6 research outputs found

    Psychometric Testing of the Hebrew Version of the European Heart Failure Self-Care Behaviour Scale

    No full text
    BACKGROUND: The assessment of self-care behaviour is important for tailoring care to patients and evaluating the effectiveness of heart failure (HF) disease-management programmes. The European HF Self-care Behaviour (EHFScB) scale is a validated instrument used worldwide. AIM: The purpose of the study was to evaluate psychometric properties of the Hebrew version of the nine-item EHFScB scale in Israeli patients with HF. METHOD: To develop the Hebrew version of the EHFScB scale, forward and back translation was performed. The psychometric evaluation was based on data from 102 patients with HF (mean age 61±12 yr, male 75%, New York Heart Association [NYHA] class II 42% and NYHA class III 51%) included in two cross-sectional studies performed in 2007 and 2015-2017 in an Israeli hospital. Content validity, construct validity, known-groups validity, and discriminant validity were assessed. Reliability was evaluated with internal consistency. RESULTS: Content validity and useability were confirmed by HF experts and patients with HF. Construct validity was tested using factor analysis and two factors were extracted (factor 1: consulting behaviour; factor 2: adherence to the regimen). Known-groups validity testing revealed a significant difference before and after an educational intervention in the total score (n=40 [41.6±23.8] vs [67.6±21.8]; p&lt;0.01). A weak correlation between the self-care score and health-related quality of life (r= -0.299, p&lt;0.01) was observed, showing that these concepts were related but not overlapping. Cronbach's alpha was 0.78 for the total scale, 0.76 for factor 1, and 0.68 for factor 2, suggesting that the internal consistency of this scale was acceptable. CONCLUSIONS: Our study provides support for the useability, validity, and reliability of the nine-item Hebrew version of the EHFScB scale.Funding agencies: Swedish National Science Council [K2013-69X-22302-01-3, 2016-01390]; Swedish National Science Council/Swedish research council for health, working life and welfare (VR-FORTE) [2014-4100]; Swedish Heart and Lung AssociationSwedish Heart-Lung Foundation [E0</p

    Self-care behaviours of patients with left ventricular assist devices in Israel: changes during the COVID-19 pandemic

    No full text
    AimsLeft ventricular assist devices (LVADs) support the hearts of patients with advanced heart failure. Following LVAD implantation, patients face a complex regimen of self-care behaviours including self-care maintenance, self-care monitoring and self-care management. However, during the COVID-19 pandemic, symptoms of anxiety and depression may have interfered with their self-care. Currently, little is known on how specific self-care behaviours of LVAD-implanted patients changed during the COVID-19 pandemic. We aim to describe the changes in self-care behaviours among patients with an implanted LVAD in Israel during the COVID-19 pandemic and explore the factors related to self-care behaviour change. MethodsA prospective observational cross-sectional study design. A convenience sample of 27 Israeli LVAD-implanted patients (mean age 62.4 +/- 9, 86% male, 78.6% living with a partner) completed the LVAD Self-Care Behaviour Scale (1 = never to 5 = always) and Hospital Anxiety and Depression Scale (0 = not at all to 3 = most of the time). Data were collected before and after the onset of the COVID-19 pandemic in Israel. Statistical analyses included paired t-tests, Pearsons correlations, and one-way repeated measures ANOVAs. ResultsDuring the COVID-19 pandemic, a significant decrease was found in patients adherence to checking and recording their LVAD speed, flow, power and PI (Pulsatility Index) (P = 0.05), checking their INR (P = 0.01), and daily weighing (P &amp;lt; 0.01). The prevalence of some behaviours (e.g. regularly exercising) increased in some patients and decreased in others. Patients living without a partner worsened their adherence to some of the self-care behaviours (e.g. taking medicines as prescribed), compared with those living with a partner (M-b = 5.0 +/- 0 and M-d = 5.0 +/- 0, delta = 0 vs. M-b = 5.0 +/- 0 and M-d = 4.6 +/- 0.9, delta = -0.4, respectively; F = 4.9, P = 0.04). Women, and not men, tended to improve their adherence to the self-care behaviour such as avoiding kinking, pulling, or moving the LVAD driveline at the exit site (M-b = 4.0 +/- 1.0 and M-d = 5.0 +/- 0, delta = 1.0 vs. M-b = 4.5 +/- 0.9 and M-d = 4.4 +/- 1.2, delta = -0.1, F = 4.7, P = 0.04, respectively). In total, 41% (11) patients reported neither anxiety nor depression, 11% (3) reported anxiety, 15% (4) reported depression, and 44% (12) reported both anxiety and depression. No associations between anxiety and/or depression and self-care behaviours were found. ConclusionsPriorities in self-care behaviours among patients with implanted LVAD changed after the onset of the COVID-19 pandemic. Factors that assisted with adherence to self-care behaviours included living with a partner and being female. The current results may guide further research on identifying behaviours that are at risk of not being maintained during a time of emergency.Funding Agencies|Nursing &amp; Allied Professional Training Grant from the ESC (European Society ofCardiology)</p

    Exergaming in patients with a left ventricular assist device : a feasibility study

