23,037 research outputs found

    Spin-transfer switching and low-field precession in exchange-biased spin valve nano-pillars

    Full text link
    Using a three-dimensional focused-ion beam lithography process we have fabricated nanopillar devices which show spin transfer torque switching at zero external magnetic fields. Under a small in-plane external bias field, a field-dependent peak in the differential resistance versus current is observed similar to that reported in asymmetrical nanopillar devices. This is interpreted as evidence for the low-field excitation of spin waves which in our case is attributed to a spin-scattering asymmetry enhanced by the IrMn exchange bias layer coupled to a relatively thin CoFe fixed layer.Comment: 11 pages, 4 figures. To appear in APL, April 200

    Abnormally high content of free glucosamine residues identified in a preparation of commercially available porcine intestinal heparan sulfate

    Get PDF
    Heparan sulfate (HS) polysaccharides are ubiquitous in animal tissues as components of proteoglycans, and they participate in many important biological processes. HS carbohydrate chains are complex and can contain rare structural components such as N-unsubstituted glucosamine (GlcN). Commercially available HS preparations have been invaluable in many types of research activities. In the course of preparing microarrays to include probes derived from HS oligosaccharides, we found an unusually high content of GlcN residue in a recently purchased batch of porcine intestinal mucosal HS. Composition and sequence analysis by mass spectrometry of the oligosaccharides obtained after heparin lyase III digestion of the polysaccharide indicated two and three GlcN in the tetrasaccharide and hexasaccharide fractions, respectively. (1)H NMR of the intact polysaccharide showed that this unusual batch differed strikingly from other HS preparations obtained from bovine kidney and porcine intestine. The very high content of GlcN (30%) and low content of GlcNAc (4.2%) determined by disaccharide composition analysis indicated that N-deacetylation and/or N-desulfation may have taken place. HS is widely used by the scientific community to investigate HS structures and activities. Great care has to be taken in drawing conclusions from investigations of structural features of HS and specificities of HS interaction with proteins when commercial HS is used without further analysis. Pending the availability of a validated commercial HS reference preparation, our data may be useful to members of the scientific community who have used the present preparation in their studies

    Electrically Small, Low-Profile, Planar, Huygens Dipole Antenna with Quad-Polarization Diversity

    Full text link
    © 1963-2012 IEEE. An electrically small, low profile, planar, Huygens dipole antenna with four reconfigurable polarization states is presented. The design incorporates both electric and magnetic near-field resonant parasitic elements and a reconfigurable driven element. The four polarization states include two orthogonal linear polarized (LP) and two circular polarization (LHCP and RHCP) states. A 1.5 GHz prototype was fabricated (partially with 3-D additive manufacturing), assembled, and tested. The measured results, in good agreement with their simulated values, demonstrate that even with its simple configuration, electrically small size (ka =0.944), and low-profile height (0.0449 λ0), this reconfigurable Huygens antenna possesses stable broadside radiation performance in all of its four polarization states. The measured results demonstrate that in its x(y)-LP state, the peak realized gain, front-to-back ratio, and radiation efficiency values are, respectively, 3303 dBi (2.97 dBi), 10.7 dB (9.9 dB), and 68.2% (67.5%). For the LHCP (RHCP) states, they are, respectively, 2.82 dBi (2.74 dBi), 11.4 dB (12.5 dB), and 67.1% (65.9%)

    Emulsifier and antioxidant properties of by-products obtained by enzymatic degumming of soybean oil

    Get PDF
    The enzymes used in degumming, called phospholipases, specifically act on phospholipids without degrading the oil itself. Degumming using a phospholipase C enzyme allows to meet all market specifications while it increases the oil yield. The aim of this study was to evaluate antioxidant and emulsifier properties of the recovered gum (RG) obtained by enzymatic oil degumming process of crude soybean oil subjected to modifications as deoiling (RG deoiled) or ethanol fractionation (RG soluble and insoluble). RG soluble allowed obtaining more stable O/W emulsions (30:70 w/w) in comparison with those by-products assayed at different concentrations (0.1?1.0%). Also, deoiled soybean lecithin (DSL) andRG deoiled had a similar behavior in relation to the kinetic destabilization (%BS profiles), despite the different degumming processes used to obtain these samples. The study on induction times (Metrohm Rancimat) showed a significant antioxidant effect (p<0.05) against a refined sunflower oil associated with all the by-products analyzed. However, RG soluble and DSL showed a strong effect on the oil stability at high concentrations (1000?2000 ppm). These results showed that the deoiled recovered gum and its derivates obtained by ethanol fractionation are a potential alternative for industrial application as additive.Fil: Cabezas, Dario Marcelino. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Diehl, B. W. K.. Spectral Service GmbH Laboratorium fur Auftragsanalytik. Cologne; AlemaniaFil: Tomas, Mabel Cristina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentin

    Activating mechanism of transcriptor NF-kappaB regulated by hepatitis B virus X protein in hepatocellular carcinoma

