3,531 research outputs found

    Novel Microfiber Sensor and Its Biosensing Application for Detection of hCG Based on a Singlemode-Tapered Hollow Core-Singlemode Fiber Structure

    Get PDF
    A novel microfiber sensor is proposed and demonstrated based on a singlemode-tapered hollow core -singlemode (STHS) fiber structure. Experimentally a STHS with taper waist diameter of 26.5 μm has been fabricated and RI sensitivity of 816, 1601.86, and 4775.5 nm/RIU has been achieved with RI ranges from 1.3335 to 1.3395 , from 1.369 to 1.378, and from 1.409 to 1.4175 respectively, which agrees very well with simulated RI sensitivity of 885, 1517, and 4540 nm/RIU at RI ranges from 1.3335 to 1.337, from 1.37 to 1.374, and from 1.41 to 1.414 . The taper waist diameter has impact on both temperature and strain sensitivity of the sensor structure: (1) the smaller the waist diameter, the higher the temperature sensitivity, and experimentally 26.82 pm/°C has been achieved with a taper waist diameter of 21.4 μm; (2) as waist diameter decrease, strain sensitivity increase and 7.62 pm/με has been achieved with a taper diameter of 20.3 μm. The developed sensor was then functionalized for human chorionic gonadotropin (hCG) detection as an example for biosensing application. Experimentally for hCG concentration of 5 mIU/ml, the sensor has 0.5 nm wavelength shift, equivalent to limit of detection (LOD) of 0.6 mIU/ml by defining 3 times of the wavelength variation (0.06 nm) as measurement limit. The biosensor demonstrated relatively good reproducibility and specificity, which has potential for real medical diagnostics and other applications

    Ethyl 6-methyl­sulfanyl-2-phenyl-1H-imidazo[1,2-b]pyrazole-7-carboxyl­ate monohydrate

    Get PDF
    The title compound, C15H15N3O2S·H2O, has been obtained in a search for new imidazo[1,2-b]pyrazole derivatives with better biological activity. The 1H-imidazo[1,2-b]pyrazole plane forms a dihedral angle of 16.90 (3)° with the benzene ring. π–π inter­actions are indicated by the short distance of 3.643 (2) Å between the centroids of the benzene and imidazole rings. The crystal structure also involves inter­molecular O—H⋯N hydrogen bonds

    Delivery of Berberine Using Chitosan/Fucoidan-Taurine Conjugate Nanoparticles for Treatment of Defective Intestinal Epithelial Tight Junction Barrier

    Get PDF
    [[abstract]]Bacterial-derived lipopolysaccharides (LPS) can cause defective intestinal barrier function and play an important role in the development of inflammatory bowel disease. In this study, a nanocarrier based on chitosan and fucoidan was developed for oral delivery of berberine (Ber). A sulfonated fucoidan, fucoidan-taurine (FD-Tau) conjugate, was synthesized and characterized by Fourier transform infrared (FTIR) spectroscopy. The FD-Tau conjugate was self-assembled with berberine and chitosan (CS) to form Ber-loaded CS/FD-Tau complex nanoparticles with high drug loading efficiency. Berberine release from the nanoparticles had fast release in simulated intestinal fluid (SIF, pH 7.4), while the release was slow in simulated gastric fluid (SGF, pH 2.0). The effect of the berberine-loaded nanoparticles in protecting intestinal tight-junction barrier function against nitric oxide and inflammatory cytokines released from LPS-stimulated macrophage was evaluated by determining the transepithelial electrical resistance (TEER) and paracellular permeability of a model macromolecule fluorescein isothiocyanate-dextran (FITC-dextran) in a Caco-2 cells/RAW264.7 cells co-culture system. Inhibition of redistribution of tight junction ZO-1 protein by the nanoparticles was visualized using confocal laser scanning microscopy (CLSM). The results suggest that the nanoparticles may be useful for local delivery of berberine to ameliorate LPS-induced intestinal epithelia tight junction disruption, and that the released berberine can restore barrier function in inflammatory and injured intestinal epithelial.[[notice]]補正完畢[[incitationindex]]SCI[[booktype]]電子

