1,780 research outputs found

    Investigation and prediction of slug flow characteristics in highly viscous liquid and gas flows in horizontal pipes

    Get PDF
    Slug flow characteristics in highly viscous liquid and gas flow are studied experimentally in a horizontal pipe with 0.074 m ID and 17 m length. Results of flow regime map, liquid holdup and pressure gradient are discussed and liquid viscosity effects are investigated. Applicable correlations which are developed to predict liquid holdup in slug body for low viscosity flow are assessed with high viscosity liquids. Furthermore, a mechanistic model is developed for predicting the characteristics of slug flows of highly viscous liquid in horizontal pipes. A control volume is drawn around the slug body and slug film in a slug unit. Momentum equations with a momentum source term representing the significant momentum exchange between film zone and slug body are applied. Liquid viscosity effects are considered in closure relations. The mechanistic model is validated by comparing available pressure gradient and mean slug liquid holdup data produced in the present study and those obtained from literature, showing satisfactory capabilities over a large range of liquid viscosity

    Mid-infrared photodetectors operating over an extended wavelength range up to 90 K

    Get PDF
    We report a wavelength threshold extension, from the designed value of 3.1 to 8.9 μm, in a -type heterostructure photodetector. This is associated with the use of a graded barrier and barrier offset, and arises from hole–hole interactions in the detector absorber. Experiments show that using long-pass filters to tune the energies of incident photons gives rise to changes in the intensity of the response. This demonstrates an alternative approach to achieving tuning of the photodetector response without the need to adjust the characteristic energy that is determined by the band structure

    Pressure-stabilized tin selenide phase with an unexpected stoichiometry and a predicted superconducting state at low temperatures

    Get PDF
    published_or_final_versio

    Comparison of chemical profiles and effectiveness between Erxian decoction and mixtures of decoctions of its individual herbs : a novel approach for identification of the standard chemicals

    Get PDF
    Acknowledgements This study was partially supported by grants from the Seed Funding Programme for Basic Research (Project Number 201211159146 and 201411159213), the University of Hong Kong. We thank Mr Keith Wong and Ms Cindy Lee for their technical assistances.Peer reviewedPublisher PD

    Corticosterone mediates electroacupuncture-produced anti-edema in a rat model of inflammation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Electroacupuncture (EA) has been reported to produce anti-edema and anti-hyperalgesia effects on inflammatory disease. However, the mechanisms are not clear. The present study investigated the biochemical mechanisms of EA anti-inflammation in a rat model.</p> <p>Methods</p> <p>Three experiments were conducted on male Sprague-Dawley rats (n = 7–8/per group). Inflammation was induced by injecting complete Freund's adjuvant (CFA) subcutaneously into the plantar surface of one hind paw. Experiment 1 measured plasma corticosterone (CORT) levels to see if EA regulates CORT secretion. Experiment 2 studied the effects of the adrenal gland on the therapeutic actions of EA using adrenalectomy (ADX) rats. Experiment 3 determined whether a prototypical glucocorticoid receptor antagonist, RU486, affects EA anti-edema. EA treatment, 10 Hz at 3 mA and 0.1 ms pulse width, was given twice, for 20 min each, once immediately after CFA administration and again 2 h post-CFA. Plasma CORT levels, paw thickness, indicative of the intensity of inflammation, and paw withdrawal latency (PWL) were measured 2 h and 5 h after the CFA injection.</p> <p>Results</p> <p>EA significantly increased plasma corticosterone levels 2 h (5 folds) and 5 h (10 folds) after CFA administration compared to sham EA control, but EA alone in naive rats and CFA alone did not induce significant increases in corticosterone. Adrenalectomy blocked EA-produced anti-edema, but not EA anti-hyperalgesia. RU486 (15 μl, 15 μg/μl), a prototypical glucocorticoid receptor antagonist, also prevented EA anti-edema.</p> <p>Conclusion</p> <p>The data demonstrate that EA activates the adrenals to increase plasma corticosterone levels and suppress edema and suggest that EA effects differ in healthy subjects and in those with pathologies.</p

    Modified Huo-Luo-Xiao-Ling Dan Suppresses Adjuvant Arthritis by Inhibiting Chemokines and Matrix-Degrading Enzymes

    Get PDF
    Rheumatoid arthritis (RA) is a chronic inflammatory disease affecting the joints that can lead to deformities and disability. The prolonged use of conventionally used drugs is associated with severe adverse reactions. Therefore, safer and less expensive therapeutic products are continually being sought. Huo-Luo-Xiao-Ling dan (HLXL), a traditional Chinese herbal mixture, and its modified versions possess anti-arthritic activity. In this paper, we examined the influence of modified HLXL on two of the key mediators of arthritic inflammation and tissue damage, namely, chemokines and matrix-metalloproteinases (MMPs) in the rat adjuvant-induced arthritis (AA) model of RA. We treated arthritic Lewis rats with HLXL (2.3 g/kg) by daily gavage beginning at the onset of AA. The control rats received the vehicle. At the peak phase of AA, rats were sacrificed and their draining lymph node cells (LNC) and spleen adherent cells (SAC) were tested. The HLXL-treated rats showed a significant reduction in the levels of chemokines (RANTES, MCP-1, MIP-1α, and GRO/KC), MMPs (MMP 2 and 9), as well as cytokines (IL-6 and IL-17) that induce them, compared to the control vehicle-treated rats. Thus, HLXL controls arthritis in part by suppressing the mediators of immune pathology, and it might offer a promising alternative/adjunct treatment for RA
    corecore