    No full text
    Aims Exercise games (exergames) have been recently proposed as a mode of facilitating physical activity in patients with chronic diseases. Although patients supported with left ventricular assist devices (LVADs) benefit from physical activity, specific LVAD-related issues hinder their ability to exercise properly. The objective of this study was to assess the feasibility and safety of exergaming in LVAD-supported patients. Methods and results Eleven LVAD-supported patients were enrolled in a 4 week exergaming programme using Nintendo Wii console with five sport games. Patients were instructed to play for 30 min a day, 5 days a week. Data on exercise capacity and exergaming were collected by using the 6 min walk test (6MWT) and a daily self-report diary, respectively. Feasibility of using the console and its safety was assessed by a semi-structured patient interview. Quality of life was assessed by the Minnesota Living with Heart failure Questionnaire (MLHFQ) and the Cantrils Ladder of Life. Safety was assessed by patients report in interview and diary. The study group consisted of 10 male patients and 1 female patient, mean age of 67 +/- 7 years, of whom 10 were supported with the HeartMate 3 LVAD for a median of 10 (interquartile range 3, 21) months. Baseline exercise capacity assessed by the 6MWT ranged from 240 to 570 m (mean 448 +/- 112). After 4 weeks of exergaming, 6MWT distance increased from a mean of 448 +/- 112 (evaluated in six patients) to 472 +/- 113 m (P = 0.023). Patients Cantrils Ladder of Life score improved numerically from an average of 6.13 to 7.67, as did their MLHFQ score from 45.9 +/- 27 to 38.7 +/- 18, with higher and lower scores, respectively, reflecting higher quality of life. No specific LVAD-related safety issues regarding exergaming were reported. Conclusions Exergaming was found to be a safe and feasible mode for encouraging physical activity in LVAD-supported patients and carries a potential for improving exercise capacity and quality of life in these patients. Larger scale studies are warranted to further investigate the effect of exergaming in this patient population.Funding Agencies|Swedish National Science Council [2016-01390]</p

    Health-related quality of life in left ventricular assist device-supported patients

    No full text
    Aims This study aimed to evaluate the different health-related quality of life (HR-QoL) aspects in patients with both short-term and long-term duration LVAD support at pre-specified time intervals. Methods and results We performed a single-centre HR-QoL analysis of short-term and long-term LVAD-supported patients using the short version of the Kansas City Cardiomyopathy Questionnaire (KCCQ-12) and the Changes in Sexual Functioning Questionnaire along with a survey to evaluate patients social and driving routines. Data were collected at baseline and at 6 or 12 month follow-up. Included were 46 patients with a median time from LVAD implantation of 1.1 [inter-quartile range (IQR) 0.5, 2.6] years. The median KCCQ-12 summary score was 56 (IQR 29, 74) with most favourable scores in the symptom frequency domain [75 (IQR 50, 92)] and worse scores in the physical limitation [42 (IQR 25, 75)] and QoL [44 (IQR 25, 75)] domains. No significant changes were apparent during study follow-up [KCCQ-12 summary score 56 (IQR 35, 80)], and no significant correlation between the KCCQ-12 summary score and ventricular assist device-support duration was detected (r = -0.036, P = 0.812). Sexual dysfunction was noted across all domains with a cumulative score of 31 (IQR 22, 42). Seventy-six per cent of patients resumed driving after LVAD implantation, and 43% of patients reported they socialize with family and friends more frequently since surgery. Conclusions Short-term and long-term LVAD-supported patients had impaired HR-QoL and sexual function at baseline and at follow-up yet reported an improvement in social interactions and independency. A broader spectrum of patients reported HR-QoL measures should be integrated into the pre-LVAD implantation assessment and preparation

    Health‐related quality of life in left ventricular assist device‐supported patients

    No full text
    Aims This study aimed to evaluate the different health-related quality of life (HR-QoL) aspects in patients with both short-term and long-term duration LVAD support at pre-specified time intervals. Methods and results We performed a single-centre HR-QoL analysis of short-term and long-term LVAD-supported patients using the short version of the Kansas City Cardiomyopathy Questionnaire (KCCQ-12) and the Changes in Sexual Functioning Questionnaire along with a survey to evaluate patients social and driving routines. Data were collected at baseline and at 6 or 12 month follow-up. Included were 46 patients with a median time from LVAD implantation of 1.1 [inter-quartile range (IQR) 0.5, 2.6] years. The median KCCQ-12 summary score was 56 (IQR 29, 74) with most favourable scores in the symptom frequency domain [75 (IQR 50, 92)] and worse scores in the physical limitation [42 (IQR 25, 75)] and QoL [44 (IQR 25, 75)] domains. No significant changes were apparent during study follow-up [KCCQ-12 summary score 56 (IQR 35, 80)], and no significant correlation between the KCCQ-12 summary score and ventricular assist device-support duration was detected (r = -0.036, P = 0.812). Sexual dysfunction was noted across all domains with a cumulative score of 31 (IQR 22, 42). Seventy-six per cent of patients resumed driving after LVAD implantation, and 43% of patients reported they socialize with family and friends more frequently since surgery. Conclusions Short-term and long-term LVAD-supported patients had impaired HR-QoL and sexual function at baseline and at follow-up yet reported an improvement in social interactions and independency. A broader spectrum of patients reported HR-QoL measures should be integrated into the pre-LVAD implantation assessment and preparation
    corecore