55,199 research outputs found
Numerical simulation of two-phase cross flow in the gas diffusion layer microstructure of proton exchange membrane fuel cells
The cross flow in the under-land gas diffusion layer (GDL) between 2 adjacent channels plays an important role on water transport in proton exchange membrane fuel cell. A 3-dimensional (3D) two-phase model that is based on volume of fluid is developed to study the liquid water-air cross flow within the GDL between 2 adjacent channels. By considering the detailed GDL microstructures, various types of air-water cross flows are investigated by 3D numerical simulation. Liquid water at 4 locations is studied, including droplets at the GDL surface and liquid at the GDL-catalyst layer interface. It is found that the water droplet at the higher-pressure channel corner is easier to be removed by cross flow compared with droplets at other locations. Large pressure difference Îp facilitates the faster water removal from the higher-pressure channel. The contact angle of the GDL fiber is the key parameter that determines the cross flow of the droplet in the higher-pressure channel. It is observed that the droplet in the higher-pressure channel is difficult to flow through the hydrophobic GDL. Numerical simulations are also performed to investigate the water emerging process from different pores of the GDL bottom. It is found that the amount of liquid water removed by cross flow mainly depends on the pore's location, and the water under the land is removed entirely into the lower-pressure channel by cross flow
Analytical considerations of flow boiling heat transfer in metal-foam filled tubes
Flow boiling in metal-foam filled tube was analytically investigated based on a modified microstructure model, an original boiling heat transfer model and fin analysis for metal foams. Microstructure model of metal foams was established, by which fiber diameter and surface area density were precisely predicted. The heat transfer model for flow boiling in metal foams was based on annular pattern, in which two phase fluid was composed by vapor region in the center of the tube and liquid region near the wall. However, it was assumed that nucleate boiling performed only in the liquid region. Fin analysis and heat transfer network for metal foams were integrated to obtain the convective heat transfer coefficient at interface. The analytical solution was verified by its good agreement with experimental data. The parametric study on heat transfer coefficient and boiling mechanism was also carried out
Reduction of -Regular Noncrossing Partitions
In this paper, we present a reduction algorithm which transforms -regular
partitions of to -regular partitions of .
We show that this algorithm preserves the noncrossing property. This yields a
simple explanation of an identity due to Simion-Ullman and Klazar in connection
with enumeration problems on noncrossing partitions and RNA secondary
structures. For ordinary noncrossing partitions, the reduction algorithm leads
to a representation of noncrossing partitions in terms of independent arcs and
loops, as well as an identity of Simion and Ullman which expresses the Narayana
numbers in terms of the Catalan numbers
A multi-view approach to cDNA micro-array analysis
The official published version can be obtained from the link below.Microarray has emerged as a powerful technology that enables biologists to study thousands of genes simultaneously, therefore, to obtain a better understanding of the gene interaction and regulation mechanisms. This paper is concerned with improving the processes involved in the analysis of microarray image data. The main focus is to clarify an image's feature space in an unsupervised manner. In this paper, the Image Transformation Engine (ITE), combined with different filters, is investigated. The proposed methods are applied to a set of real-world cDNA images. The MatCNN toolbox is used during the segmentation process. Quantitative comparisons between different filters are carried out. It is shown that the CLD filter is the best one to be applied with the ITE.This work was supported in part by the Engineering and Physical Sciences Research
Council (EPSRC) of the UK under Grant GR/S27658/01, the National Science Foundation of China under Innovative Grant 70621001, Chinese Academy of Sciences
under Innovative Group Overseas Partnership Grant, the BHP Billiton Cooperation of Australia Grant, the International Science and Technology Cooperation Project of China
under Grant 2009DFA32050 and the Alexander von Humboldt Foundation of Germany
Acoustic detection of air shower cores
At an altitude of 1890m, a pre-test with an Air shower (AS) core selector and a small acoustic array set up in an anechoic pool with a volume of 20x7x7 cu m was performed, beginning in Aug. 1984. In analyzing the waveforms recorded during the effective working time of 186 hrs, three acoustic signals which cannot be explained as from any source other than AS cores were obtained, and an estimation of related parameters was made
- âŠ