30 research outputs found

    Adaptive Artificial Time Delay Control for Quadrotors under State-dependent Unknown Dynamics

    Get PDF
    Quadrotors are becoming more and more essential for applications such as payload delivery, inspection and search-and-rescue. Such operations pose considerable control challenges, especially when various (a priori unbounded) state-dependent unknown dynamics arises from payload variations, aerodynamic effects and from reaction forces while operating close to the ground or in a confined space. However, existing adaptive control strategies for quadrotors cannot handle unknown state-dependent uncertainties. We address such unsolved control challenge in this work via a novel adaptive method for artificial time delay control,where unknown dynamics is robustly compensated by using input and state measurements collected at immediate past time instant (i.e., artificially delayed). Closed-loop stability is established via Lyapunov theory. The effectiveness of this controller is validated using experimental results

    Efficacy and toxicity of SBRT in advanced hepatocellular carcinoma with portal vein tumor thrombosis — a retrospective study

    Get PDF
    BACKGROUND: The purpose of this study was to evaluate the outcome of stereotactic body radiation therapy (SBRT) in patients of unresectable hepatocellular carcinoma (HCC) complicated with portal vein tumor thrombosis (PVTT) who are also unsuitable for other locoregional therapies. MATERIALS AND METHODS: Between May 2018 and January 2020, twenty-nine patients with advanced unresectable HCCs, treated with SBRT, were enrolled in this retrospective audit. Patients of Child status A5-B7 and with healthy liver volume, ≥ 700 ccs were treated. Local control (LC), overall survival (OS), progression-free survival (PFS), PVTT opening rate, and effect of prognostic factors were analyzed. RESULTS: The median tumor diameter was 8.6 cm (5–14), and the median tumor volume was 275 cc (151–1196). The median SBRT dose prescription was 48 Gy in 6 fractions (32–50 Gy in 5–6 fractions). The median follow up was eight months (1–20), 1-year local control, progression-free survival, and overall survival were 95%, 53.4%, and 60%, respectively. Overall rate of grade III toxicity was less than 5%, and the most common toxicity was lymphocytopenia. Tumors of more than 350cc had worse OS and PFS when compared to tumors < 350 cc (median OS and PFS of tumors > 350 cc was 4 months and two months, p = .01 and .003, respectively). A total of fifteen patients progressed with the disease and the median time to progression was two months [1–4]. CONCLUSION: SBRT is safe and provides excellent local control in advanced HCC complicated with PVTT. The out of field failure pattern and time to failure in these patients highlights the need for adjuvant systemic therapy after completion of local treatment. Our data warrant the need for multimodality trials in this patient cohort

    Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma

    Get PDF
    BACKGROUND: A purpose of the study was to investigate the dosimetric impact of contrast media on dose calculation using average 4D contrast-enhanced computed tomography (4D-CECT) and delayed 4D-CT (d4D-CT) images caused by CT simulation contrast agents for stereotactic body radiation therapy (SBRT) of liver cases. MATERIALS AND METHODS: Fifteen patients of liver SBRT treated using the volumetric modulated arc therapy (VMAT) technique were selected retrospectively. 4D-CECT, and d4D-CT were acquired with the Anzai gating system and GE CT. For all patients, gross target volume (GTV) was contoured on the ten phases after rigid registration of both the contrast and delayed scans and merged to generate internal target volume (ITV) on average CT images. Region of interest (ROI) was drawn on contrast images and then copied to the delayed images after rigid registration of two average CT datasets. The treatment plans were generated for contrast enhanced average CT, delayed average CT and contrast enhanced average CT with electron density of the heart overridden. RESULTS: No significant dosimetric difference was observed in plans parameters (mean HU value of the liver, total monitor units, total control points, degree of modulation and average segment area) except mean HU value of the aorta amongst the three arms. All the OARs were evaluated and resulted in statistically insignificant variation (p > 0.05) using one way ANOVA analysis. CONCLUSIONS: Contrast enhanced 4D-CT is advantageous in accurate delineation of tumors and assessing accurate ITV. The treatment plans generated on average 4D-CECT and average d4D-CT have a clinically insignificant effect on dosimetric parameters

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M>70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0<e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Feature Based Automatic Text Summarization Methods: A Comprehensive State-of-the-Art Survey

    Get PDF
    With the advent of the World Wide Web, there are numerous online platforms that generate huge amounts of textual material, including social networks, online blogs, magazines, etc. This textual content contains useful information that can be used to advance humanity. Text summarization has been a significant area of research in natural language processing (NLP). With the expansion of the internet, the amount of data in the world has exploded. Large volumes of data make locating the required and best information time-consuming. It is impractical to manually summarize petabytes of data; hence, computerized text summarization is rising in popularity. This study presents a comprehensive overview of the current status of text summarizing approaches, techniques, standard datasets, assessment criteria, and future research directions. The summarizing approaches are assessed based on several characteristics, including approach-based, document-number-based, Summarization domain-based, document-language-based, output summary nature, etc. This study concludes with a discussion of many obstacles and research opportunities linked to text summarizing research that may be relevant for future researchers in this field
    corecore