21 research outputs found

    A Bayesian optimization tunning integrated multi-stacking classifier framework for the prediction of radiodermatitis from 4D-CT of patients underwent breast cancer radiotherapy

    Get PDF
    PurposeIn this study, we aimed to develop a novel Bayesian optimization based multi-stacking deep learning platform for the prediction of radiation-induced dermatitis (grade ≄ two) (RD 2+) before radiotherapy, by using multi-region dose-gradient-related radiomics features extracted from pre-treatment planning four-dimensional computed tomography (4D-CT) images, as well as clinical and dosimetric characteristics of breast cancer patients who underwent radiotherapy.Materials and methodsThe study retrospectively included 214 patients with breast cancer who received radiotherapy after breast surgeries. Six regions of interest (ROIs) were delineated based on three PTV dose -gradient-related and three skin dose-gradient-related parameters (i.e., isodose). A total of 4309 radiomics features extracted from these six ROIs, as well as clinical and dosimetric characteristics, were used to train and validate the prediction model using nine mainstream deep machine learning algorithms and three stacking classifiers (i.e., meta-learners). To achieve the best prediction performance, a Bayesian optimization based multi-parameter tuning technology was adopted for the AdaBoost, random forest (RF), decision tree (DT), gradient boosting (GB) and extra tree (XTree) five machine learning models. The five parameter -tuned learners and the other four learners (i.e., logistic regression (LR), K-nearest neighbors (KNN), linear discriminant analysis (LDA), Bagging) whose parameters cannot be tuned, all as the primary week learners, were fed into the subsequent meta-learners for training and learning the final prediction model.ResultsThe final prediction model included 20 radiomics features and eight clinical and dosimetric characteristics. At the primary learner level, on base of Bayesian parameter tuning optimization, the RF, XGBoost, AdaBoost, GBDT, and LGBM models with the best parameter combinations achieved AUC of 0.82, 0.82, 0.77, 0.80, and 0.80 prediction performance in the verification data set, respectively. In the secondary meta-learner lever, compared with LR and MLP meta-learner, the best predictor of symptomatic RD 2+ for stacked classifiers was the GB meta-learner with an area under the curve (AUC) of 0.97 [95% CI: 0.91-1.0] and an AUC of 0.93 [95% CI: 0.87-0.97] in the training and validation datasets, respectively and the 10 top predictive characteristics were identified.ConclusionA novel multi-region dose-gradient-based Bayesian optimization tunning integrated multi-stacking classifier framework can achieve a high-accuracy prediction of symptomatic RD 2+ in breast cancer patients than any other single deep machine learning algorithm

    Mixed Effect Modeling of Dose and Linear Energy Transfer Correlations With Brain Image Changes After Intensity Modulated Proton Therapy for Skull Base Head and Neck Cancer

    Get PDF
    Purpose Intensity modulated proton therapy (IMPT) could yield high linear energy transfer (LET) in critical structures and increased biological effect. For head and neck cancers at the skull base this could potentially result in radiation-associated brain image change (RAIC). The purpose of the current study was to investigate voxel-wise dose and LET correlations with RAIC after IMPT. Methods and Materials For 15 patients with RAIC after IMPT, contrast enhancement observed on T1-weighted magnetic resonance imaging was contoured and coregistered to the planning computed tomography. Monte Carlo calculated dose and dose-averaged LET (LETd) distributions were extracted at voxel level and associations with RAIC were modelled using uni- and multivariate mixed effect logistic regression. Model performance was evaluated using the area under the receiver operating characteristic curve and precision-recall curve. Results An overall statistically significant RAIC association with dose and LETd was found in both the uni- and multivariate analysis. Patient heterogeneity was considerable, with standard deviation of the random effects of 1.81 (1.30-2.72) for dose and 2.68 (1.93-4.93) for LETd, respectively. Area under the receiver operating characteristic curve was 0.93 and 0.95 for the univariate dose-response model and multivariate model, respectively. Analysis of the LETd effect demonstrated increased risk of RAIC with increasing LETd for the majority of patients. Estimated probability of RAIC with LETd = 1 keV/”m was 4% (95% confidence interval, 0%, 0.44%) and 29% (95% confidence interval, 0.01%, 0.92%) for 60 and 70 Gy, respectively. The TD15 were estimated to be 63.6 and 50.1 Gy with LETd equal to 2 and 5 keV/”m, respectively. Conclusions Our results suggest that the LETd effect could be of clinical significance for some patients; LETd assessment in clinical treatment plans should therefore be taken into consideration.publishedVersio

