3,571 research outputs found

    Radiation Damage and Recovery Properties of Common Plastics PEN (Polyethylene Naphthalate) and PET (Polyethylene Terephthalate) Using a 137Cs Gamma Ray Source Up To 1 MRad and 10 MRad

    Full text link
    Polyethylene naphthalate (PEN) and polyethylene teraphthalate (PET) are cheap and common polyester plastics used throughout the world in the manufacturing of bottled drinks, containers for foodstuffs, and fibers used in clothing. These plastics are also known organic scintillators with very good scintillation properties. As particle physics experiments increase in energy and particle flux density, so does radiation exposure to detector materials. It is therefore important that scintillators be tested for radiation tolerance at these generally unheard of doses. We tested samples of PEN and PET using laser stimulated emission on separate tiles exposed to 1 MRad and 10 MRad gamma rays with a 137Cs source. PEN exposed to 1 MRad and 10 MRad emit 71.4% and 46.7% of the light of an undamaged tile, respectively, and maximally recover to 85.9% and 79.5% after 5 and 9 days, respectively. PET exposed to 1 MRad and 10 MRad emit 35.0% and 12.2% light, respectively, and maximally recover to 93.5% and 80.0% after 22 and 60 days, respectively

    Radiation-Hard Quartz Cerenkov Calorimeters

    Get PDF
    New generation hadron colliders are going to reach unprecedented energies and radiation levels. Quartz has been identified as a radiation-hard material that can be used for Cerenkov calorimeters of the future experiments. We report from the radiation hardness tests performed on quartz fibers, as well as the characteristics of the quartz fiber and plate Cerenkov calorimeters that have been built, designed, and proposed for the CMS experiment

    Status of Zero Degree Calorimeter for CMS Experiment

    Get PDF
    The Zero Degree Calorimeter (ZDC) is integral part of the CMS experiment, especially, for heavy ion studies. The design of the ZDC includes two independent calorimeter sections: an electromagnetic section and a hadronic section. Sampling calorimeters using tungsten and quartz fibers have been chosen for the energy measurements. An overview of the ZDC is presented along with a current status of calorimeter's preparation for Day 1 of LHC.Comment: 8 pages, 5 figures, 1 table, to appear in the proceedings of CALOR06, June 5-9, 2006 Chicago, US

    Tests of a Novel Design of Resistive Plate Chambers

    Full text link
    A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The tests confirmed the viability of this new approach. In addition to showing an improved single-particle response compared to the traditional 2-plate design, the novel chambers also prove to be suitable for calorimetric applications

    Characterization of photomultiplier tubes in a novel operation mode for Secondary Emission Ionization Calorimetry

    Full text link
    Hamamatsu single anode R7761 and multi-anode R5900-00-M16 Photomultiplier Tubes have been characterized for use in a Secondary Emission (SE) Ionization Calorimetry study. SE Ionization Calorimetry is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The different operation modes used in these tests were developed by modifying the conventional PMT bias circuit. These modifications were simple changes to the arrangement of the voltage dividers of the baseboard circuits. The PMTs with modified bases, referred to as operating in SE mode, are used as an SE detector module in an SE calorimeter prototype, and placed between absorber materials (Fe, Cu, Pb, W, etc.). Here, the technical design of different operation modes, as well as the characterization measurements of both SE modes and the conventional PMT mode are reported

    Physics at Very Small Angles with CASTOR at CMS

    Get PDF
    CASTOR is a small (56 cm diameter) quartz-tungsten Cerenkov calorimeter covering the small angles 0.2-0.6 deg (5.2<="eta"<=6.4) in CMS, a major experiment at the LHC. Particularly with heavy-ion reactions a substantial fraction of the total reaction energy goes into this large "eta" region. CASTOR will function as a part of CMS and also as an independent detector to search for special types of events in the far-forward region. It is divided into 16 azimuthal sectors, each with 18 longitudinal segments to allow identification of particles by their energy-loss profiles. The most forward segments are smaller to better characterize electromagnetic events

    Status of zero degree calorimeter for CMS experiment

    Get PDF
    The Zero Degree Calorimeter (ZDC) is integral part of the CMS experiment, especially, for heavy ion studies. The design of the ZDC includes two independent calorimeter sections: an electromagnetic section and a hadronic section. Sampling calorimeters using tungsten and quartz fibers have been chosen for the energy measurements. An overview of the ZDC is presented along with a current status of calorimeter's preparation for Day 1 of LHC

    Research of Purchasing Management of C Shipbuilding Company

    Get PDF
    船舶制造行业,从2002年的蓬勃发展到2008年受金融危机影响至今的持续低迷,使得当前船舶制造行业面临着前所未有的巨大挑战,接单难、交船难、融资难成为船舶行业普遍的现象。如何生存下去成为当今我国船舶制造业极力需要解决的难题,而采购作为船舶行业发生成本最大的领域,充分挖掘采购作为企业的第三利润源泉的作用,对于降低成本,提高企业的竞争地位有着重大的战略意义,对此的研究也具有重大实际意义。 本论文从C船舶制造企业网络比价议标的采购模式分析入手,对这一新型采购管理模式进行了探索和研究。通过在C船企实际工作和大量调查,分析归纳C船企当前采购管理所存在的一些问题,并通过SWOT分析工具对C船企采购管理的...The shipbuilding industry was rapidly developed from 2002 to 2008, but remains downturn up to now by the financial crisis. So the current shipbuilding industry is facing many unprecedented challenges, such as the difficulty of the order, the difficulty of delivery of ship and financing become common phenomenon in the shipbuilding industry. Nowadays, How to survive is become a big problem, which ne...学位:管理学硕士院系专业:管理学院企业管理系_企业管理(含财务管理、市场营销、人力资源管理)学号:20071401

    Quartz Plate Calorimeter as SLHC Upgrade to CMS Hadronic EndCap Calorimeters

    Get PDF
    Due to an expected increase in radiation damage under super-LHC conditions, we propose to substitute the scintillator tiles in the original design of the hadronic endcap (HE) calorimeter with quartz plates. Quartz is proved to be radiation hard by the radiation damage tests with electron, proton, neutron and gamma beams. Using wavelength shifting fibers, it is possible to collect efficiently the Cherenkov light generated in quartz plates. This paper summarizes the results from various test beams, bench tests, and Geant4 simulations done on methods of collecting light from quartz plates, as well as radiation hardness tests on quartz material

    Performance of the combined zero degree calorimeter for CMS

    Get PDF
    The combined zero degree calorimeter (ZDC) is a combination of sampling quartz/tungsten electromagnetic and hadronic calorimeters. Two identical combined calorimeters are located in the LHC tunnel at CERN at the straight section 140 m on each side of the CMS interaction vertex and between the two beam pipes. They will detect very forward photons and neutrons. ZDC information can be used for a variety of physics measurements as well as improving the collision centrality determination in heavy-ion collisions. Results are presented for ZDC performance studies with the CERN SPS H2 test beam.The combined zero degree calorimeter (ZDC) is a combination of sampling quartz/tungsten electromagnetic and hadronic calorimeters. Two identical combined calorimeters are located in the LHC tunnel at CERN at the straight section ~140 m on each side of the CMS interaction vertex and between the two beam pipes. They will detect very forward photons and neutrons. ZDC information can be used for a variety of physics measurements as well as improving the collision centrality determination in heavy-ion collisions. Results are presented for ZDC performance studies with the CERN SPS H2 test beam
    corecore