151 research outputs found
Rotationally acquired four-dimensional optical coherence tomography of embryonic chick hearts using retrospective gating on the common central A-scan
We introduce a new method of rotational image acquisition for four-dimensional (4D) optical coherence tomography (OCT) of beating embryonic chick hearts. The rotational axis and the central A-scan of the OCT are identical. An out-of-phase image sequence covering multiple heartbeats is acquired at every angle of an incremental rotation of the deflection mirrors of the OCT system. Image acquisition is accomplished after a rotation of 180°. Comparison of a displayed live M-mode of the central A-scan with a reference M-mode allows instant detection of translational movements of the embryo. For calculation of 4D data sets, we apply an image-based retrospective gating algorithm using the phase information of the common central A-scan present in all acquired images. This leads to cylindrical three-dimensional data sets for every time step of the cardiac cycle that can be used for 4D visualization. We demonstrate this approach and provide a video of a beating Hamburger and Hamilton stage 16 embryonic chick heart generated from a 4D OCT data set using rotational image acquisition
Removal of temporary pacemaker after cardiac surgery in infants: A harmless procedure?
External pacemakers (PM) via temporary epicardial leads are routinely applied to infants and children during heart surgery, which usually, after an uneventful post surgical course, can be removed without complications. We report about two infants with complex congenital heart defects after cardiac surgery (arterial switch and Mustard operation for Transposition of the great arteries). Intraoperative these patients received temporary epicardial PM wires. Thirteen and 18 days post surgery, respectively, the PM wires were removed under electrocardiogram (ECG) monitoring. The patients showed acute ECG changes in terms of significant ST elevation during and after removing their pacing wires. Clinically, patients were stable and subsequent echocardiographic examination showed no evidence of myocardial dysfunction or pericardial effusion. In the course of time, patients showed no signs of arrhythmia or abnormal ECG changes. The decision to place temporary pacing wires during the cardiac surgery in patients with congenital heart defects should be considered carefully and their removal should occur under ECG monitoring as soon as the situation of the patient allows. It should be taken into consideration that a complication like this case may be related to delayed removal of temporary PM’s leads. © 2012 - IOS Press and the authors
Increasing the field-of-view of dynamic cardiac OCT via post-acquisition mosaicing without affecting frame-rate or spatial resolution
Optical coherence tomography (OCT) allows imaging dynamic structures and fluid flow within scattering tissue, such as the beating heart and blood flow in murine embryos. For any given system, the frame rate, spatial resolution, field-of-view (FOV), and signal-to-noise ratio (SNR) are interconnected: favoring one aspect limits at least one of the others due to optical, instrumentation, and software constraints. Here we describe a spatio-temporal mosaicing technique to reconstruct high-speed, high spatial-resolution, and large-field-of-view OCT sequences. The technique is applicable to imaging any cyclically moving structure and operates on multiple, spatially overlapping tiled image sequences (each sequence acquired sequentially at a given spatial location) and effectively decouples the (rigid) spatial alignment and (non-rigid) temporal registration problems. Using this approach we reconstructed full-frame OCT sequences of the beating embryonic rat heart (11.5 days post coitus) and compared it to direct imaging on the same system, demonstrating a six-fold improvement of the frame rate without compromising spatial resolution, FOV, or SNR
Sequential Turning Acquisition and Reconstruction (STAR) method for four-dimensional imaging of cyclically moving structures
Optical coherence tomography allows for dynamic, three-dimensional (3D+T) imaging of the heart within animal embryos. However, direct 3D+T imaging frame rates remain insufficient for cardiodynamic analysis. Previously, this limitation has been addressed by reconstructing 3D+T representations of the beating heart based on sets of two-dimensional image sequences (2D+T) acquired sequentially at high frame rate and in fixed (and parallel) planes throughout the heart. These methods either require additional hardware to trigger the acquisition of each 2D+T series to the same phase of the cardiac cycle or accumulate registration errors as the slices are synchronized retrospectively by pairs, without a gating signal. Here, we present a sequential turning acquisition and reconstruction (STAR) method for 3D+T imaging of periodically moving structures, which does not require any additional gating signal and is not prone to registration error accumulation. Similarly to other sequential cardiac imaging methods, multiple fast image series are consecutively acquired for different sections but in between acquisitions, the imaging plane is rotated around the center line instead of shifted along the direction perpendicular to the slices. As the central lines of all image-sequences coincide and represent measurements of the same spatial position, they can be used to accurately synchronize all the slices to a single inherent reference signal. We characterized the accuracy of our method on a simulated dynamic phantom and successfully imaged a beating embryonic rat heart. Potentially, this method can be applied for structural or Doppler imaging approaches with any direct space imaging modality such as computed tomography, ultrasound, or light microscopy
Measurement of absolute blood flow velocity in outflow tract of HH18 chicken embryo based on 4D reconstruction using spectral domain optical coherence tomography
The measurement of blood-plasma absolute velocity distributions with high spatial and temporal resolution in vivo is important for the investigation of embryonic heart at its early stage of development. We introduce a novel method to measure absolute blood flow velocity based on high speed spectral domain optical coherence tomography (OCT) and apply it to measure velocities across the heart outflow tract (OFT) of a chicken embryo (stage HH18). First, we use the OCT system to acquire 4D
[(x,y,z) + t] images of the OFT in vivo. Second, we reconstruct the 4D microstructural images and obtain the orientation of the OFT at its maximum expansion, from which the centerline of the OFT is calculated based on the OFT boundary segmentation. Assuming flow is parallel to the vessel orientation, the obtained centerline indicates the flow direction. Finally, the absolute flow velocity is evaluated based on the direction given by the centerline and the axial velocity obtained from Doppler OCT. Using this method, we compare flow velocity profiles at various positions along the chicken embryo OFT
Construction and establishment of a new environmental chamber to study real-time cardiac development
Heart development, especially the critical phase of cardiac looping, is a complex and intricate process that has not yet been visualized "live" over long periods of time. We have constructed and established a new environmental incubator chamber that provides stable conditions for embryonic development with regard to temperature, humidity, and oxygen levels. We have integrated a video microscope in the chamber to visualize the developing heart in real time and present the first "live" recordings of a chick embryo in shell-less culture acquired over a period of 2 days. The time-lapse images we show depict a significant time window that covers the most critical and typical morphogenetic events during normal cardiac looping. Our system is of interest to researchers in the field of embryogenesis, as it can be adapted to a variety of animal models for organogenesis studies including heart and limb development. © MICROSCOPY SOCIETY OF AMERICA 2007
- …