1,810 research outputs found

    Pseudo-Hall effect and anisotropic magnetoresistance in a micronscale Ni80Fe20 device

    Get PDF
    The pseudo-Hall effect (PHE) and anisotropic magnetoresistance (AMR) in a micronscale Ni80Fe20, six-terminal device, fabricated by optical lithography and wet chemical etching from a high quality UHV grown 30 Angstrom Au/300 Angstrom Ni80Fe20 film, have been studied. The magnetisation reversal in different parts of the device has been measured using magneto-optical Kerr effect (MOKE), The device gives a 50% change in PHE voltage with an ultrahigh sensitivity of 7.3%Oe(-1) at room temperature. The correlation between the magnetisation, magneto-transport properties, lateral shape of the device and directions of the external applied field is discussed based on extensive MOKE, AMR and PHE results

    Influence of lateral geometry on magnetoresistance and magnetisation reversal in Ni80Fe20 wires

    Get PDF
    The magnetisation reversal processes and magnetoresistance behaviour in micron-sized Ni80Fe20 wires with triangular and rectangular modulated width have been studied. The wires were fabricated by electron beam lithography and a lift-off process. A combination of magnetic force microscopy (MFM), magneto-optical Kerr effect (MOKE) and magnetoresistance (MR) measurements shows that the lateral geometry of the wires greatly influences the magnetic and transport properties. The width modulations modify not only the shape-dependent demagnetising fields, but also the current density. The correlation between the lateral geometry, the magnetic and the transport properties is discussed based on MFM, MOKE and MR results

    Acoustic noise radiated by PWM-controlled induction machine drives

    Get PDF
    This paper investigates the acoustic noise radiated from two nominally identical induction motors when fed from sinusoidal, and asymmetric regular sampling subharmonic and space-vector pulsewidth modulation (PWM) converters. The theory for analyzing the noise spectrum is developed further to account for the interaction between the motor and the drive. It is shown that manufacturing tolerances can result in significant differences in the noise level emitted from nominally identical motors, and that mechanical resonances can result in extremely high noise emissions. Such resonances can be induced by stator and rotor slot air-gap field harmonics due to the fundamental component of current, and by the interaction between the airgap field harmonics produced by the fundamental and the PWM harmonic currents. The significance of the effect of PWM strategy on the noise is closely related to the mechanical resonance with vibration mode order zero, while the PWM strategy will be critical only if the dominant cause of the emitted noise is the interaction of the fundamental air-gap field and PWM harmonic

    Magnetic domain studies of permalloy wire-based structures with junctions

    Get PDF
    Permalloy (Ni-80 Fe-20) wire-based structures (30 nm thick and 1 . w . 10 mum wide) with junctions (crosses, networks, H-shapes, rectangular chains and ring chains) prepared on a GaAs (100) substrate were observed in both their demagnetized and remanent states by magnetic force microscopy (MFM) in order to investigate the role of junction geometry in domain formation, Except in ring chains, two classes of domain configuration are found at the junction: (i) a domain wall-like feature due to abrupt spin rotation and (ii) a triangle-shape domain consistent with a flux closure configuration, Ring chains, on the other hand, form vortex domains at every other junction. The MFM observations are compared with micromagnetic calculations which qualitatively support the magnetic domain configurations

    Magnetic domain evolution in permalloy mesoscopic dots

    Get PDF
    Permalloy (Ni80Fe20) squares (30 nm thick and w mu m wide; 1 less than or equal to w less than or equal to 200 mu m) and circular disks (30 nm thick and r mu m diameter; 1 less than or equal to r less than or equal to 200 mu m) prepared on a GaAs (100) substrate were observed in both their demagnetized and remanent states by magnetic force microscopy (MFM) associated with non-contact atomic force microscopy (NC-AFM). The squares (2 less than or equal to w mu m) exhibited conventional closure domains and the corner plays a very important role in creating new walls. The circular disks, on the other hand, formed either vortex domain (5 less than or equal to r less than or equal to 20 mu m) or multi-domain (50 less than or equal to r mu m) states, The magnetization rotation is observed by MFM to change according to the size and shape of the elements, The MFM observations are supported by micromagnetic calculations which confirm the effect of the corner on the domain wall formation

    Magnetization reversal in mesoscopic Ni80Fe20 wires: A magnetic domain launching device

    Get PDF
    The magnetization reversal process in mesoscopic permalloy (Ni80Fe20) wire structures has been investigated using scanning Kerr microscopy, magnetic force microscopy (MFM) and micromagnetic calculations. We find that the junction offers a site for reversed domain wall nucleation in the narrow part of the wires. As a consequence, the switching field is dominated by the domain nucleation field and the junction region initiates reversal by the wall motion following the nucleation of domains. Our results suggest the possibility of designing structures that can be used to “launch” reverse domains in narrow wires within a controlled field rang

    Key-point Detection based Fast CU Decision for HEVC Intra Encoding

    Get PDF
    As the most recent video coding standard, High Efficiency Video Coding (HEVC) adopts various novel techniques, including a quad-tree based coding unit (CU) structure and additional angular modes used for intra encoding. These newtechniques achieve a notable improvement in coding efficiency at the penalty of significant computational complexity increase. Thus, a fast HEVC coding algorithm is highly desirable. In this paper, we propose a fast intra CU decision algorithm for HEVC to reduce the coding complexity, mainly based on a key-point detection. A CU block is considered to have multiple gradients and is early split if corner points are detected inside the block. On the other hand, a CU block without corner points is treated to be terminated when its RD cost is also small according to statistics of the previous frames. The proposed fast algorithm achieves over 62% encoding time reduction with 3.66%, 2.82%, and 2.53% BD-Rate loss for Y, U, and V components, averagely. The experimental results show that the proposed method is efficient to fast decide CU size in HEVC intra coding, even though only static parameters are applied to all test sequences

    Magnetization reversal and magnetic anisotropy in Co network nanostructures

    Get PDF
    The magnetization reversal and magnetic anisotropy in Co network structures have been studied using magneto-optic Kerr effect (MOKE). An enhancement of the coercivity is observed in the network structures and is attributed to the pinning of domain walls by the hole edges in the vicinity of which the demagnetizing field spatially varies. We find that the magnetization reversal process is dominated by the intrinsic unaxial anisotropy (2K(u)/M(s)approximate to 200 Oe) in spite of the shape anisotropy induced by the hole edges. The influence of the cross-junction on the competition between the intrinsic uniaxial anisotropy and the induced shape anisotropy is discussed using micromagnetic simulations

    Loading a vapor cell magneto-optic trap using light-induced atom desorption

    Get PDF
    Low intensity white light was used to increase the loading rate of 87^{87}Rb atoms into a vapor cell magneto-optic trap by inducing non-thermal desorption of Rb atoms from the stainless steel walls of the vapor cell. An increased Rb partial pressure reached a new equilibrium value in less than 10 seconds after switching on the broadband light source. After the source was turned off, the partial pressure returned to its previous value in 1/e1/e times as short as 10 seconds.Comment: 7 pages, 6 figure

    A possible cooling effect in high temperature superconductors

    Full text link
    We show that an adiabatic increase of the supercurrent along a superconductor with lines of nodes of the order parameter on the Fermi surface can result in a cooling effect. The maximum cooling occurs if the supercurrent increases up to its critical value. The effect can also be observed in a mixed state of a bulk sample. An estimate of the energy dissipation shows that substantial cooling can be performed during a reasonable time even in the microkelvin regime.Comment: 5 pages, to appear in Phys. Rev.
    corecore