55 research outputs found

    A Measurement of Psi(2S) Resonance Parameters

    Full text link
    Cross sections for e+e- to hadons, pi+pi- J/Psi, and mu+mu- have been measured in the vicinity of the Psi(2S) resonance using the BESII detector operated at the BEPC. The Psi(2S) total width; partial widths to hadrons, pi+pi- J/Psi, muons; and corresponding branching fractions have been determined to be Gamma(total)= (264+-27) keV; Gamma(hadron)= (258+-26) keV, Gamma(mu)= (2.44+-0.21) keV, and Gamma(pi+pi- J/Psi)= (85+-8.7) keV; and Br(hadron)= (97.79+-0.15)%, Br(pi+pi- J/Psi)= (32+-1.4)%, Br(mu)= (0.93+-0.08)%, respectively.Comment: 8 pages, 6 figure

    Measurements of the Mass and Full-Width of the ηc\eta_c Meson

    Get PDF
    In a sample of 58 million J/ψJ/\psi events collected with the BES II detector, the process J/ψγηc\psi\to\gamma\eta_c is observed in five different decay channels: γK+Kπ+π\gamma K^+K^-\pi^+\pi^-, γπ+ππ+π\gamma\pi^+\pi^-\pi^+\pi^-, γK±KS0π\gamma K^\pm K^0_S \pi^\mp (with KS0π+πK^0_S\to\pi^+\pi^-), γϕϕ\gamma \phi\phi (with ϕK+K\phi\to K^+K^-) and γppˉ\gamma p\bar{p}. From a combined fit of all five channels, we determine the mass and full-width of ηc\eta_c to be mηc=2977.5±1.0(stat.)±1.2(syst.)m_{\eta_c}=2977.5\pm1.0 ({stat.})\pm1.2 ({syst.}) MeV/c2c^2 and Γηc=17.0±3.7(stat.)±7.4(syst.)\Gamma_{\eta_c} = 17.0\pm3.7 ({stat.})\pm7.4 ({syst.}) MeV/c2c^2.Comment: 9 pages, 2 figures and 4 table. Submitted to Phys. Lett.

    Psi(2S) two- and three-body hadronic decays

    Full text link
    We report measurements of branching fractions for psi(2S) decays into omega pi pi, b1 pi,omega f2(1270),omega KK, omega p pbar, phi pi pi, phi f0(980),phi KK, and an upper limit for phi p pbar final states based on a data sample of 4 X 10^6 psi(2S) events collected with the BESI detector at the Beijing Electron-Positron Collider. The branching fractions for b1 pi and omega f2(1270) update previous BES results, while those for other decay modes are first measurements. The ratios of psi(2S)and J/psi branching fractions are smaller than what is expected from the 12% rule by a factor of five for omega f2(1270),by a factor of two for omega pi pi, omega p pbar, and phi KK, while for other studied channels the ratios are consistent with expectation within errors.Comment: 9 pages,12 figures and 1 tabl

    ATLAS detector and physics performance: Technical Design Report, 1

    Get PDF

    Digital Curvelet Transform for Palmprint Recognition

    No full text

    Corrigendum: Stk38 Modulates Rbm24 Protein Stability to Regulate Sarcomere Assembly in Cardiomyocytes

    No full text
    10.1038/srep46854Scientific reports74685

    Stk38 Modulates Rbm24 Protein Stability to Regulate Sarcomere Assembly in Cardiomyocytes

    No full text
    10.1038/srep44870Scientific Reports74487
    corecore