5,669 research outputs found

    Wideband, high efficiency optical modulator requires less than 10 watts drive power

    Get PDF
    Wideband optical modulation system operates with less than 10-watts drive power. It consists of an optical modulator and transistorized driver that combines small cross-section potassium dideuterium phosphate crystals with laser beam-condensing optics. Optical modulation systems may serve importantly in future space wideband communication systems

    Wideband high efficiency optical modulator Final report, 15 Feb. 1966 - 15 Mar. 1967

    Get PDF
    Design of wideband high efficiency optical modulation system tested over 100-MHz ban

    Mapping of serotype-specific, immunodominant epitopes in the NS-4 region of hepatitis C virus (HCV):use of type-specific peptides to serologically differentiate infections with HCV types 1, 2, and 3

    Get PDF
    The effect of sequence variability between different types of hepatitis C virus (HCV) on the antigenicity of the NS-4 protein was investigated by epitope mapping and by enzyme-linked immunosorbent assay with branched oligopeptides. Epitope mapping of the region between amino acid residues 1679 and 1768 in the HCV polyprotein revealed two major antigenic regions (1961 to 1708 and 1710 to 1728) that were recognized by antibody elicited upon natural infection of HCV. The antigenic regions were highly variable between variants of HCV, with only 50 to 60% amino acid sequence similarity between types 1, 2, and 3. Although limited serological cross-reactivity between HCV types was detected between peptides, particularly in the first antigenic region of NS-4, type-specific reactivity formed the principal component of the natural humoral immune response to NS-4. Type-specific antibody to particular HCV types was detected in 89% of the samples from anti-HCV-positive blood donors and correlated almost exactly with genotypic analysis of HCV sequences amplified from the samples by polymerase chain reaction. Whereas almost all blood donors appeared to be infected with a single virus type (97%), a higher proportion of samples (40%) from hemophiliacs infected from transfusion of non-heat-inactivated clotting factor contained antibody to two or even all three HCV types, providing evidence that long-term exposure may lead to multiple infection with different variants of HCV

    Discriminatory ability of next-generation tau PET tracers for Alzheimer's disease

    Get PDF
    A next generation of tau PET tracers for imaging of Alzheimer’s disease and other dementias has recently been developed. Whilst the new compounds have now entered clinical studies, there is limited information available to assess their suitability for clinical applications. Head-to-head comparisons are urgently needed to understand differences in the radiotracer binding profiles. We characterised the binding of the tau tracers PI2620, RO948, MK6240 and JNJ067 in human post-mortem brain tissue from a cohort of 25 dementia cases and age-matched controls, using quantitative phosphorimaging with tritium labelled radiotracers in conjunction with phospho-tau specific immunohistochemistry. The four tau radiotracers depicted tau inclusions composed of paired helical filaments with high specificity, both in cases with Alzheimer’s disease and in primary tauopathy cases with concomitant Alzheimer’s disease pathology. In contrast, cortical binding to primary tauopathy cases without paired helical filament tau was found to be within the range of age-matched controls. Off-target binding to monoamine oxidase B has been overcome, as demonstrated by heterologous blocking studies in basal ganglia tissue. The high variability of cortical tracer binding within the Alzheimer’s disease group followed the same pattern with each tracer, suggesting that all compounds are suited to differentiate Alzheimer’s disease from other dementias

    Nestin in immature embryonic neurons affects axon growth cone morphology and Semaphorin3a sensitivity

    Get PDF
    Correct wiring in the neocortex requires that responses to an individual guidance cue vary among neurons in the same location, and within the same neuron over time. Nestin is an atypical intermediate filament expressed strongly in neural progenitors and is thus used widely as a progenitor marker. Here we show a subpopulation of embryonic cortical neurons that transiently express nestin in their axons. Nestin expression is thus not restricted to neural progenitors, but persists for 2–3 d at lower levels in newborn neurons. We found that nestin-expressing neurons have smaller growth cones, suggesting that nestin affects cytoskeletal dynamics. Nestin, unlike other intermediate filament subtypes, regulates cdk5 kinase by binding the cdk5 activator p35. Cdk5 activity is induced by the repulsive guidance cue Semaphorin3a (Sema3a), leading to axonal growth cone collapse in vitro. Therefore, we tested whether nestin-expressing neurons showed altered responses to Sema3a. We find that nestin-expressing newborn neurons are more sensitive to Sema3a in a roscovitine-sensitive manner, whereas nestin knockdown results in lowered sensitivity to Sema3a. We propose that nestin functions in immature neurons to modulate cdk5 downstream of the Sema3a response. Thus, the transient expression of nestin could allow temporal and/or spatial modulation of a neuron’s response to Sema3a, particularly during early axon guidance

