9,048 research outputs found

    A novel phase-aligned analysis on motion patterns of table tennis strokes

    Get PDF
    © 2016, Routledge. All rights reserved. A wide range of human motion represent repetitive patterns particularly in racket sports. Quantitative analysis of the continuous variables during the different phases of the motion cycle helps to investigate more deeply the specific movement of the racket or player. Table tennis biomechanics research to date lacks the necessary detail of phase decomposition and phase-based quantitative analysis. Therefore, this study proposes a novel velocity-based piecewise alignment method to identify the different phases of a table tennis forehand stroke. A controlled experiment was conducted on a number of players of two differing ability levels (experts vs. novices) to implement this novel methodology. Detailed results are shown for the quantitative analysis on multiple strokes of the two groups of participants. Significant differences were found in both the displacement and velocity of the racket movement in the backswing, forward swing and follow-through phases. For example, it is clear that experts’ strokes show higher racket resultant velocity than novices during both the forward swing and follow-through phases by up to a factor of two. Furthermore, the phase-based approach to analysing racket motions leads to interrogation over a greater duration than the traditional time-based method which is generally only concerned with impact ±0.25s

    Shoulder joint angle errors caused by marker offset

    Get PDF
    Crown Copyright © 2015 Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license. The International Society of Biomechanics (ISB) has recommended a standardization of the definition of the joint coordinate system (JCS) and use of a sequential rotation to describe human shoulder joint rotation. Markers attached to the surface of the body may move during the process of motion data capture, resulting in an offset from their initial location. This leads to a change of the JCS and therefore affects the calculated shoulder joint angles. In this research study, we presented a simple marker offset model to quantify the shoulder joint errors for both static poses and dynamic activities. Specific conditions of different offsets and elbow flexion angles were studied. Results showed that the errors should not be neglected when the shoulder elevation angle was near -90° and 90°, or elbow flexion was very small. Attention should be paid to these errors for such activities especially walking and throwing

    Successful Pregnancy after Treatment with Chinese Herbal Medicine in a 43-Year-Old Woman with Diminished Ovarian Reserve and Multiple Uterus Fibrosis: A Case Report.

    Full text link
    OBJECTIVE: To highlight a natural approach to coexisting oligomenorrhea, subfertility, luteal phase insufficiency and multiple fibroids cohesively when in vitro fertilisation (IVF) has failed. CASE PRESENTATION: A 43-year-old woman with diminished ovarian reserve and multiple uterine fibroids had previously been advised to discontinue IVF treatment. According to Chinese Medicine diagnosis, herbal formulae were prescribed for improving age-related ovarian insufficiency as well as to control the growth of fibroids. After 4 months of treatment, the patient's menstrual cycle became regula r and plasma progesterone one week after ovulation increased from 10.9 nmol/L to 44.9 nmol/L. After 6 months, she achieved a natural conception, resulting in a live birth of a healthy infant at an estimated gestational age of 40 weeks. CONCLUSIONS: The successful treatment with Chinese Herbal Medicine for this case highlights a natural therapy to manage infertility due to ovarian insufficiency and multiple fibroids after unsuccessful IVF outcome

    Demand-driven primary energy requirements by Chinese economy 2012

    Get PDF
    This study examines demand-driven primary energy requirements of the Chinese economy in 2012. The discrepancies and inter-linking paths of demand-driven energy uses via domestic supply chains have been identified. The total embodied energy uses (EEUs) in final demand amount to 3318.69 Mtce, of which investment contributes 45.97% to the total. All manufacturing sectors account for 45.75% of the total EEUs, followed by construction for 29.43% and services for 13.69%. By tracing embodied energy fluxes starting from resource extraction to final uses, several critical industrial sectors and crucial routes starting from resource extraction to final use are extracted and ranked. To develop more appropriate policy designs for energy saving and emission reduction in China, demand-driven embodied energy uses deserve to be considered from a systematic viewpoint

    Efficient unknown tag identification protocols in large-scale RFID systems

    Get PDF
    PublishedJournal ArticleOwing to its attractive features such as fast identification and relatively long interrogating range over the classical barcode systems, radio-frequency identification (RFID) technology possesses a promising prospect in many practical applications such as inventory control and supply chain management. However, unknown tags appear in RFID systems when the tagged objects are misplaced or unregistered tagged objects are moved in, which often causes huge economic losses. This paper addresses an important and challenging problem of unknown tag identification in large-scale RFID systems. The existing protocols leverage the Aloha-like schemes to distinguish the unknown tags from known tags at the slot level, which are of low time-efficiency, and thus can hardly satisfy the delay-sensitive applications. To fill in this gap, two filtering-based protocols (at the bit level) are proposed in this paper to address the problem of unknown tag identification efficiently. Theoretical analysis of the protocol parameters is performed to minimize the execution time of the proposed protocols. Extensive simulation experiments are conducted to evaluate the performance of the protocols. The results demonstrate that the proposed protocols significantly outperform the currently most promising protocols.This work was supported by NSFC (Grant Nos. 60973117, 61173160, 61173162, and 60903154), New Century Excellent Talents in University (NCET) of Ministry of Education of China, The Research Fund for the Doctoral Program of Higher Education (Program No. 20130041110019) and the National Science Foundation for Distinguished Young Scholars of China (Grant No. 61225010)

    Characterisation of Bone Beneficial Components from Australian Wallaby Bone.