    1-(3-tert-Butyl-4-hy­droxy­phen­yl)ethanone

    Get PDF
    The title compound, C12H16O2, is approximately planar (r.m.s. deviation = 0.030 Å), apart from two methyl groups of the tert-butyl unit [deviations of the C atoms = 1.140 (2) and −1.367 (1) Å]. In the crystal, inter­molecular O—H⋯O hydrogen bonds link the mol­ecules into hexa­meric rings with R 6 6(48) graph-set motifs

    Field emission enhancement of Au-Si nano-particle-decorated silicon nanowires

    Get PDF
    Au-Si nano-particle-decorated silicon nanowire arrays have been fabricated by Au film deposition on silicon nanowire array substrates and then post-thermal annealing under hydrogen atmosphere. Field emission measurements illustrated that the turn-on fields of the non-annealed Au-coated SiNWs were 6.02 to 7.51 V/μm, higher than that of the as-grown silicon nanowires, which is about 5.01 V/μm. Meanwhile, after being annealed above 650°C, Au-Si nano-particles were synthesized on the top surface of the silicon nanowire arrays and the one-dimensional Au-Si nano-particle-decorated SiNWs had a much lower turn-on field, 1.95 V/μm. The results demonstrated that annealed composite silicon nanowire array-based electron field emitters may have great advantages over many other emitters

    Application Research of Crawler and Data Analysis Based on Python

    Get PDF

    Headache in the Pediatric Emergency Service: A Medical Center Experience

    Get PDF
    BackgroundHeadache is a common complaint in children and is one of the most common reasons for presentation at a pediatric emergency department (PED). This study described the etiologies of patients with headache seen in the PED and determined predictors of intracranial pathology (ICP) requiring urgent intervention. A secondary objective was to develop rapid, practical tools for screening headache in the PED.MethodsWe conducted a retrospective chart review of children who presented with a chief complaint of headache at the PED during 2008. First, we identified possible red flags in the patients' history or physical examination and neurological examination findings. Then, we recorded the brain computed tomography results.ResultsDuring the study period, 43,913 visits were made to the PED; in 409 (0.9%) patients, the chief complaint was headache. Acute viral, respiratory, and febrile illnesses comprised the most frequent cause of headache (59.9%). Six children (1.5%) had life-threatening ICP findings. In comparison with the group without ICP, the group with ICP had a significantly higher percentage of blurred vision (p = 0.008) and ataxia (p = 0.002).ConclusionBlurred vision and ataxia are the best clinical parameters to predict ICP findings

    The LAMOST Complete Spectroscopic Survey of Pointing Area (LaCoSSPAr) in the Southern Galactic Cap I. The Spectroscopic Redshift Catalog

    Full text link
    We present a spectroscopic redshift catalog from the LAMOST Complete Spectroscopic Survey of Pointing Area (LaCoSSPAr) in the Southern Galactic Cap (SGC), which is designed to observe all sources (Galactic and extra-galactic) by using repeating observations with a limiting magnitude of r=18.1 magr=18.1~mag in two 20 deg220~deg^2 fields. The project is mainly focusing on the completeness of LAMOST ExtraGAlactic Surveys (LEGAS) in the SGC, the deficiencies of source selection methods and the basic performance parameters of LAMOST telescope. In both fields, more than 95% of galaxies have been observed. A post-processing has been applied to LAMOST 1D spectrum to remove the majority of remaining sky background residuals. More than 10,000 spectra have been visually inspected to measure the redshift by using combinations of different emission/absorption features with uncertainty of σz/(1+z)<0.001\sigma_{z}/(1+z)<0.001. In total, there are 1528 redshifts (623 absorption and 905 emission line galaxies) in Field A and 1570 redshifts (569 absorption and 1001 emission line galaxies) in Field B have been measured. The results show that it is possible to derive redshift from low SNR galaxies with our post-processing and visual inspection. Our analysis also indicates that up to 1/4 of the input targets for a typical extra-galactic spectroscopic survey might be unreliable. The multi-wavelength data analysis shows that the majority of mid-infrared-detected absorption (91.3%) and emission line galaxies (93.3%) can be well separated by an empirical criterion of W2W3=2.4W2-W3=2.4. Meanwhile, a fainter sequence paralleled to the main population of galaxies has been witnessed both in MrM_r/W2W3W2-W3 and MM_*/W2W3W2-W3 diagrams, which could be the population of luminous dwarf galaxies but contaminated by the edge-on/highly inclined galaxies (30%\sim30\%).Comment: 19 pages, 14 figures, 2 MRT, accepted by ApJ
    corecore