954 research outputs found

    Formation and migration of vacancy defects in GeSe and SnSe

    Get PDF
    The GeSe and SnSe have great potential in nuclear detector devices. Under irradiation, the formation and migration of point defects may affect their properties and performance significantly. In this study, a comparative study of vacancy formation and migration in GeSe and SnSe has been carried out by a first-principles method. It is shown that in both compounds the cation vacancies are generally much easier to form than anion vacancies, and the cation vacancies are generally easier to migrate than anion vacancies. For both Ge vacancy and Sn vacancy, the migration is anisotropic and the [322] direction is the most favorable migration pathway. The migration energy barrier are 0.54 eV for Ge vacancy and 0.46–0.52 eV for Sn vacancy, suggesting that vacancy clusters are relatively easy to form in both compounds, which may influence the application of GeSe and SnSe in nuclear detector devices

    Alternative antibody for the detection of CA19-9 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access (R) GI Monitor assay on the UniCel (R) Dxl 800 Immunoassay System

    Get PDF
    Background: Gastrointestinal cancer antigen CA19-9 is known as a valuable marker for the management of patients with pancreatic cancer. Methods: The analytical and clinical performance of the Access(R) GI Monitor assay (Beckman Coulter) was evaluated on the UniCel(R) Dxl 800 Immunoassay System at five different European sites and compared with a reference method, defined as CA19-9 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the GI Monitor ranged between 3.4% and 7.7%, and inter-laboratory reproducibility between 3.6% and 4.0%. Linearity upon dilution showed a mean recovery of 97.4% (SD+7.2%). Endogenous interferents had no influence on GI Monitor levels (mean recoveries: hemoglobin 103%, bilirubin 106%, triglycerides 106%). There was no high-dose hook effect up to 115,000 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access' GI Monitor and Elecsys CA19-9 (R = 0.959, slope = 1.004, intercept +0.17). GI Monitor serum levels were low in healthy individuals (n = 267, median = 6.0 kU/L, 95th percentile = 23.1 kU/L), higher in individuals with various benign diseases (n = 550, medians = 5.8-13.4 kU/L, 95th percentiles = 30.1-195.5 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 8.4-233.8 kU/L, 95th percentiles = 53.7-13,902 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the GI Monitor was found for pancreatic cancer {[}area under the curve (AUC) 0.83]. Results for the reference CA19-9 assay were comparable (AUC 0.85). Conclusions: The Access(R) GI Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with the Elecsys CA19-9. The GI Monitor shows the best diagnostic accuracy in pancreatic cancer. Our results also suggest a clinical value of the GI Monitor in other cancers

    Effect of gas volume fraction on vortex motion in hydraulic turbine

    Get PDF
    In order to analyze the vortex motion in the flow channel of the hydraulic turbine impeller during the gas volume fraction change. Now, the pump with a specific speed of 55.7 is chosen as hydraulic turbine. On the basis of considering the gas compressibility, to take numerical calculation on the model under different flow rates and different gas volume fraction, to analyze the influence of gas volume fraction on vortex motion law in the impeller flow channel. Findings: When the flow rate is small, the relative velocity distribution in the impeller flow channel is uneven, the velocity field is chaotic, and there are obvious vortices, with the increase of the gas volume fraction, the vortices in the impeller flow channel gradually move to the inlet direction of the blade; With the increase of the flow rate, the flow in the channel of the hydraulic turbine impeller is unstable. Both the pressure surface and the suction surface of the blade appear vortices, the vortex region in the impeller flow channel is enlarged, and all of them are concentrated on the back of the blade. The results provide a theoretical basis for the optimal design of hydraulic turbine structures

    Prognostic and therapeutic significance of carbohydrate antigen 19-9 as tumor marker in patients with pancreatic cancer

    Get PDF
    In pancreatic cancer ( PC) accurate determination of treatment response by imaging often remains difficult. Various efforts have been undertaken to investigate new factors which may serve as more appropriate surrogate parameters of treatment efficacy. This review focuses on the role of carbohydrate antigen 19- 9 ( CA 19- 9) as a prognostic tumor marker in PC and summarizes its contribution to monitoring treatment efficacy. We undertook a Medline/ PubMed literature search to identify relevant trials that had analyzed the prognostic impact of CA 19- 9 in patients treated with surgery, chemoradiotherapy and chemotherapy for PC. Additionally, relevant abstract publications from scientific meetings were included. In advanced PC, pretreatment CA 19- 9 levels have a prognostic impact regarding overall survival. Also a CA 19- 9 decline under chemotherapy can provide prognostic information for median survival. A 20% reduction of CA 19- 9 baseline levels within the first 8 weeks of chemotherapy appears to be sufficient to define a prognostic relevant subgroup of patients ('CA 19- 9 responder'). It still remains to be defined whether the CA 19- 9 response is a more reliable method for evaluating treatment efficacy compared to conventional imaging. Copyright (c) 2006 S. Karger AG, Basel