    Get PDF
    Aim: To investigate the mechanism and significance of NF-κB activation regulated by hepatitis B virus X protein (HBx) in hepatitis B virus (HBV)-associated hepatocellular carcinoma (HCC). Methods: The expression levels of HBx, p65, IκB-α and ubiquitin were detected by immunohistochemistry in HCC tissue microarrays (TMA) respectively, and IκB-α was detected by Western blot in HCC and corresponding liver tissues. Results: The percentage of informative TMA samples was 98.8% in 186 cases with a total of 367 samples. Compared with corresponding liver tissues (60.0%), the HBx expression was obviously decreased in HBV-associated HCC (47.9%, u=2.24, P<0.05). On the contrary, the expressions of p65 (20.6% vs 45.3%, u=4.85, P<0.01) and ubiquitin (8.9% vs 59.0%, u=9.68, P<0.01 ) were notably elevated in HCC. In addition, IκB-α had a tendency to go up. Importantly, positive relativity was observed between HBx and p65 (χ2=10.26, P<0.01), p65 and IκB-α (χ2=16.86, P<0.01), IκB-α and ubiquitin (χ2=8.90, P<0.01) in HCC, respectively. Conclusion: Both active and non-active forms of NF-κB are increased in HBV-associated HCC. Variant HBx is the major cause of the enhancement of NF-κB activity. The activation always proceeds in nucleus and the proteasome complexes play an important role in the activation.published_or_final_versio

    Diffusion tensor-based fiber tracking in cervical spinal cord with a 3T MRI

    Get PDF
    The protocol for spinal DTI nntl tractography with high SNR and spatial resolution has been developed arid tested on G healthy subjects and 1 CSM patient in a 3T system. Fiber bundlex were traced and were found running parallel to the cervical spinal cord correlating with the neuronal anatomy in normal subjects. The FA maps showed consistent low FA region connecting all spinal levels, which corresponded lo the grey matter structure in anatomical imaging, Spinal DTI in CSM showed diffusivity increase at compression sites. The proposed diffusion eigenvector-based method was able to differentiate between λa and λr even when there was a draxtic diffusivity change at compressed regions in CSM, which may facilitate better understanding of the pathophysiology of CSM. Our results indicated that using the current imaging and post-procensing protocols, spinal DTI can fm achieved with better grey white matter contrast, high inter-subject reproducibility and diagnostic ability. © 2006 IEEE.published_or_final_versio

    The scaling of X-ray variability with luminosity in Ultra-luminous X-ray sources

    Full text link
    We investigated the relationship between the X-ray variability amplitude and X-ray luminosity for a sample of 14 bright Ultra-luminous X-ray sources (ULXs) with XMM-Newton/EPIC data, and compare it with the well established similar relationship for Active Galactic Nuclei (AGN). We computed the normalised excess variance in the 2-10 keV light curves of these objects and their 2-10 keV band intrinsic luminosity. We also determined model "variability-luminosity" relationships for AGN, under several assumptions regarding their power-spectral shape. We compared these model predictions at low luminosities with the ULX data. The variability amplitude of the ULXs is significantly smaller than that expected from a simple extrapolation of the AGN "variability-luminosity" relationship at low luminosities. We also find evidence for an anti-correlation between the variability amplitude and L(2-10 keV) for ULXs. The shape of this relationship is consistent with the AGN data but only if the ULXs data are shifted by four orders of magnitudes in luminosity. Most (but not all) of the ULXs could be "scaled-down" version of AGN if we assume that: i) their black hole mass and accretion rate are of the order of ~(2.5-30)x 10E+03 Msolar and ~ 1-80 % of the Eddington limit, and ii) their Power Spectral Density has a doubly broken power-law shape. This PDS shape and accretion rate is consistent with Galactic black hole systems operating in their so-called "low-hard" and "very-high" states.Comment: 10 pages, 5 figures, 2 tables, accepted for publication in A&

    Study of myocardial fiber length distribution with diffusion tensor MRI

    Get PDF
    Diffusion tensor MRI (DTI) is a nondestructive method to map myocardial fiber organization. Many studies have been done on myocardial fiber orientation. However, cardiac contraction is also related with myocardial fiber length, but its study is limited so far. The current study aims to provide information of myocardial fiber length distribution in formalin-fixed porcine heart samples. DTI with medium diffusion resolution (15 directions) was performed. Fiber length distribution as a function of fiber helix angle was investigated in multiple short-axis slices located from base to apex of the left ventricles. Results show that longer fibers likely run circumferentially, and fibers located at middle and upper ventricle are generally longer than those near apex. The results provide supplementary structural information on myocardial fiber architecture and cardiac mechanics.published_or_final_versio

    Pattern reconfigurable, vertically polarized, low-profile, compact, near-field resonant parasitic antenna

    Full text link
    © 1963-2012 IEEE. A vertically polarized, low-profile, compact, near-field resonant parasitic antenna with pattern reconfigurability is demonstrated. The antenna has three dynamic end-fire states facilitated with only three p-i-n diodes. The radiation pattern in each state covers more than 120° in its azimuth plane and, hence, it achieves beam scanning that covers the entire azimuth plane. The antenna height and transverse size are, respectively, only 0.048λ 0 and 0.1λ 02 . Measured results, in good agreement with their simulated values, demonstrate that the antenna exhibits a 11% fractional impedance bandwidth, and a 6.6 dBi peak realized gain in all three of its pattern-reconfigurable states. Stable and high peak realized gain values are realized over its entire operational band surrounding 2.22 GHz

    A PC-based system for long-term monitoring of animal activity

    Get PDF
    This paper describes a PC-based animal locomotor and sound activities synchronous analysis and recording system. In the former, using video recording and image analysis techniques, the geometric locations of an animal in a cage and its bodily displacement areas between consecutive time in two-dimensions were detected. Tremendous data reduction rate has also been obtained (512×512:4), which facilitates our PC computer (Pentium 100) to perform a long-term (up to several weeks according to the space of hard disk) and on-line (1 sec) analysis and storage of the animal locomotor signals. In the latter, the sounds generated by the animal were recorded at the cage over a consecutive 1-sec time and its root mean square (RMS) value was used to index the sound level. Our preliminary study showed that such a combination of monitoring and recording system gives a faithful and comprehensive representation of animal activity.published_or_final_versio
    corecore