FC) in the prefrontal cortex measured by a portable functional near-infrared spectroscopy (fNIRS) device during a working memory (WM) task known as the delayed matching to sample (DMTS) task. Differences in prefrontal FC between healthy control (HC) (n = 23) and CD groups (n = 23) were examined. Intra-group analysis (one-sample t-test) revealed significantly greater prefrontal FC, especially left- and inter-hemispheric FC, in the CD group than in the HC. These observations could be due to a compensatory mechanism of the prefrontal cortex caused by hippocampal degeneration. Inter-group analysis (unpaired two-sample t-test) revealed significant intergroup differences in left- and inter-hemispheric FC. These attributes may serve as a novel biomarker for early detection of MCI. In addition, our findings imply that portable fNIRS devices covering the prefrontal cortex may be useful for early diagnosis of MCI. © 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement1

    Pharmacokinetic study of meropenem in healthy beagle dogs receiving intermittent hemodialysis

    Get PDF
    Meropenem, a second carbapenem antimicrobial agent with a broad spectrum of activity, is used to treat sepsis and resistant-bacterial infections in veterinary medicine. The objective of this study was to identify the pharmacokinetics of meropenem in dogs receiving intermittent hemodialysis (IHD) and to determine the proper dosing in renal failure patients receiving IHD. Five healthy beagle dogs were given a single i.v. dose of 24 mg/kg of meropenem and received IHD. The blood flow rate, dialysate flow, and ultrafiltration rate were maintained at 40 mL/min, 300 mL/min, and 40 mL/h, respectively. Blood samples were collected for 24 h from the jugular vein and from the extracorporeal arterial and venous line. Urine samples and dialysate were also collected. The concentrations of meropenem were assayed using HPLC/MS/MS determination. The peak plasma concentration was 116 +/- 37 mu g/mL at 15 min. The systemic clearance was 347 +/- 117 mL/h/kg, and the steady-state volume of distribution was 223 +/- 67 mL/kg. Dialysis clearance was 71.1 +/- 34.3 mL/h/kg, and the extraction ratio by hemodialysis was 0.455 +/- 0.150. The half-life (T-1/2) in dogs with IHD decreased compared with those without IHD, and the reduction in T1/2 was greater in renal failure patients than in normal patients. Sixty-nine percent and 21% of the administered drug were recovered by urine and dialysate in the unchanged form, respectively. In conclusion, additional dosing of 24 mg/kg of meropenem after dialysis could be necessary according to the residual renal function of the patient based on the simulated data.OAIID:RECH_ACHV_DSTSH_NO:T201621129RECH_ACHV_FG:RR00200001ADJUST_YN:EMP_ID:A003050CITE_RATE:1.279FILENAME:Byun_et_al-2016-Journal_of_Veterinary_Pharmacology_and_Therapeutics.pdfDEPT_NM:수의학과EMAIL:[email protected]_YN:YFILEURL:https://srnd.snu.ac.kr/eXrepEIR/fws/file/eb2b2d93-6cb2-4420-a374-90eb43215957/linkCONFIRM:
    corecore