    Resonances in J/ψ→ϕπ+π−J/\psi \to \phi \pi ^+\pi ^- and ϕK+K−\phi K^+K^-

    Full text link
    A partial wave analysis is presented of J/ψ→ϕπ+π−J/\psi \to \phi \pi ^+\pi ^- and ϕK+K−\phi K^+K^- from a sample of 58M J/ψJ/\psi events in the BES II detector. The f0(980)f_0(980) is observed clearly in both sets of data, and parameters of the Flatt\' e formula are determined accurately: M=965±8M = 965 \pm 8 (stat) ±6\pm 6 (syst) MeV/c2^2, g1=165±10±15g_1 = 165 \pm 10 \pm 15 MeV/c2^2, g2/g1=4.21±0.25±0.21g_2/g_1 = 4.21 \pm 0.25 \pm 0.21. The ϕππ\phi \pi \pi data also exhibit a strong ππ\pi \pi peak centred at M=1335M = 1335 MeV/c2^2. It may be fitted with f2(1270)f_2(1270) and a dominant 0+0^+ signal made from f0(1370)f_0(1370) interfering with a smaller f0(1500)f_0(1500) component. There is evidence that the f0(1370)f_0(1370) signal is resonant, from interference with f2(1270)f_2(1270). There is also a state in ππ\pi \pi with M=1790−30+40M = 1790 ^{+40}_{-30} MeV/c2^2 and Γ=270−30+60\Gamma = 270 ^{+60}_{-30} MeV/c2^2; spin 0 is preferred over spin 2. This state, f0(1790)f_0(1790), is distinct from f0(1710)f_0(1710). The ϕKKˉ\phi K\bar K data contain a strong peak due to f2′(1525)f_2'(1525). A shoulder on its upper side may be fitted by interference between f0(1500)f_0(1500) and f0(1710)f_0(1710).Comment: 17 pages, 6 figures, 1 table. Submitted to Phys. Lett.

    First Measurements of eta_c Decaying into K^+K^-2(pi^+pi^-) and 3(pi^+pi^-)

    Full text link
    The decays of eta_c to K^+K^-2(pi^+pi^-) and 3(pi^+pi^-) are observed for the first time using a sample of 5.8X10^7 J/\psi events collected by the BESII detector. The product branching fractions are determined to be B(J/\psi-->gamma eta_c)*B(eta_c-->K^+K^-pi^+pi^-pi^+pi^-)=(1.21+-0.32+- 0.23)X10^{-4},B(J/ψ−−>gammaetac)∗B(etac−−>K∗0Kˉ∗0pi+pi−)=(1.29+−0.43+−0.32)X10−4,B(J/\psi-->gamma eta_c)*B(eta_c-->K^{*0}\bar{K}^{*0}pi^+pi^-)= (1.29+-0.43+-0.32)X10^{-4}, and (J/\psi-->gamma eta_c)* B(eta_c-->pi^+pi^-pi^+pi^-pi^+pi^-)= (2.59+-0.32+-0.48)X10^{-4}. The upper limit for eta_c-->phi pi^+pi^-pi^+pi^- is also obtained as B(J/\psi-->gamma eta_c)*B(eta_c--> phi pi^+pi^-pi^+pi^-)< 6.03 X10^{-5} at the 90% confidence level.Comment: 11 pages, 4 figure

    Purification and preliminary characterization of a xylanase from Thermomyces lanuginosus strain SS-8

    Get PDF
    Thermomyces lanuginosus SS-8 was isolated from soil samples that had been collected from near self-heating plant material and its extracellular cellulase-free xylanase purified approximately 160-fold using ion exchange chromatography and continuous elution electrophoresis. This xylanase was thermoactive (optimum temperature 60 °C) at pH 6.0 and had a molecular weight of 23.79 kDa as indicated by SDS-PAGE electrophoresis. The xylanase rapidly hydrolyzed xylan directly to xylose without the production of intermediary xylo-oligosaccharides within 15 min of incubation under optimum conditions. This trait of rapidly degrading xylan to xylose as a sole end-product could have biotechnological potential in degradation of agro-wastes for bioethanol manufacturing industry

    Observation of a ppb mass threshoud enhancement in \psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) decay

    Full text link
    The decay channel ψ′→π+π−J/ψ(J/ψ→γppˉ)\psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) is studied using a sample of 1.06×1081.06\times 10^8 ψ′\psi^\prime events collected by the BESIII experiment at BEPCII. A strong enhancement at threshold is observed in the ppˉp\bar{p} invariant mass spectrum. The enhancement can be fit with an SS-wave Breit-Wigner resonance function with a resulting peak mass of M=1861−13+6(stat)−26+7(syst)MeV/c2M=1861^{+6}_{-13} {\rm (stat)}^{+7}_{-26} {\rm (syst)} {\rm MeV/}c^2 and a narrow width that is Γ<38MeV/c2\Gamma<38 {\rm MeV/}c^2 at the 90% confidence level. These results are consistent with published BESII results. These mass and width values do not match with those of any known meson resonance.Comment: 5 pages, 3 figures, submitted to Chinese Physics
    • …
    corecore