    Full text link
    Background: Osteoporosis is a condition in which the bones become brittle, increasing the risk of fractures. Complementary medicines have traditionally used animal bones for managing bone disorders, such as osteoporosis. This study aimed to discover new natural products for these types of conditions by determining mineral and protein content of bone extracts derived from the Australian wallaby. Methods: Inductively coupled plasma-mass spectrometry and Fourier transform infrared spectroscopic analysis were used for mineral tests, proteome analysis was using LC/MS/MS and the effects of wallaby bone extracts (WBE)s on calcium deposition and alkaline phosphatase activity were evaluated in osteogenic cells derived from adipose tissue-derived stem cells (ADSCs). Results: Concentrations of calcium and phosphorus were 26.21% and 14.72% in WBE respectively. Additionally, minerals found were wide in variety and high in concentration, while heavy metal concentrations of aluminium, iron, zinc and other elements were at safe levels for human consumption. Proteome analysis showed that extracts contained high amounts of bone remodelling proteins, such as osteomodulin, osteopontin and osteoglycin. Furthermore, in vitro evaluation of WBEs showed increased deposition of calcium in osteoblasts with enhanced alkaline phosphatase activity in differentiated adipose-derived stem cells. Conclusion: Our results demonstrate that wallaby bone extracts possess proteins and minerals beneficial for bone metabolism. WBEs may therefore be used for developing natural products for conditions such as osteoporosis and further investigation to understand biomolecular mechanism by which WBEs prevent osteoporosis is warranted

    Design and performance evaluation of additively manufactured composite lattice structures of commercially pure Ti (CP–Ti)

    Get PDF
    Ti alloys with lattice structures are garnering more and more attention in the field of bone repair or regeneration due to their superior structural, mechanical, and biological properties. In this study, six types of composite lattice structures with different strut radius that consist of simple cubic (structure A), body-centered cubic (structure B), and edge-centered cubic (structure C) unit cells are designed. The designed structures are firstly simulated and analysed by the finite element (FE) method. Commercially pure Ti (CP–Ti) lattice structures with optimized unit cells and strut radius are then fabricated by selective laser melting (SLM), and the dimensions, microtopography, and mechanical properties are characterised. The results show that among the six types of composite lattice structures, combined BA, CA, and CB structures exhibit smaller maximum von-Mises stress, indicating that these structures have higher strength. Based on the fitting curves of stress/specific surface area versus strut radius, the optimized strut radius of BA, CA, and CB structures is 0.28, 0.23, and 0.30 mm respectively. Their corresponding compressive yield strength and compressive modulus are 42.28, 30.11, and 176.96 MPa, and 4.13, 2.16, and 7.84 GPa, respectively. The CP-Ti with CB unit structure presents a similar strength and compressive modulus to the cortical bone, which makes it a potential candidate for subchondral bone restorations

    The effect of Cu content on corrosion, wear and tribocorrosion resistance of Ti-Mo-Cu alloy for load-bearing bone implants

    Get PDF
    In this study, the effects of Cu content on wear, corrosion, and tribocorrosion resistance of Ti-10Mo-xCu alloy were investigated. Results revealed that hardness of Ti-10Mo-xCu alloy increased from 355.1 ± 15.2 HV to 390.8 ± 17.6 HV by increasing Cu content from 0 % to 5 %, much higher than CP Ti (106.6 ± 15.1 HV) and comparable to Ti64 (389.7 ± 13.9 HV). With a higher Cu content, wear and tribocorrosion resistance of Ti-10Mo-xCu alloys were enhanced, and corrosion resistance showed an initial increase with a subsequent decrease. Wear mechanisms under pure mechanical wear and tribocorrosion conditions of Ti-10Mo-xCu alloys were a combination of delamination, abrasion and adhesion wear

    Characteristics of novel Ti–10Mo-xCu alloy by powder metallurgy for potential biomedical implant applications

    Get PDF
    When biomaterials are implanted in the human body, the surfaces of the implants become favorable sites for microbial adhesion and biofilm formation, causing peri-implant infection which frequently results in the failure of prosthetics and revision surgery. Ti–Mo alloy is one of the commonly used implant materials for load-bearing bone replacement, and the prevention of infection of Ti–Mo implants is therefore crucial. In this study, bacterial inhibitory copper (Cu) was added to Ti–Mo matrix to develop a novel Ti–Mo–Cu alloy with bacterial inhibitory property. The effects of Cu content on microstructure, tensile properties, cytocompatibility, and bacterial inhibitory ability of Ti–Mo–Cu alloy were systematically investigated. Results revealed that Ti–10Mo–1Cu alloy consisted of α and β phases, while there were a few Ti_{2}Cu intermetallic compounds existed for Ti–10Mo–3Cu and Ti–10Mo–5Cu alloys, in addition to α and β phases. The tensile strength of Ti–10Mo-xCu alloy increased with Cu content while elongation decreased. Ti–10Mo–3Cu alloy exhibited an optimal tensile strength of 1098.1 MPa and elongation of 5.2%. Cytocompatibility study indicated that none of the Ti–10Mo-xCu alloys had a negative effect on MC3T3-E1 cell proliferation. Bacterial inhibitory rates against S. aureus and E. coli increased with the increase in Cu content of Ti–10Mo-xCu alloy, within the ranges of 20–60% and 15–50%, respectively. Taken together, this study suggests that Ti–10Mo–3Cu alloy with high strength, acceptable elongation, excellent cytocompatibility, and the bacterial inhibitory property is a promising candidate for biomedical implant applications
    • …
    corecore