    Estimating logged-over lowland rainforest aboveground biomass in Sabah, Malaysia using airborne LiDAR data

    Get PDF
    Unprecedented deforestation and forest degradation in recent decades have severely depleted the carbon storage in Borneo. Estimating aboveground biomass (AGB) with high accuracy is crucial to quantifying carbon stocks for Reducing Emissions from Deforestation and Forest Degradation-plus implementation (REDD+). Airborne Light Detection and Ranging (LiDAR) is a promising remote sensing technology that provides fine-scale forest structure variability data. This paper highlights the use of airborne LiDAR data for estimating the AGB of a logged-over tropical forest in Sabah, Malaysia. The LiDAR data was acquired using an Optech Orion C200 sensor onboard a fixed wing aircraft. The canopy height of each LiDAR point was calculated from the height difference between the first returns and the Digital Terrain Model (DTM) constructed from the ground points. Among the obtained LiDAR height metrics, the mean canopy height produced the strongest relationship with the observed AGB. This single-variable model had a root mean squared error (RMSE) of 80.02 t ha-1 or 22.31% of the mean AGB, which performed exceptionally when compared with recent tropical rainforest studies. Overall, airborne LiDAR did provide fine-scale canopy height measurements for accurately and reliably estimating the AGB in a logged-over forest in Sabah, thus supporting the state's effort in realizing the REDD+ mechanism

    Myocardial biomechanics and the consequent differentially expressed genes of the left atrial ligation chick embryonic model of hypoplastic left heart syndrome

    Get PDF
    Left atrial ligation (LAL) of the chick embryonic heart is a model of the hypoplastic left heart syndrome (HLHS) where a purely mechanical intervention without genetic or pharmacological manipulation is employed to initiate cardiac malformation. It is thus a key model for understanding the biomechanical origins of HLHS. However, its myocardial mechanics and subsequent gene expressions are not well-understood. We performed finite element (FE) modeling and single-cell RNA sequencing to address this. 4D high-frequency ultrasound imaging of chick embryonic hearts at HH25 (ED 4.5) were obtained for both LAL and control. Motion tracking was performed to quantify strains. Image-based FE modeling was conducted, using the direction of the smallest strain eigenvector as the orientations of contractions, the Guccione active tension model and a Fung-type transversely isotropic passive stiffness model that was determined via micro-pipette aspiration. Single-cell RNA sequencing of left ventricle (LV) heart tissues was performed for normal and LAL embryos at HH30 (ED 6.5) and differentially expressed genes (DEG) were identified.After LAL, LV thickness increased by 33%, strains in the myofiber direction increased by 42%, while stresses in the myofiber direction decreased by 50%. These were likely related to the reduction in ventricular preload and underloading of the LV due to LAL. RNA-seq data revealed potentially related DEG in myocytes, including mechano-sensing genes (Cadherins, NOTCH1, etc.), myosin contractility genes (MLCK, MLCP, etc.), calcium signaling genes (PI3K, PMCA, etc.), and genes related to fibrosis and fibroelastosis (TGF-β, BMP, etc.). We elucidated the changes to the myocardial biomechanics brought by LAL and the corresponding changes to myocyte gene expressions. These data may be useful in identifying the mechanobiological pathways of HLHS

    Physical-vapor-deposited metal oxide thin films for pH sensing applications: Last decade of research progress

    Get PDF
    In the last several decades, metal oxide thin films have attracted significant attention for the development of various existing and emerging technological applications, including pH sensors. The mandate for consistent and precise pH sensing techniques has been increasing across various fields, including environmental monitoring, biotechnology, food and agricultural industries, and medical diagnostics. Metal oxide thin films grown using physical vapor deposition (PVD) with precise control over film thickness, composition, and morphology are beneficial for pH sensing applications such as enhancing pH sensitivity and stability, quicker response, repeatability, and compatibility with miniaturization. Various PVD techniques, including sputtering, evaporation, and ion beam deposition, used to fabricate thin films for tailoring materials’ properties for the advanced design and development of high-performing pH sensors, have been explored worldwide by many research groups. In addition, various thin film materials have also been investigated, including metal oxides, nitrides, and nanostructured films, to make very robust pH sensing electrodes with higher pH sensing performance. The development of novel materials and structures has enabled higher sensitivity, improved selectivity, and enhanced durability in harsh pH environments. The last decade has witnessed significant advancements in PVD thin films for pH sensing applications. The combination of precise film deposition techniques, novel materials, and surface functionalization strategies has led to improved pH sensing performance, making PVD thin films a promising choice for future pH sensing technologies
    corecore