    Genome Expression Profile Analysis of the Immature Maize Embryo during Dedifferentiation

    Get PDF
    Maize is one of the most important cereal crops worldwide and one of the primary targets of genetic manipulation, which provides an excellent way to promote its production. However, the obvious difference of the dedifferentiation frequency of immature maize embryo among various genotypes indicates that its genetic transformation is dependence on genotype and immature embryo-derived undifferentiated cells. To identify important genes and metabolic pathways involved in forming of embryo-derived embryonic calli, in this study, DGE (differential gene expression) analysis was performed on stages I, II, and III of maize inbred line 18-599R and corresponding control during the process of immature embryo dedifferentiation. A total of ∌21 million cDNA tags were sequenced, and 4,849,453, 5,076,030, 4,931,339, and 5,130,573 clean tags were obtained in the libraries of the samples and the control, respectively. In comparison with the control, 251, 324 and 313 differentially expressed genes (DEGs) were identified in the three stages with more than five folds, respectively. Interestingly, it is revealed that all the DEGs are related to metabolism, cellular process, and signaling and information storage and processing functions. Particularly, the genes involved in amino acid and carbohydrate transport and metabolism, cell wall/membrane/envelope biogenesis and signal transduction mechanism have been significantly changed during the dedifferentiation. To our best knowledge, this study is the first genome-wide effort to investigate the transcriptional changes in dedifferentiation immature maize embryos and the identified DEGs can serve as a basis for further functional characterization

    A COVID-19 Risk Score Combining Chest CT Radiomics and Clinical Characteristics to Differentiate COVID-19 Pneumonia From Other Viral Pneumonias

    Get PDF
    With the continued transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) throughout the world, identification of highly suspected COVID-19 patients remains an urgent priority. In this study, we developed and validated COVID-19 risk scores to identify patients with COVID-19. In this study, for patient-wise analysis, three signatures, including the risk score using radiomic features only, the risk score using clinical factors only, and the risk score combining radiomic features and clinical variables, show an excellent performance in differentiating COVID-19 from other viral-induced pneumonias in the validation set. For lesion-wise analysis, the risk score using three radiomic features only also achieved an excellent AUC value. In contrast, the performance of 130 radiologists based on the chest CT images alone without the clinical characteristics included was moderate as compared to the risk scores developed. The risk scores depicting the correlation of CT radiomics and clinical factors with COVID-19 could be used to accurately identify patients with COVID-19, which would have clinically translatable diagnostic and therapeutic implications from a precision medicine perspective

    Optimizing the sum of linear fractional functions and applications

    Get PDF
    Proceedings of the Eleventh Annual ACM-SIAM Symposium on Discrete Algorithms, San Francisco, California, January 9-11, 2000 -- T.p. verso ; This symposium was sponsored by the ACM Special Interest Group on Algorithms and Computation Theory and the SIAM Activity Group on Discrete Mathematics.Proc. of 11th Annual ACM-SIAM Symposium on Discrete Algorithm

    Optimizing the Sum of Linear Fractional Functions and Applications

    Get PDF
    Proceedings of the Eleventh Annual ACM-SIAM Symposium on Discrete Algorithms, San Francisco, California, January 9-11, 2000 -- T.p. verso ; This symposium was sponsored by the ACM Special Interest Group on Algorithms and Computation Theory and the SIAM Activity Group on Discrete Mathematics.Proc. of 11th Annual ACM-SIAM Symposium on Discrete Algorithm

    MSPT: An open-source motion simulator for proton therapy

    No full text
    International audienceThe dosimetric benefits of proton therapy may be greatly degraded when the tumor or organs move during the treatment. Hence, mitigation or adaptive methods have become topics of research interest. These techniques require dose computation on time-dependent patient geometry. We developed an open-source 4D dose computation and evaluation software, MSPT (Motion Simulator for Proton Therapy), for the spot-scanning delivery technique. It aims at highlighting the impact of the patient motion during a treatment delivery by computing dose on the moving patient. The main interest of this simulator lies in the ability to render the impact of a predicted patient motion on a prescribed treatment plan. MSPT used proton pencil beam algorithm for dose computation, and the dose in patient geometry computed by MSPT was able to match that computed by the commercial treatment planning system. MSPT was able to render the impact of motion on patient data sets. This capability makes it an innovative research tool to evaluate and compare different methods of motion management or mitigation. The open-source feature makes it appealing, since it is intended to evolve, to be improved and to be the starting point of new research on patient motion in proton therapy
    corecore