1,392 research outputs found
Large-Area Scintillator Hodoscope with 50 ps Timing Resolution Onboard BESS
We describe the design and performance of a large-area scintillator hodoscope
onboard the BESS rigidity spectrometer; an instrument with an acceptance of 0.3
m^{2}sr.
The hodoscope is configured such that 10 and 12 counters are respectively
situated in upper and lower layers.
Each counter is viewed from its ends by 2.5 inch fine-mesh photomultiplier
tubes placed in a stray magnetic field of 0.2 Tesla.
Various beam-test data are presented.
Use of cosmic-ray muons at ground-level confirmed 50 ps timing resolution for
each layer, giving an overall time-of-flight resolution of 70 ps rms using a
pure Gaussian resolution function.
Comparison with previous measurements on a similar scintillator hodoscope
indicates good agreement with the scaling law that timing resolution is
proportional to 1/, where is the effective
number of photoelectrons.Comment: 16 pages, 14 figure
A search for massive neutral bosons in orthopositronium decay
We have searched for an exotic decay of orthopositronium into a single photon
and a short-lived neutral boson in the hitherto unexplored mass region above
900 , by noting that this decay is one of few remaining
candidates which could explain the discrepancy of the orthopositronium
decay-rate. A high-resolution measurement of the associated photon energy
spectrum was carried out with a germanium detector to search for a sharp peak
from this two-body decay. Our negative result provides the upper-limits
of\mbox{ } on the branching ratio of such a decay in the
mass region from 847 to 1013 , and excludes the
possibility of this decay mode explaining the discrepancy in the
orthopositronium decay-rate.Comment: a LaTeX file (text 7 pages) and a uuencoded gz-compressed PostScript
file (text 7 pages + figures 4 pages
Development of a Large-Area Aerogel Cherenkov Counter Onboard BESS
This paper describes the development of a threshold type aerogel Cherenkov
counter with a large sensitive area of 0.6 m to be carried onboard the BESS
rigidity spectrometer to detect cosmic-ray antiprotons. The design incorporates
a large diffusion box containing 46 finemesh photomultipliers, with special
attention being paid to achieving good performance under a magnetic field and
providing sufficient endurance while minimizing material usage. The refractive
index of the aerogel was chosen to be 1.03. By utilizing the muons and protons
accumulated during the cosmic-ray measurements at sea level, a rejection factor
of 10 was obtained against muons with , while keeping 97%
efficiency for protons below the threshold.Comment: 13 pages, LaTex, 9 eps figures included, submitted to NIM
Development of an advanced Compton camera with gaseous TPC and scintillator
A prototype of the MeV gamma-ray imaging camera based on the full
reconstruction of the Compton process has been developed. This camera consists
of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and
scintillation cameras. With the information of the recoil electrons and the
scattered gamma-rays, this camera detects the energy and incident direction of
each incident gamma-ray. We developed a prototype of the MeV gamma-ray camera
with a micro-TPC and a NaI(Tl) scintillator, and succeeded in reconstructing
the gamma-rays from 0.3 MeV to 1.3 MeV. Measured angular resolutions of ARM
(Angular Resolution Measure) and SPD (Scatter Plane Deviation) for 356 keV
gamma-rays were and , respectively.Comment: 4 pages, 5 figures. Proceedings of the 6th International Workshop On
Radiation Imaging Detector
Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays
We have studied the performance of two different types of front-end systems
for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels
multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64
pixels of which corresponds to the anode pixels of
H8500. One of the system is based on commercial ASIC chips in order to readout
every anode. The others are based on resistive charge divider network between
anodes to reduce readout channels. In both systems, each pixel (6mm) was
clearly resolved by flood field irradiation of Cs. We also investigated
the energy resolution of these systems and showed the performance of the
cascade connection of resistive network between some PMTs for large area
detectors.Comment: 9 pages, 6 figures, proceedings of the 7th International Workshop on
Radiation Imaging Detectors (IWORID7), submitted to NIM
- âŠ