60 research outputs found

    Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls.</p> <p>Methods</p> <p>Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS) on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study.</p> <p>Results</p> <p>The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; <it>P </it>< 0.001); good concurrent validity was only achieved for hip abduction and internal rotation, with intraclass correlation coefficients (ICC) of 0.94 and 0.88, respectively. Both devices detected lower hip abduction ROM in patients compared to controls (<it>P </it>< 0.01). Test-retest reliability was good with ICCs higher 0.90, except for hip adduction (0.82-0.84). Reliability estimates did not differ between the goniometer and the ETS.</p> <p>Conclusions</p> <p>The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion) rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.</p

    Effectiveness and Cost-effectiveness of Outpatient Physiotherapy After Knee Replacement for Osteoarthritis: Study Protocol for a Randomised Controlled Trial

    Get PDF
    Background: Primary total knee replacement is a common operation that is performed to provide pain relief and restore functional ability. Inpatient physiotherapy is routinely provided after surgery to enhance recovery prior to hospital discharge. However, international variation exists in the provision of outpatient physiotherapy after hospital discharge. While evidence indicates that outpatient physiotherapy can improve short-term function, the longer term benefits are unknown. The aim of this randomised controlled trial is to evaluate the long-term clinical effectiveness and cost-effectiveness of a 6-week group-based outpatient physiotherapy intervention following knee replacement. Methods/design: Two hundred and fifty-six patients waiting for knee replacement because of osteoarthritis will be recruited from two orthopaedic centres. Participants randomised to the usual-care group (n = 128) will be given a booklet about exercise and referred for physiotherapy if deemed appropriate by the clinical care team. The intervention group (n = 128) will receive the same usual care and additionally be invited to attend a group-based outpatient physiotherapy class starting 6 weeks after surgery. The 1-hour class will be run on a weekly basis over 6 weeks and will involve task-orientated and individualised exercises. The primary outcome will be the Lower Extremity Functional Scale at 12 months post-operative. Secondary outcomes include: quality of life, knee pain and function, depression, anxiety and satisfaction. Data collection will be by questionnaire prior to surgery and 3, 6 and 12 months after surgery and will include a resource-use questionnaire to enable a trial-based economic evaluation. Trial participation and satisfaction with the classes will be evaluated through structured telephone interviews. The primary statistical and economic analyses will be conducted on an intention-to-treat basis with and without imputation of missing data. The primary economic result will estimate the incremental cost per quality-adjusted life year gained from this intervention from a National Health Services (NHS) and personal social services perspective. Discussion: This research aims to benefit patients and the NHS by providing evidence on the long-term effectiveness and cost-effectiveness of outpatient physiotherapy after knee replacement. If the intervention is found to be effective and cost-effective, implementation into clinical practice could lead to improvement in patients’ outcomes and improved health care resource efficiency

    Measuring hip muscle strength in patients with femoroacetabular impingement and other hip pathologies

    Get PDF
    Objectives\textbf{Objectives} The aim of this study was to systematically review the literature on measurement of muscle strength in patients with femoroacetabular impingement (FAI) and other pathologies and to suggest guidelines to standardise protocols for future research in the field. Methods\textbf{Methods} The Cochrane and PubMed libraries were searched for any publications using the terms ‘hip’, ‘muscle’, ‘strength’, and ‘measurement’ in the ‘Title, Abstract, Keywords’ field. A further search was performed using the terms ‘femoroacetabular’ or ‘impingement’. The search was limited to recent literature only. Results\textbf{Results} A total of 29 articles were reviewed to obtain information on a number of variables. These comprised the type of device used for measurement, rater standardisation, the type of movements tested, body positioning and comparative studies of muscle strength in FAI versus\textit{versus} normal controls. The studies found that hip muscle strength is lower in patients with FAI; this is also true for the asymptomatic hip in patients with FAI. Conclusions\textbf{Conclusions} Current literature on this subject is limited and examines multiple variables. Our recommendations for achieving reproducible results include stabilising the patient, measuring isometric movements and maximising standardisation by using a single tester and familiarising the participants with the protocol. Further work must be done to demonstrate the reliability of any new testing method

    Examining different aspects of functional performance using a variety of bench throw techniques

    No full text
    Examining different aspects of functional performance using a variety of bench throw techniques. The purpose of this experiment was to examine upper-body bench throw performance during tests that specifically target different aspects of functional performance. A pool of 26 male, semi-professional rugby league players (age: 23 ± 3 years, height: 180.8 ± 5.6 cm, mass: 95.7 ± 13.0 kg, estimated 1 repetition maximum bench press: 130 ± 20 kg) volunteered to participate in this study, which consisted of 2 components. First, the reliability of peak force (f) and displacement (d) measured during 4 different types of bench throws was assessed. These tests consisted of full range of motion (ROM) countermovement throws (FC), full ROM static start throws (FS), half ROM countermovement throws (HC), and half ROM static start throws (HS). For all measures, intraclass correlation coefficients were >0.80. The second component of this study examined the relationship between all measures, with a focus on the 2 simplest protocols to implement in an athlete assessment setting-FC and FS. A Pearson's correlation matrix revealed that a combination of FSd and FSf measures was moderately to highly correlated with all outcome measures, whereas neither FCd nor FCf was significantly correlated with HSf-a measure of the athlete's ability to produce force in the midrange of the movement with minimal elastic energy contribution. The results of this study suggest that, in situations where time efficiency is important, assessing full ROM bench throws from a static start may provide a representative measure of both upper-body full and partial ROM performance

    Test-Retest Reliability of the Stair Test in Patients with Total Hip Arthroplasty

    No full text
    Purpose: Stair climbing is one of the important functional activities of daily living to maintain mobility and independence. Walking and stair climbing have been identified by clinicians and patients as critical functional activities before and after total hip arthroplasty (THA). Testing the ability to manage steps has been commonly used in clinical and research settings because it is an inexpensive and simple way to measure functional status after THA. The frequent use of this test supports studies seeking evidence to validate stair test (ST) as a measure of physical performance in subjects with THA. The aim of this study is to determine the test-retest reliability of the 9-step ST in patients with THA

    The avoidance model in knee and hip osteoarthritis: a systematic review of the evidence

    No full text
    The avoidance model in patients with knee and hip osteoarthritis (OA) hypothesizes that pain and psychological distress lead to avoidance of activities, and thereby to muscle weakness and activity limitations. This paper systematically reviews the scientific evidence for the validity of this avoidance model. A qualitative data synthesis was used to identify levels of evidence. Sixty studies were included. In knee OA, strong evidence was found that avoidance of activities is associated with activity limitations via muscle weakness (mediation by muscle weakness), strong evidence was found for an association between muscle weakness and activity limitations, and weak evidence was found that pain and psychological distress are associated with muscle weakness via avoidance of activities (mediation by avoidance). In hip OA, weak evidence was found for mediation by muscle weakness; and strong evidence was found for an association between muscle weakness and activity limitations. More research is needed on the consecutive associations between pain or psychological distress, avoidance of activities and muscle weakness, and to confirm causal relationships
    • …
    corecore