    Materials processing in low gravity

    Get PDF
    The final report of the Materials Processing in Low Gravity Program in which The University of Alabama in Huntsville designed, fabricated and performed various low gravity experiments in materials processing from November 7, 1989 through November 6, 1990 is presented. The facilities used in these short duration low gravity experiments include the Drop Tube and Drop Tower at Marshall Space Flight Center (MSFC), and the KC-135 aircraft at Ellington Field. During the performance of this contract, the utilization of these ground-based low gravity facilities for materials processing experiments have been instrumental in providing the opportunity to determine the feasibility of performing a number of experiments in the microgravity of Space, without the expense of a space-based experiment. Since the KC-135 was out for repairs during the latter part of the reporting period, a number of the KC-135 activities concentrated on repair and maintenance of the equipment that normally is flown on the aircraft. A number of periodic reports were given to the TCOR during the course of this contract, hence this final report is meant only to summarize the many activities performed and not redundantly cover materials already submitted

    Optical studies in the holographic ground station

    Get PDF
    The Holographic Group System (HGS) Facility in rooms 22 & 123, Building 4708 has been developed to provide for ground based research in determining pre-flight parameters and analyzing the results from space experiments. The University of Alabama, Huntsville (UAH) has researched the analysis aspects of the HGS and reports their findings here. Some of the results presented here also occur in the Facility Operating Procedure (FOP), which contains instructions for power up, operation, and powerdown of the Fluid Experiment System (FES) Holographic Ground System (HGS) Test Facility for the purpose of optically recording fluid and/or crystal behavior in a test article during ground based testing through the construction of holograms and recording of videotape. The alignment of the optical bench components, holographic reconstruction and and microscopy alignment sections were also included in the document for continuity even though they are not used until after optical recording of the test article) setup of support subsystems and the Automated Holography System (AHS) computer. The HGS provides optical recording and monitoring during GCEL runs or development testing of potential FES flight hardware or software. This recording/monitoring can be via 70mm holographic film, standard videotape, or digitized images on computer disk. All optical bench functions necessary to construct holograms will be under the control of the AHS personal computer (PC). These include type of exposure, time intervals between exposures, exposure length, film frame identification, film advancement, film platen evacuation and repressurization, light source diffuser introduction, and control of realtime video monitoring. The completed sequence of hologram types (single exposure, diffuse double exposure, etc.) and their time of occurrence can be displayed, printed, or stored on floppy disk posttest for the user

    High temperature materials characterization

    Get PDF
    A lab facility for measuring elastic moduli up to 1700 C was constructed and delivered. It was shown that the ultrasonic method can be used to determine elastic constants of materials from room temperature to their melting points. The ease in coupling high frequency acoustic energy is still a difficult task. Even now, new coupling materials and higher power ultrasonic pulsers are being suggested. The surface was only scratched in terms of showing the full capabilities of either technique used, especially since there is such a large learning curve in developing proper methodologies to take measurements into the high temperature region. The laser acoustic system does not seem to have sufficient precision at this time to replace the normal buffer rod methodology

    Photolysis of spacecraft contaminants

    Get PDF
    A molecular beam facility, which was designed to measure photochemical cross-sections, has been constructed at the Athens College science facility. The integration of this vacuum system into an operational photochemical instrument was performed with signal processing consisting of both dc and ac techniques. Of the experiments performed to date on the vacuum ultraviolet photolysis of water vapor, it is apparent that a larger pumping capacity (preferably with differential pumping) is required to improve upon the background signal. Both phase-sensitive detection and ion-counting techniques are recommended for future studies

    Automated eddy current analysis of materials

    Get PDF
    The use of eddy current techniques for characterizing flaws in graphite-based filament-wound cylindrical structures is described. A major emphasis was also placed upon incorporating artificial intelligence techniques into the signal analysis portion of the inspection process. Developing an eddy current scanning system using a commercial robot for inspecting graphite structures (and others) was a goal in the overall concept and is essential for the final implementation for the expert systems interpretation. Manual scans, as performed in the preliminary work here, do not provide sufficiently reproducible eddy current signatures to be easily built into a real time expert system. The expert systems approach to eddy current signal analysis requires that a suitable knowledge base exist in which correct decisions as to the nature of a flaw can be performed. A robotic workcell using eddy current transducers for the inspection of carbon filament materials with improved sensitivity was developed. Improved coupling efficiencies achieved with the E-probes and horseshoe probes are exceptional for graphite fibers. The eddy current supervisory system and expert system was partially developed on a MacIvory system. Continued utilization of finite element models for predetermining eddy current signals was shown to be useful in this work, both for understanding how electromagnetic fields interact with graphite fibers, and also for use in determining how to develop the knowledge base. Sufficient data was taken to indicate that the E-probe and the horseshoe probe can be useful eddy current transducers for inspecting graphite fiber components. The lacking component at this time is a large enough probe to have sensitivity in both the far and near field of a thick graphite epoxy component

    E2/M1 ratio from the Mainz p(γ,p)π0p(\vec \gamma, p)\pi^0 data

    Full text link
    We suggest that the error quoted in the Mainz determination of the E2/M1 ratio (at the resonance energy) should be enlarged. A term dropped in expressions used by this group could be significant.Comment: 2 pages of text. Submitted to the Comments section of PR