64,177 research outputs found

    Molecular Gas and Star Formation in the SAURON Early-type Galaxies

    Get PDF
    We present the results of a survey of CO emission in 43 of the 48 representative E/S0 galaxies observed in the optical with the SAURON integral-field spectrograph. The CO detection rate is 12/43 or 28%. This is lower than previous studies of early-types but can probably be attributed to different sample selection criteria. As expected, earlier type, more luminous and massive galaxies have a relatively lower molecular gas content. We find that CO-rich galaxies tend to have higher H\beta but lower Fe5015 and Mgb absorption indices than CO-poor galaxies. Those trends appear primarily driven by the age of the stars, an hypothesis supported by the fact that the galaxies with the strongest evidence of star formation are also the most CO-rich. In fact, the early-type galaxies from the current sample appear to extend the well-known correlations between FIR luminosity, dust mass and molecular mass of other galaxy types. The star formation interpretation is also consistent with the SAURON galaxies' radio continuum and FIR flux ratios, and their inferred star formation efficiencies are similar to those in spiral galaxies. It thus appears that we have identified the material fueling (residual) star formation in early-type galaxies, and have demonstrated that it is actively being transformed. Nevertheless, the lack of strong correlations between the CO content and most stellar parameters is compatible with the idea that, in a significant number of sample galaxies, the molecular gas has been accreted from the outside and has properties rather independent from the old, pre-existing stellar component.Comment: 14 pages, 9 figures, accepted in MNRA

    Ozone reference models for the middle atmosphere (new CIRA)

    Get PDF
    Models of ozone vertical structure were generated that were based on multiple data sets from satellites. The very good absolute accuracy of the individual data sets allowed the data to be directly combined to generate these models. The data used for generation of these models are from some of the most recent satellite measurements over the period 1978 to 1983. A discussion is provided of validation and error analyses of these data sets. Also, inconsistencies in data sets brought about by temporal variations or other factors are indicated. The models cover the pressure range from from 20 to 0.003 mb (25 to 90 km). The models for pressures less than 0.5 mb represent only the day side and are only provisional since there was limited longitudinal coverage at these levels. The models start near 25 km in accord with previous COSPAR international reference atmosphere (CIRA) models. Models are also provided of ozone mixing ratio as a function of height. The monthly standard deviation and interannual variations relative to zonal means are also provided. In addition to the models of monthly latitudinal variations in vertical structure based on satellite measurements, monthly models of total column ozone and its characteristic variability as a function of latitude based on four years of Nimbus 7 measurements, models of the relationship between vertical structure and total column ozone, and a midlatitude annual mean model are incorporated in this set of ozone reference atmospheres. Various systematic variations are discussed including the annual, semiannual, and quasibiennial oscillations, and diurnal, longitudinal, and response to solar activity variations

    Selective COX-2 inhibitors and risk of myocardial infarction

    Get PDF
    Selective inhibitors of cyclooxygenase- 2 ( COX- 2, ` coxibs') are highly effective anti-inflammatory and analgesic drugs that exert their action by preventing the formation of prostanoids. Recently some coxibs, which were designed to exploit the advantageous effects of non- steroidal anti-inflammatory drugs while evading their side effects, have been reported to increase the risk of myocardial infarction and atherothrombotic events. This has led to the withdrawal of rofecoxib from global markets, and warnings have been issued by drug authorities about similar events during the use of celecoxib or valdecoxib/ parecoxib, bringing about questions of an inherent atherothrombotic risk of all coxibs and consequences that should be drawn by health care professionals. These questions need to be addressed in light of the known effects of selective inhibition of COX- 2 on the cardiovascular system. Although COX- 2, in contrast to the cyclooxygenase-1 ( COX- 1) isoform, is regarded as an inducible enzyme that only has a role in pathophysiological processes like pain and inflammation, experimental and clinical studies have shown that COX- 2 is constitutively expressed in tissues like the kidney or vascular endothelium, where it executes important physiological functions. COX- 2- dependent formation of prostanoids not only results in the mediation of pain or inflammatory signals but also in the maintenance of vascular integrity. Especially prostacyclin ( PGI(2)), which exerts vasodilatory and antiplatelet properties, is formed to a significant extent by COX- 2, and its levels are reduced to less than half of normal when COX- 2 is inhibited. This review outlines the rationale for the development of selective COX- 2 inhibitors and the pathophysiological consequences of selective inhibition of COX- 2 with special regard to vasoactive prostaglandins. It describes coxibs that are currently available, evaluates the current knowledge on the risk of atherothrombotic events associated with their intake and critically discusses the consequences that should be drawn from these insights. Copyright (C) 2005 S. Karger AG, Basel

