477 research outputs found

    Ideas religiosas de Juan Manuel

    Get PDF

    Nonreciprocal second harmonic generation in a magnetoelectric material

    Full text link
    Nonreciprocal devices that allow the light propagation in only one direction are indispensable in photonic circuits and emerging quantum technologies. Contemporary optical isolators and circulators, however, require large size or strong magnetic fields because of the general weakness of magnetic light-matter interactions, which hinders their integration into photonic circuits. Aiming at stronger magneto-optical couplings, a promising approach is to utilize nonlinear optical processes. Here, we demonstrate nonreciprocal magnetoelectric second harmonic generation (SHG) in CuB2O4. SHG transmission changes by almost 100% in a magnetic-field reversal of just 10 mT. The observed nonreciprocity results from an interference between the magnetic-dipole- and electric-dipole-type SHG. Even though the former is usually notoriously smaller than the latter, it is found that a resonantly enhanced magnetic-dipole-transition has a comparable amplitude as non-resonant electric-dipole-transition, leading to the near-perfect nonreciprocity. This mechanism could form one of the fundamental bases of nonreciprocity in multiferroics, which is transferable to a plethora of magnetoelectric systems to realize future nonreciprocal and nonlinear-optical devices.Comment: 21 pages, 4 figure

    A New 100-GHz Band Front-End System with a Waveguide-Type Dual-Polarization Sideband-Separating SIS Receiver for the NRO 45-m Radio Telescope

    Full text link
    We developed a waveguide-type dual-polarization sideband-separating SIS receiver system of the 100-GHz band for the 45-m radio telescope at the Nobeyama Radio Observatory, Japan. This receiver is composed of an ortho-mode transducer and two sideband-separating SIS mixers, which are both based on the waveguide technique. The receiver has four intermediate frequency bands of 4.0--8.0 GHz. Over the radio frequency range of 80--120 GHz, the single-sideband receiver noise temperatures are 50--100 K and the image rejection ratios are greater than 10 dB. We developed new matching optics for the telescope beam as well as new IF chains for the four IF signals. The new receiver system was installed in the telescope, and we successfully observed the 12CO, 13CO and C18O emission lines simultaneously toward the Sagittarius B2 region to confirm the performance of the receiver system. The SSB noise temperature of the system, including the atmosphere, became approximately half of that of the previous receiver system. The Image Rejection Ratios (IRRs) of the two 2SB mixers were calculated from the 12CO and HCO+ spectra from the W51 giant molecular cloud, resulting in > 20 dB for one polarization and > 12 dB for the other polarization.Comment: 10 pages, 13 figures, Accepted for publication in PASJ, version with high resolution figures is available via http://www.nro.nao.ac.jp/library/report/list.htm

    The Current Status and Problems with the Implementation of Interprofessional Education in Japan.

    Get PDF
    Background: Although interprofessional education (IPE) has come to be considered essential in health and social care education programs, most IPE programs in Japan focus on clinical settings. However, following the 2011 Great East Japan Earthquake, IPE programs are considered essential for community development, especially in disaster-affected areas. To identify key issues for the development of IPE, we aimed to clarify the current status of IPE programs and problems in their implementation using an original questionnaire. Methods and Findings: The targets were 865 undergraduate courses that qualify students to take national registered health/social care examinations. Effective responses were received from 284 targets. Of these 284 respondents, 103 respondents had already implemented an IPE program and 181 respondents had not. Among the 103 respondents who had already implemented an IPE program, we found a tendency to collaborate with partners in clinical settings or in social settings. Furthermore, respondents who had implemented or were planning to implement an IPE program had difficulty with ‘interdisciplinary and/or extramural collaboration’ and ‘educational factors’. Conclusions: These difficulties could be considered barriers to developing effective IPE programs for community-based collaboration between health and social care professionals. Future research should investigate more specific solutions to these problems

    Potent Inhibitory Effects of D-tagatose on the Acid Production and Water-insoluble Glucan Synthesis of Streptococcus mutans GS5 in the Presence of Sucrose

    Get PDF
    We examined and compared the inhibitory effects of D-tagatose on the growth, acid production, and water-insoluble glucan synthesis of GS5, a bacterial strain of Streptococcus mutans, with those of xylitol, D-psicose, L-psicose and L-tagatose. GS5 was cultured for 12h in a medium containing 10オ (w/v) of xylitol, D-psicose, L-psicose, D-tagatose or L-tagatose, and the inhibitory effect of GS5 growth was assessed. Each sugar showed different inhibitory effects on GS5. Both D-tagatose and xylitol significantly inhibited the acid production and water-insoluble glucan synthesis of GS5 in the presence of 1オ (w/v) sucrose. However, the inhibitory effect of acid production by D-tagatose was significantly stronger than that of xylitol in presence of sucrose

    New 60-cm Radio Survey Telescope with the Sideband-Separating SIS Receiver for the 200 GHz Band

    Full text link
    We have upgraded the 60-cm radio survey telescope located in Nobeyama, Japan. We developed a new waveguide-type sideband-separating SIS mixer for the telescope, which enables the simultaneous detection of distinct molecular emission lines both in the upper and lower sidebands. Over the RF frequency range of 205-240 GHz, the single-sideband receiver noise temperatures of the new mixer are 40-100 K for the 4.0-8.0 GHz IF frequency band. The image rejection ratios are greater than 10 dB over the same range. For the dual IF signals obtained by the receiver, we have developed two sets of acousto-optical spectrometers and a telescope control system. Using the new telescope system, we successfully detected the 12CO (J=2-1) and 13CO (J=2-1) emission lines simultaneously toward Orion KL in 2005 March. Using the waveguide-type sideband-separating SIS mixer for the 200 GHz band, we have initiated the first simultaneous 12CO (J=2-1) and 13CO (J=2-1) survey of the galactic plane as well as large-scale mapping observations of nearby molecular clouds.Comment: 15 pages, 15 figures, Accepted for publication in PASJ, version with high resolution figures is available via http://www.nro.nao.ac.jp/~nakajima/vst1_2sb.pd

    formation of a laminar electron flow for 300GHz high-power pulsed gyrotron

    Get PDF
    This paper describes the design of a triode magnetron injection gun for use in a 200 kW, 300 GHz gyrotron. As power and frequency increase, the performance of the gyrotron becomes quite sensitive to the quality of the electron beam. Formation of a laminar electron flow is essential for the realization of a high quality beam with a small velocity spread. In this study, a new method is developed for a quantitative evaluation of the laminarity and is applied to optimize the electrode design. The laminarity depends not only on conventional design parameters such as the cathode slant angle but also on the spatial distribution of the electric field along the beam trajectory. In the optimized design, the velocity pitch factors, a, larger than 1.2 are obtained at 65 kV, 10A with spreads, Da, less than 5%

    Clinical Evaluation of the Peroral Cholangioscopy Using a New Videoscope

    Get PDF
    Peroral cholangioscopy (PCS) has been performed in 22 cases using XCHF-B200 (Olympus Optical Co.) since June 1995 and in 77 cases using CHF-B20 (Olympus Optical Co.) after EST from Jan. 1989. XCHF-B200 has a longer rigid portion of distal end and a smaller channel diameter than CHF-B20. The successful rate of PCS using XCHF-B200 (82%) was lower than that of CHF-B20 (89%). The vascular pattern and fine vertical groove of the bile duct mucosa were shown more clearly on the photographs obtained with XCHF-B200 than those obtained with CHF-B20. However, not enough biopsy specimens could be obtained because the channel diameter of XCHF-B200 was rather small
    corecore