    Time to publication for NIHR HTA programme-funded research: a cohort study

    Get PDF
    ObjectiveTo assess the time to publication of primary research and evidence syntheses funded by the National Institute for Health Research (NIHR) Health Technology Assessment (HTA) Programme published as a monograph in Health Technology Assessment and as a journal article in the wider biomedical literature.Study designRetrospective cohort study.SettingPrimary research and evidence synthesis projects funded by the HTA Programme were included in the cohort if they were registered in the NIHR research programmes database and was planned to submit the draft final report for publication in Health Technology Assessment on or before 9 December 2011.Main outcome measuresThe median time to publication and publication at 30?months in Health Technology Assessment and in an external journal were determined by searching the NIHR research programmes database and HTA Programme website.ResultsOf 458 included projects, 184 (40.2%) were primary research projects and 274 (59.8%) were evidence syntheses. A total of 155 primary research projects had a completion date; the median time to publication was 23?months (26.5 and 35.5?months to publish a monograph and to publish in an external journal, respectively) and 69% were published within 30?months. The median time to publication of HTA-funded trials (n=126) was 24?months and 67.5% were published within 30?months. Among the evidence syntheses with a protocol online date (n=223), the median time to publication was 25.5?months (28?months to publication as a monograph), but only 44.4% of evidence synthesis projects were published in an external journal. 65% of evidence synthesis studies had been published within 30.0?months.ConclusionsResearch funded by the HTA Programme publishes promptly. The importance of Health Technology Assessment was highlighted as the median time to publication was 9?months shorter for a monograph than an external journal article

    Becoming a teacher: conceptual and practice development in the learning and skills sector

    Get PDF
    Drawing on a mixed-methods study of in-service learning and skills sector (LSS) trainees, comprising beginning- and end-of-year surveys and six longitudinal case studies together with literature on traineesā€™ development in the LSS, schools and higher education sectors, conceptual and practice development continua are proposed. Conceptions become more multi-dimensional and increasingly link teaching and learning whilst initial concern with the practicalities of teaching is followed by recognition of learnersā€™ needs. Next, greater emphasis is placed on learner autonomy and catering for individualsā€™ needs and finally assessment and evaluation is used systematically to shape practice. The continua offer an understanding of the subtleties and complexities of trainee development allowing for different starting and end points and accommodating varied work contexts. I argue that this provides a more adequate basis for the development of initial teacher education (ITE) than the prescriptive approach embedded within recent LSS ITE policy reforms

    Calibration of the spin-scan ozone imager aboard the dynamics Explorer 1 satellite

    Get PDF
    The calibration technique, which contains the calibrated backscattered radiance values necessary for performing the calibrations, is presented. The calibration constants for September to October 1981 to determine total columnar ozone from the Spin-Scan Ozone Imager (SOI), which is a part of the auroral imaging instrumentation aboard the Dynamics Explorer 1 Satellite, are provided. The precision of the SOI-derived total columnar ozone is estimated to be better than 2.4 percent. Linear regression analysis was used to calculate correlation coefficients between total columnar ozone obtained from Dobson ground stations and SOI which indicate that the SOI total columnar ozone determination is equally accurate for clear or cloudy weather conditions

    Photo sensor array technology development

    Get PDF
    The development of an improved capability photo sensor array imager for use in a Viking '75 type facsimile camera is presented. This imager consists of silicon photodiodes and lead sulfide detectors to cover a spectral range from 0.4 to 2.7 microns. An optical design specifying filter configurations and convergence angles is described. Three electronics design approaches: AC-chopped light, DC-dual detector, and DC-single detector, are investigated. Experimental and calculated results are compared whenever possible using breadboard testing and tolerance analysis techniques. Results show that any design used must be forgiving of the relative instability of lead sulfide detectors. A final design using lead sulfide detectors and associated electronics is implemented by fabrication of a hybrid prototype device. Test results of this device show a good agreement with calculated values
    • ā€¦
    corecore